Unlabelled: The use of standard concentrations of intravenous infusions has been advocated by international organisations to increase intravenous medication safety in paediatric and neonatal critical care. However, there is no guidance on how to identify and implement these infusions leading to great interunit variability.

Objective: To identify the most appropriate clinical concentrations required by our paediatric intensive care unit (PICU) population with regard to accuracy of delivery and overall fluid allowance.

View Article and Find Full Text PDF

Objective: To evaluate safety, following introduction of standard concentrations of morphine infusions in paediatric critical care.

Methods: Implementation: A multidisciplinary team was convened, and several workstreams designated, including derivation of concentrations, manufacturing, supply, prescribing, administration using smart pump technology, training and evaluation. Safety Evaluation: Retrieval of all existing data on medication errors linked to morphine use using our hospital incident reporting system and risk assessment of errors in relation to standard concentration implementation.

View Article and Find Full Text PDF

Objective: To investigate the accuracy of morphine infusions prepared for neonates in relation to the label strength and to identify the differences in deviation between infusions made in neonatal intensive care unit (NICU) and those dispensed ready-to-use from pharmacy.

Methods: Unused portions of morphine solution for infusion were collected over a 6-weeks period and used to determine the concentration of the drug by high-performance liquid chromatography (HPLC).

Results: A total of 19.