Strahlenther Onkol
March 2022
Purpose: To develop an automated treatment planning approach for whole breast irradiation with simultaneous integrated boost using an automated hybrid VMAT class solution (HVMAT).
Materials And Methods: Twenty-five consecutive patients with left breast cancer received 50 Gy (2 Gy/fraction) to the whole breast and an additional simultaneous 10 Gy (2.4 Gy/fraction) to the tumor cavity.
Background: In radiation oncology, automation of treatment planning has reported the potential to improve plan quality and increase planning efficiency. We performed a comprehensive dosimetric evaluation of the new Personalized algorithm implemented in Pinnacle for full planning automation of VMAT prostate cancer treatments.
Material And Methods: Thirteen low-risk prostate (without lymph-nodes irradiation) and 13 high-risk prostate (with lymph-nodes irradiation) treatments were retrospectively taken from our clinical database and re-optimized using two different automated engines implemented in the Pinnacle treatment system.
Postmastectomy radiotherapy (PMRT) has been shown to improve the overall survival for invasive breast cancer patients. However, it represents a challenging treatment geometry and individualized planning strategies with complex field arrangements are usually adopted to decrease radiotoxicity to heart and lungs. Automated treatment planning has the potential to improve plan quality consistency and planning efficiency.
View Article and Find Full Text PDF