Background: Amiodarone is an anti-arrhythmic drug that has extensive tissue distribution and substantial storage in the fat tissue. Different studies have described some implications of body fat composition in its pharmacokinetics and pharmacodynamics. However, no clinical studies have described its implications for clinical efficacy.
View Article and Find Full Text PDFAnalysis of the spatio-temporal distribution of calcium sparks showed a preferential increase in sparks near the sarcolemma in atrial myocytes from patients with atrial fibrillation (AF), linked to higher ryanodine receptor (RyR2) phosphorylation at s2808 and lower calsequestrin-2 levels. Mathematical modeling, incorporating modulation of RyR2 gating, showed that only the observed combinations of RyR2 phosphorylation and calsequestrin-2 levels can account for the spatio-temporal distribution of sparks in patients with and without AF. Furthermore, we demonstrate that preferential calcium release near the sarcolemma is key to a higher incidence and amplitude of afterdepolarizations in atrial myocytes from patients with AF.
View Article and Find Full Text PDFAims: To determine the spectral dynamics of early spontaneous polymorphic ventricular tachycardia and ventricular fibrillation (PVT/VF) in humans.
Methods And Results: Fifty-eight self-terminated and 173 shock-terminated episodes of spontaneously initiated PVT/VF recorded by Medtronic implanted cardiac defibrillators (ICDs) in 87 patients with various cardiac pathologies were analyzed by short fast Fourier transform of shifting segments to determine the dynamics of dominant frequency (DF) and regularity index (RI). The progression in the intensity of DF and RI accumulations further quantified the time course of spectral characteristics of the episodes.
Recurrence of atrial fibrillation (AF) despite successful isolation of the pulmonary veins (PVs) represents a great challenge. We present a patient with recurrent episodes of paroxysmal AF despite PV isolation in which a non-PV trigger was identified in the inferior vena cava. ().
View Article and Find Full Text PDFAims: Despite advances in interventional treatment strategies, atrial fibrillation (AF) remains associated with significant morbidity and mortality. Fibrotic atrial myopathy (FAM) is a main factor for adverse outcomes of AF-ablation, but complex to diagnose using current methods. We aimed to derive a scoring system based entirely on easily available clinical parameters to predict FAM and ablation-success in everyday care.
View Article and Find Full Text PDFBackground: The European Heart Rhythm Association (EHRA) score is a proven and validated tool for assessing the symptoms of atrial fibrillation (AF). Little is known about the variables related to this score and how it changes after cardioversion.
Methods: We analyzed 744 patients undergoing elective cardioversion in whom AF-related symptoms were assessed at baseline and after 6 months of follow-up using the EHRA score.
Background: Antiarrhythmic drugs (AADs) are frequently initiated in patients with persistent atrial fibrillation (AF) prior to electrical cardioversion (ECV), achieving pharmacological cardioversion (PCV) in some cases. Little is known about the mode of cardioversion and the effect of the type of AAD used in the maintenance of sinus rhythm (SR).
Methods: From three national surveys of patients with persistent AF referred for ECV, we selected those who were pre-treated with AADs (amiodarone or group Ic AADs).
Background: The assessment of noninvasive markers of left atrial (LA) low-voltage substrate (LVS) enables the identification of atrial fibrillation (AF) patients at risk for arrhythmia recurrence after pulmonary vein isolation (PVI).
Methods: In this prospective multicenter study, 292 consecutive AF patients (72% male, 62 ± 11 years, 65% persistent AF) underwent high-density LA voltage mapping in sinus rhythm. LA-LVS (<0.
We describe through a clinical case some of the challenges we can face when remotely monitoring a patient with two devices. The case describes a patient with two leadless pacemaker in which data transmission by remote monitoring has been achieved.
View Article and Find Full Text PDFObjectives: The study goal was to examine whether there are sex-related differences in the incidence of ventricular arrhythmias and mortality in CRT-defibrillator (CRT-D) recipients.
Background: Few studies have evaluated sex-related benefits of cardiac resynchronization therapy (CRT). Moreover, data on sex-related differences in the occurrence of ventricular tachyarrhythmias in this population are limited.
Background Large-scale studies describing modern populations using an implantable cardioverter-defibrillator (ICD) are lacking. We aimed to analyze the incidence of arrhythmia, device interventions, and mortality in a broad spectrum of real-world ICD patients with different heart disorders. Methods and Results The UMBRELLA study is a prospective, multicenter, nationwide study of contemporary patients using an ICD followed up by remote monitoring, with a blinded review of arrhythmic episodes.
