Mesocarb metabolism in humans is the target of this investigation. A high-performance liquid chromatographic (LC) method with electrospray ionization (ESI)-ion trap mass spectrometric (MS) detection ion trap "SL" for the simultaneous determination of mesocarb and its metabolites in plasma and urine is developed and validated. Ten metabolites and the parent drug are detected in human urine, and only four in human plasma, after the administration of a single oral dose of 10 mg of mesocarb (Sydnocarb, two 5-mg tablets).
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
February 2004
A method is described for the determination of metabolites of mesocarb in human urine by combining gradient liquid chromatography and electrospray ionization (ESI)-ion trap mass spectrometry. Seven metabolites (two isomers of hydroxymesocarb, p-hydroxymesocarb, two isomers of dihydroxymesocarb and two isomers of trihydroxymesocarb) and parent drug were detected in human urine after the administration of a single oral dose 10 mg of mesocarb (Sydnocarb, two tablets of 5 mg). Various extraction techniques (free fraction, enzyme hydrolyses and acid hydrolyses) and their comparison were carried out for investigation of the metabolism of mesocarb.
View Article and Find Full Text PDF