Background: Pulsed field ablation (PFA) and very high-power short-duration (vHPSD) radiofrequency ablation are the most recently introduced technologies for atrial fibrillation (AF) ablation. The procedural performance, safety, and effectiveness of PFA vs vHPSD are currently unknown.
Objective: The study aimed to compare PFA with vHPSD for the treatment of paroxysmal or persistent AF.
Background: Intracardiac echocardiography (ICE) is increasingly employed in atrial fibrillation (AF) ablation procedures, with the potential to enhance procedural efficacy. Nevertheless, there is currently a lack of evidence assessing the impact of ICE on the efficiency, effectiveness, and safety outcomes in the context of novel pulsed-field ablation (PFA) for AF.
Purpose: We aimed to assess whether the use of ICE could improve procedural parameters in a large population undergoing AF ablation with FARAPULSE™ catheter.
Background: Criteria such as electrograms voltage or late potentials have been largely utilized in the past to help identify areas of substrate maps that are within the ventricular tachycardia (VT) isthmus; yet their specificity and positive predictive value are quite low. The Lumipoint fractionation tool of the Rhythmia system illuminates regions with fractionated electrograms irrespective of their timing and annotation. We aimed to ascertain whether the use of this tool can rapidly identify areas within VT isthmuses from substrate maps.
View Article and Find Full Text PDFRadiofrequency catheter ablation of the cavotricuspid isthmus is the standard treatment for patients suffering from typical atrial flutter. The aim of this study was to test the feasibility of tissue thickness and lesion transmurality measurement by a novel dielectric system. This was a retrospective multicentric non-randomized open-label, single-arm study.
View Article and Find Full Text PDFBackground: Contact force (CF)-sensing catheters have not proved superior to standard catheters in the ablation of premature ventricular contractions (PVCs) from the right and left ventricular outflow tract (RVOT, LVOT). In this context, the utility of measuring local impedance (LI) is not known. We aimed to ascertain whether the use of a catheter combining LI and CF information was associated with superior outcomes in comparison with other catheter technologies.
View Article and Find Full Text PDFBackground: The very high-power short-duration (vHPSD) temperature-controlled ablation (vHPSD) improves the efficiency of pulmonary vein isolation (PVI) procedures. We evaluated the procedural and 12-months outcomes in atrial fibrillation (AF) patients undergoing PVI by means of vHPSD ablation. In patients with AF or atrial tachyarrythmia (AT) recurrence undergoing a redo procedure the durability of the PVI was investigated.
View Article and Find Full Text PDFBackground: Reliable post-approval surveillance of implantable cardioverter-defibrillator (ICD) lead performance remains a challenge. In the past, two ICD leads were recalled due to a high frequency of failures. In this meta-analysis, we sought to provide a combined estimate of failure-free rate for ICD leads by reconstructing individual patient data from published Kaplan-Meier (KM) curves and to investigate whether estimates could be influenced by the characteristics of the study.
View Article and Find Full Text PDFBackground: Local impedance (LI) drop predicts acute conduction block during pulmonary vein isolation (PVI). Whether the LI drop predicts also the achievement of left atrial posterior wall isolation (LAPWI) in persistent atrial fibrillation (PersAF) patients is unknown. We evaluated the efficacy and the safety of LI drop-guided LAPW ablation by using high power (50 watts) and investigated the impact of ablation parameters on the LI drop.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
July 2022
Introduction: A new dielectric-based method (KODEX-EPD mapping system, EPD Solutions, a Philips company) for measuring tissue thickness at the catheter-tissue interface has recently been developed. We reported preliminarydata on real-time catheter-based measuring myocardial wall thickness in vivo, during typical atrial flutter radio frequency ablation.
Methods And Results: The study population consisted of 12 consecutive patients, suffering from symptomatic paroxysmal or persistent cavo-tricuspid isthmus dependent, counter clockwise and clockwise AFL, under going a first catheter ablation between April 2021 and November 2021.
