Purpose: Since the introduction of catheter ablation as a mainstream treatment for atrial fibrillation (AF), several technical improvements have been put forward. In this contest, Ablation Index (AI) is an accurate ablation quality marker by incorporating power, delivery time, contact force (CF), and catheter stability in a weighted formula. The aim of our study is to evaluate the efficacy of AI-guided AF ablation over 24 month follow-up.
View Article and Find Full Text PDFElectrophysiology procedures are traditionally performed under fluoroscopic guidance. Nowadays a growing interest in the radiation risk associated to these procedures has been cultivated, since radiation exposure has non-negligible stochastic and deterministic effects on health. A correlation between radiation exposure and lifetime malignancy effect is difficult to establish and the threshold of a completely safe exposure dose is unknown.
View Article and Find Full Text PDFDuring the past years, endomyocardial biopsy (EMB) has gradually spread into clinical practice. However, the role of EMB in the diagnosis and treatment of cardiovascular diseases remains a controversial issue, especially in the setting of unexplained ventricular arrhythmias. Areas covered: This review describes the methodology of EMB guided by combined use of three-dimensional electroanatomical mapping systems and intracardiac echo and summarizes the classical, fluoroscopy-guided EMB technique.
View Article and Find Full Text PDFElectrical storm (ES) is a clinical condition characterized by three or more ventricular arrhythmia episodes leading to appropriate implantable cardioverter-defibrillator (ICD) therapies in a 24 h period. Mostly, arrhythmias responsible of ES are multiple morphologies of monomorphic ventricular tachycardia (VT), but polymorphic VT and ventricular fibrillation can also result in ES. Clinical presentation is very dramatic in most cases, strictly related to the cardiac disease that may worsen electrical and hemodynamic decompensation.
View Article and Find Full Text PDFElectrophysiology procedures involving left atrium navigation are becoming more frequent, mostly due to the increase of atrial fibrillation ablation. Mapping catheters of different shapes and size as well as dedicated sheaths are mandatory tools for the accomplishment of procedural end point. Therefore, technical issues are expected, usually unrelated to significant risk.
View Article and Find Full Text PDFMost of interventional procedures in cardiology are carried out under fluoroscopic imaging guidance. Besides other peri-interventional risks, radiation exposure should be considered for its stochastic (inducing malignancy) and deterministic effects on health (tissue reactions like erythema, hair loss and cataracts). In this article we analized the radiation risk from cardiovascular imaging to both patients and medical staff and discusses how customize the X-ray system and how to implement shielding measures in the cath lab.
View Article and Find Full Text PDFPurpose: Contact with cardiac tissue is a determinant of lesion efficacy during atrial fibrillation (AF) ablation. The Sensei®X Robotic Catheter System (Hansen Medical, CA) has been validated for contact force sensing. The electrical coupling index (ECI) from the EnSite Contact™ system (St.
View Article and Find Full Text PDFBackground And Aim Of The Study: The surgical segments of aortic valve leaflets from patients with severe chronic aortic regurgitation were analyzed (by percentage and structure) for their content of complex polysaccharides and glycosaminoglycans (GAGs), and compared with control segments.
Methods: The GAG, hyaluronic acid (HA), chondroitin sulfate (CS) and dermatan sulfate (DS) and disaccharide contents were determined in segments (leaflet, root attachment region and belly) of aortic valve leaflets (non-coronary, left coronary and right coronary) using a multi-analytical approach.
Results: The aortic valve leaflets showed the presence of HA and CS/DS, with an overall charge density of -0.