Publications by authors named "Vinod Vijan"

Adverse cardiovascular (CV) events have declined in Western countries due at least in part to aggressive risk factor control, including dyslipidemia management. The American and European (Western) dyslipidemia treatment guidelines have contributed significantly to the reduction in atherosclerotic cardiovascular disease (ASCVD) incidence in the respective populations. However, their direct extrapolation to Indian patients does not seem appropriate for the reasons described below.

View Article and Find Full Text PDF

Effective lipid management is crucial for preventing atherosclerotic cardiovascular disease (ASCVD). The Western lipid guidelines may not apply to Indian subjects because of the vast differences in cardiovascular (CV) disease epidemiology. To overcome this challenge, the Lipid Association of India (LAI) in 2016 proposed an ASCVD risk stratification algorithm.

View Article and Find Full Text PDF

Introduction: This pooled analysis was conducted to assess the clinical safety and performance of the Supra family (Sahajanand Medical Technologies Ltd., Surat, India) of sirolimus-eluting stents (SES) in patients with acute coronary syndromes (ACSs) including ST-segment elevation myocardial infarction (STEMI) from two real-world all-comers Indian registries at 1 year.

Methods: We evaluated 1,824 patients with ACS who underwent percutaneous coronary intervention with the Supra family of SES from two real-world Indian registries (891 patients from T-Flex registry and 933 patients from Tetriflex real-world registry).

View Article and Find Full Text PDF
Article Synopsis
  • The Lipid Association of India updated its cardiovascular risk assessment algorithm to address the unique challenges of atherosclerotic cardiovascular disease (ASCVD) in Indians, focusing on early intervention.
  • A series of expert meetings were held to review current evidence and refine treatment guidelines, emphasizing the need for aggressive preventive measures due to the young age of onset for ASCVD in the Indian population.
  • The updated recommendations aim to enhance LDL-C-lowering therapy and improve risk management strategies for individuals at high risk of ASCVD, ultimately striving to reduce its prevalence in India and beyond.
View Article and Find Full Text PDF

Background Despite significant evolution in stent technology, female gender, and patients with diabetes mellitus, multivessel disease, total occlusions, long lesions, and small vessels represent the "Achilles' heel" of contemporary percutaneous coronary intervention (PCI). We performed a pooled analysis of high-risk subgroup on patient-level data from the T-Flex registry (1,203 patients) and a real-world Indian registry (1,269 patients), with the aim of assessing one-year safety and clinical performance of ultrathin strut biodegradable polymer-coated Supra family of sirolimus-eluting stents (SES) (Sahajanand Medical Technologies Limited, Surat, India) in the real-world, all-comer population. Method We pooled the following high-risk subgroups data from two all-comer registries: female gender (n=678), diabetes mellitus (n=852), multivessel disease (n=406), total occlusions (n=420), long lesions (≥28 mm) (n=1241), and small vessels (≤2.

View Article and Find Full Text PDF

Purpose: Although the field of interventional cardiology has witnessed extraordinary progression, the search of an ideal coronary drug-eluting stent is still going on. Tetriflex (Sahajanand Medical Technologies Limited, Surat, India) is a latest generation biodegradable polymer-coated ultrathin (60 µm) sirolimus-eluting stent (SES) with unique Long Dual Z-link (LDZ) design. The present registry reports the 12 months clinical follow-up results of Tetriflex SES in unselected, real-world patients with coronary artery disease (CAD).

View Article and Find Full Text PDF

Objective: Lipoprotein(a) (Lp(a)) is an important genetically determined risk factor for atherosclerotic vascular disease (ASCVD). With the development of Lp(a)-lowering therapies, this study sought to characterise patterns of Lp(a) levels in a global ASCVD population and identify racial, ethnic, regional and gender differences.

Methods: A multicentre cross-sectional epidemiological study to estimate the prevalence of elevated Lp(a) in patients with a history of myocardial infarction, ischaemic stroke or peripheral artery disease conducted at 949 sites in 48 countries in North America, Europe, Asia, South America, South Africa and Australia between April 2019 and July 2021.

View Article and Find Full Text PDF

Background: Although a number of drug-eluting stents have been developed with different design, composition, and polymers, the search for an ideal drug-eluting stent is ongoing. The Tetriflex (Sahajanand Medical Technology, Surat, India) is a newer-generation, ultrathin (60 µm) biodegradable polymer-coated sirolimus-eluting stent (SES) designed with a unique long dual Z-link on a cobalt-chromium alloy. The present registry aimed to evaluate the safety and clinical outcomes of the Tetriflex SES at 6-month post-implantation.

View Article and Find Full Text PDF

Our previous research found seven specific factors that cause system delays in ST-elevation Myocardial infarction management in developing countries. These delays, in conjunction with a lack of organized STEMI systems of care, result in inefficient processes to treat AMI in developing countries. In our present opinion paper, we have specifically explored the three most pertinent causes that afflict the seven specific factors responsible for system delays.

View Article and Find Full Text PDF