Introduction: Low-voltage activity beyond pulmonary veins (PVs) may contribute to the failure of ablation of atrial fibrillation (AF) in the long term. We aimed to assess the presence of gaps (PVG) and residual potential (residual antral potential [RAP]) within the antral scar by means of an ultra-high-density mapping (UHDM) system.
Methods: We studied consecutive patients from the CHARISMA registry who were undergoing AF ablation and had complete characterization of residual PV antral activity.
Background: The antral region of pulmonary veins (PV)s seems to play a key role in a strategy aimed at preventing atrial fibrillation (AF) recurrence. Particularly, low-voltage activity in tissue such as the PV antra and residual potential within the antral scar likely represent vulnerabilities in antral lesion sets, and ablation of these targets seems to improve freedom from AF. The aim of this study is to validate a structured application of an approach that includes the complete abolition of any antral potential achieving electrical quiescence in antral regions.
View Article and Find Full Text PDFBackground: A very high-power short-duration (vHPSD) strategy of radiofrequency (RF) ablation aims to minimize conductive heating and increase resistive heating. We evaluated the feasibility, efficacy and safety of the vHPSD ablation of the cavotricuspid isthmus (CTI) in patients presenting with typical atrial flutter (AFL).
Methods: This prospective non-randomized study enrolled 28 consecutive patients (FAST Group) with typical AFL undergoing CTI ablation.
Purpose: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have emerged as a viable real-time indicator of tissue characteristics and the consequent durability of the lesions created. We investigated the impact of catheter-tissue contact force (CF) on LI behavior during pulmonary vein isolation (PVI).
Methods: Forty-five consecutive patients of the CHARISMA registry undergoing de novo AF radiofrequency (RF) catheter ablation with a novel open-irrigated-tip catheter endowed with CF and LI measurement capabilities (Stablepoint™ catheter, Boston Scientific) were included.
Introduction: A very high-power short-duration (vHPSD) strategy of radiofrequency (RF) ablation aims to minimize conductive heating and increase resistive heating. This study aimed to clarify the contribution of contact force (CF) and temperature and their interrelationship in making an adequate lesion with the vHPSD catheter.
Methods: We enrolled 46 consecutive patients undergoing first catheter ablation for atrial fibrillation (AF).
Pulmonary vein (PV) isolation using cryoballoon (CB) catheter is generally characterized by a high radiation and contrast media exposure. A new dielectric imaging system (KODEX-EPD imaging system) allows pulmonary vein (PV) occlusion assessment without dye use. The purpose of this study was to verify the feasibility of reducing the radiation and dye use during CB ablation in patients with atrial fibrillation (AF) using the new dielectric imaging system.
View Article and Find Full Text PDFThe association of situs inversus totalis and left ventricular noncompaction is very rare and poses several and unique challenges if endo-epicardial ablation has to be performed, both for anatomical access to the target area and for arrhythmia complexity. We report a case of incessant ventricular tachycardia with endo-epicardial involvement that required ablation in both surfaces to obtain final noninducibility.
View Article and Find Full Text PDFBackground: Current guidelines recommend avoiding apical left ventricular (LV) pacing for cardiac resynchronization therapy (CRT).
Aims: We investigated the feasibility of nonapical pacing with the current quadripolar LV lead technology.
Methods: We analyzed consecutive patients who received CRT with an LV quadripolar lead.
Aims: Ablation index (AI) is a marker of lesion quality during catheter ablation that incorporates contact force, time, and power in a weighted formula. This index was originally developed for pulmonary vein isolation as well as other left atrial procedures. The aim of our study is to evaluate the feasibility and efficacy of the AI for the ablation of the cavotricuspid isthmus (CTI) in patients presenting with typical atrial flutter (AFL).
View Article and Find Full Text PDFIntroduction: Recently, a novel technology able to measure local impedance (LI) and tissue characteristics has been made available for clinical use. This analysis explores the relationships among LI and generator impedance (GI) parameters in atrial fibrillation (AF) patients. Characterization of LI among different ablation spots and procedural success were also evaluated.
View Article and Find Full Text PDF