View Article and Find Full Text PDFBackground: The number of implantable cardioverter defibrillator (ICD) infections is increasing due to an increased number of ICD implants, higher-risk patients, and more frequent replacement procedures, which carry a higher risk of infection. Reducing the morbidity, mortality, and cost of ICD-related infections requires an understanding of the current rate of this complication and its predictors.
Methods: The hock ant valuation Trial (SIMPLE) trial randomized 2500 ICD recipients to defibrillation testing or not.
J Interv Card Electrophysiol
October 2021
Introduction: The clinical impact of slow ventricular tachycardia (VT), occurring in patients carrying implantable cardiac defibrillators (ICD), is still under debate.
Methods And Results: From the UMBRELLA registry (multicenter, observational, and prospective study on patients with ICD), 659 episodes of slow VT were observed in 97 patients. Untreated slow VT (n = 93) had longer duration (23.
Introduction And Objectives: The ADVANCE III trial showed that a delayed-detection strategy reduces implantable cardioverter-defibrillator (ICD) therapies. Here, we describe the adherence to and predictors of ADVANCE adoption and compare ICD therapy rates between patients with and without ADVANCE programming.
Methods: This observational retrospective study analyzed patients implanted with Medtronic ICDs included from 2005 to 2016 in a Spanish national multicenter registry (UMBRELLA database; ClinicalTrials.
Purpose: The usefulness and mechanisms of antiarrhythmic drug (AAD) pre-treatment as a facilitator of the acute success of electrical cardioversion (ECV) in atrial fibrillation (AF) remain controversial. We sought to analyze the role of AAD treatment with this purpose, differentiating its possible utility either facilitating the restoration of sinus rhythm (SR) or reducing immediate AF recurrences (IAFR).
Methods: We analyzed 2962 consecutive patients with persistent AF undergoing ECV prospectively included in 3 national registries.
Aims: Atrial electrical remodelling (AER) is a transitional period associated with the progression and long-term maintenance of atrial fibrillation (AF). We aimed to study the progression of AER in individual patients with implantable devices and AF episodes.
Methods And Results: Observational multicentre study (51 centres) including 4618 patients with implantable cardioverter-defibrillator +/-resynchronization therapy (ICD/CRT-D) and 352 patients (2 centres) with pacemakers (median follow-up: 3.
Aims: Concerns about the prognostic value of NYHA functional class (FC) in heart failure (HF) patients carrying a prophylactic implantable cardioverter defibrillator (ICD) are still present. We aimed to compare whether mortality and arrhythmic risk were different, in a cohort of HF patients undergoing ICD-only implant, according to their FC.
Methods And Results: HF patients with left ventricle ejection fraction (LVEF) ≤35%, undergoing first prophylactic ICD-only implant were collected from a multicentre nationwide registry (2006-2015).
Introduction And Objectives: The Micra transcatheter pacing system has shown high effectiveness and a lower complication rate than conventional transvenous pacemakers. However, the benefit of the device is unknown in the very old population (≥ 90 years). The aim of this study was to evaluate the safety and effectiveness of Micra in patients ≥ 90 years.
View Article and Find Full Text PDFOur aim was to describe the clinical profile of patients presenting sustained ventricular arrhythmias after sacubitril/valsartan (SV) initiation. All cases of sustained ventricular arrhythmias in patients receiving SV were consecutively recorded in two centers. Nineteen patients had sustained ventricular arrhythmias after SV.
View Article and Find Full Text PDFIntroduction: Recurrences after atrial fibrillation (AF) ablation are still common. Among the reported clinical and imaging predictors of recurrences, diagnosis-to-ablation time (DAT) has been defined as a predictor of ablation outcome in single-center studies. We aimed to validate DAT in a multicenter real-life cohort.
View Article and Find Full Text PDFIntroduction: Dual-coil leads (DC-leads) were the standard of choice since the first nonthoracotomy implantable cardioverter/defibrillator (ICD). We used contemporary data to determine if DC-leads offer any advantage over single-coil leads (SC-leads), in terms of defibrillation efficacy, safety, clinical outcome, and complication rates.
Methods And Results: In the Shockless IMPLant Evaluation study, 2500 patients received a first implanted ICD and were randomized to implantation with or without defibrillation testing.