Publications by authors named "Vincent Jeanne"

This study presents a retrospective assessment of the diagnostic performance of the newly developed hepatitis B core-related antigen rapid diagnostic test (HBcrAg-RDT) in detecting plasma samples with elevated hepatitis B virus (HBV) DNA levels (≥200,000 IU/ml) in Yaoundé, Cameroon. Samples were collected consecutively from treatment-naïve adults living with HBV between January 1, 2021, and June 30, 2023. Analyzing 146 samples from participants with a median age of 36 years, the HBcrAg-RDT exhibited a sensitivity of 97.

View Article and Find Full Text PDF

Background & Aims: In 2020, the World Health Organization (WHO) recommended peripartum antiviral prophylaxis (PAP) for pregnant women infected with hepatitis B virus (HBV) with high viremia (≥200,000 IU/ml). Hepatitis B e antigen (HBeAg) was also recommended as an alternative when HBV DNA is unavailable. To inform policymaking and guide the implementation of prevention of mother-to-child transmission strategies, we conducted a systematic review and meta-analysis to estimate the proportion of HBV-infected pregnant women eligible for PAP at global and regional levels.

View Article and Find Full Text PDF

Objective: Economic feasibility of eliminating mother-to-child transmission (MTCT) of hepatitis B virus (HBV) in highly endemic African countries remains uncertain. Prevention of MTCT (PMTCT) involves screening pregnant women for hepatitis B surface antigen (HBsAg), identifying those with high viral loads or hepatitis B e antigen (HBeAg), and administering tenofovir prophylaxis to high-risk women. We estimated the costs of integrating PMTCT services into antenatal care in Burkina Faso, based on four different strategies to select women for tenofovir prophylaxis: (1) HBV DNA (≥200 000 IU/mL), (2) HBeAg, (3) hepatitis B core-related antigen rapid diagnostic test (HBcrAg-RDT) and (4) all HBsAg-positive women.

View Article and Find Full Text PDF

Background: Elimination of mother-to-child transmission of hepatitis B virus (HBV) requires infant immunoprophylaxis and antiviral prophylaxis for pregnant women with high viral loads. Since real-time polymerase chain reaction (RT-PCR), a gold standard for assessing antiviral eligibility, is neither accessible nor affordable for women living in low-income and middle-income countries (LMICs), rapid diagnostic tests (RDTs) detecting alternative HBV markers may be needed. To inform future development of the target product profile (TPP) for RDTs to identify highly viremic women, we used a discrete choice experiment (DCE) and elicited preference and trade-off of healthcare workers (HCW) in Africa between the following four attributes of fictional RDTs: price, time-to-result, diagnostic sensitivity, and specificity.

View Article and Find Full Text PDF

Background: Malaria continues to cause burden in various parts of the world. Haiti, a Caribbean country, is among those aiming to eliminate malaria within a few years. Two surveys were conducted in Haiti during which we aimed to evaluate the performance of the simple and rapid procedure for ultra-rapid extraction-loop-mediated isothermal amplification (PURE-LAMP) method with dried blood spots as an alternative diagnostic method for malaria in the context of low to very low rates of transmission.

View Article and Find Full Text PDF

Background: Sub-Saharan Africa is highly endemic for hepatitis B virus (HBV); historically, most people were exposed during childhood through vertical or horizontal transmission. Although all African countries now provide a three-dose infant hepatitis B vaccination starting at age 6-8 weeks, only a third of African countries have introduced birth dose (HepB-BD) vaccine. Adding HepB-BD is fundamental to prevent vertical transmission, but its effectiveness in preventing horizontal transmission, compared with the three-dose infant vaccination alone, is unknown.

View Article and Find Full Text PDF

Background: Viral hepatitis causes an important global health burden. In 2016, the World Health Assembly adopted an objective to globally eliminate this as a public health threat by 2030. However, significant gaps exist between countries in their progress.

View Article and Find Full Text PDF

Background: To reduce mortality associated with hepatitis B virus (HBV) infection, timely detection of cirrhosis and early-stage hepatocellular carcinoma (HCC) is essential. In low-income countries, however, HBV-infected people have limited access to liver histopathology, a reference test. Recently, Asian studies have suggested the usefulness of an inexpensive serum biomarker called Mac-2 binding protein glycosylation isomer (M2BPGi) in staging liver fibrosis and predicting HCC in HBV-infected patients.

View Article and Find Full Text PDF
Article Synopsis
  • There is limited information on G6PD variants in Haiti, highlighting a need for relevant public health guidelines.
  • The study found significant prevalence rates for specific G6PD mutations: 35.8% for A376G and 12.2% for G202A, along with a new mutation C370T in one participant.
  • The A202 variant, which includes A376G and G202A mutations, shows a 16.6% prevalence and may affect the safety of certain medications like primaquine in individuals with G6PD deficiency.
View Article and Find Full Text PDF

To achieve global hepatitis elimination by 2030, it is critical to prevent the mother-to-child transmission (MTCT) of hepatitis B virus (HBV). Since 2009, the WHO has recommended administering hepatitis B vaccine to all neonates within 24 h of birth to prevent MTCT. However, many countries in sub-Saharan Africa only provide hepatitis B immunization at the age of 6, 10, and 14 weeks or 8, 12, and 16 weeks using a combined vaccine.

View Article and Find Full Text PDF

Limited access to nucleic acid testing (NAT) to quantify HBV DNA levels, an essential tool to determine anti-HBV treatment eligibility, represents a significant barrier to scale up HBV diagnostic services in resource-limited countries. Hepatitis B core-related antigen (HBcrAg) has the potential to become an affordable alternative because of its low cost (US$ <15/assay) and strong correlation with HBV DNA levels in treatment-naïve patients. However, the current assay requires plasma or serum.

View Article and Find Full Text PDF

Background: Malaria is one of the most important parasitic infectious diseases for which almost half of the world's population is at risk. Although several diagnostic methods are now available to detect the infection, more sensitive and applicable tests are still required in the field. The loop-mediated isothermal amplification (LAMP) method is a DNA amplification tool in which the DNA amplification can be achieved by incubation at a stable temperature.

View Article and Find Full Text PDF

We obtained 78 human blood samples from areas in Haiti with high transmission of malaria and found no drug resistance-associated mutations in Plasmodium falciparum chloroquine resistance transporter and Kelch 13 genes. We recommend maintaining chloroquine as the first-line drug for malaria in Haiti. Artemisinin-based therapy can be used as alternative therapy.

View Article and Find Full Text PDF

A microscopy-based diagnosis is the gold standard for the detection and identification of malaria parasites in a patient's blood. However, the detection of cases involving a low number of parasites and the differentiation of species sometimes requires a skilled microscopist. Although PCR-based diagnostic methods are already known to be very powerful tools, the time required to apply such methods is still much longer in comparison to traditional microscopic observation.

View Article and Find Full Text PDF

Rationale, Aims And Objectives: Design and implement a concurrent campaign of influenza immunization and tuberculosis (TB) screening for health care workers (HCWs) that can reduce the number of clinic visits for each HCW.

Method: A discrete-event simulation model was developed to support issues of resource allocation decisions in planning and operations phases.

Results: The campaign was compressed to100 days in 2010 and further compressed to 75 days in 2012 and 2013.

View Article and Find Full Text PDF

Background: Presently the heart rate is monitored in the Neonatal Intensive Care Unit with contact sensors: electrocardiogram or pulse oximetry. These techniques can cause injuries and infections, particularly in very premature infants with fragile skin. Camera based plethysmography was recently demonstrated in adults as a contactless method to determine heart rate.

View Article and Find Full Text PDF

Remote photoplethysmography (rPPG) enables contactless monitoring of the blood volume pulse using a regular camera. Recent research focused on improved motion robustness, but the proposed blind source separation techniques (BSS) in RGB color space show limited success. We present an analysis of the motion problem, from which far superior chrominance-based methods emerge.

View Article and Find Full Text PDF