J Cardiovasc Electrophysiol
January 2025
Background: Ethanol infusion into the vein of Marshall (EI-VOM) is an adjunctive therapy to pulmonary vein isolation (PVI), which improves the efficacy of persistent atrial fibrillation (AF) ablation procedures. It is unknown how EI-VOM scar formation impacts left atrium (LA) structure and function.
Objective: To characterize scar formation after EI-VOM, and its impact on LA function, by cardiac magnetic resonance (CMR).
Pacing Clin Electrophysiol
August 2023
Over the last decades, cardiac electronic implantable devices (CEID) have incorporated a myriad of technological capabilities that are not conveniently inferred by using the conventional ICHD and NBG coding systems. We propose a new coding system (i.e.
View Article and Find Full Text PDFBackground: New tools are needed to improve ventricular tachycardia (VT) substrate characterization and optimize outcomes. LI provides biophysical tissue characterization.
Objectives: The purpose of this study was to test local impedance (LI)-based mapping to predict critical ventricular tachycardia components after myocardial infarction (MI).
Background: Atrial fibrillation (AF) ablation strategy is associated with a non-negligible risk of complications and often requires repeat procedures (AF ablation track), implying repetitive exposure to procedural risk.
Objective: The purpose of this study was to develop and validate a model to estimate individualized cumulative risk of complications in patients undergoing the AF ablation track (Atrial Fibrillation TRAck Complication risK [AF-TRACK] calculator).
Methods: The model was derived from a multicenter cohort including 3762 AF ablation procedures in 2943 patients.
Background: Adequate synchronization between the passive ("E") and active ("a") left ventricular (LV) diastolic filling contributes to the efficiency of the heartbeat. E/a superposition in dual-chamber pacemaker (PM) recipients is an under-recognized phenomenon that may be corrected by shortening the atrio-ventricular interval (AVI). We aimed at establishing the prevalence of E/a superposition in PM patients and to analyze the clinical, echocardiographic, and biological impact of AVI shortening.
View Article and Find Full Text PDFObjective: To assess the arrhythmic safety profile of the adipose graft transposition procedure (AGTP) and its electrophysiological effects on post-myocardial infarction (MI) scar.
Background: Myocardial repair is a promising treatment for patients with MI. The AGTP is a cardiac reparative therapy that reduces infarct size and improves cardiac function.
Introduction: Cryoballoon ablation (CBA) has become a standard treatment for paroxysmal atrial fibrillation (PaAF) but limited data is available for outcomes in patients with persistent atrial fibrillation (PeAF). Methods: We analyzed the first 944 patients included in the Spanish Prospective Multi-center Observation Post-market Registry to compare characteristics and outcomes of patients undergoing CBA for PeAF versus PaAF. Results: A total of 944 patients (57.
View Article and Find Full Text PDFInappropriate sinus tachycardia (IST) is a common observation in patients with post-COVID-19 syndrome (PCS) but has not yet been fully described to date. To investigate the prevalence and the mechanisms underlying IST in a prospective population of PCS patients. Consecutive patients admitted to the PCS Unit between June and December 2020 with a resting sinus rhythm rate ≥ 100 bpm were prospectively enrolled in this study and further examined by an orthostatic test, 2D echocardiography, 24-h ECG monitoring (heart rate variability was a surrogate for cardiac autonomic activity), quality-of-life and exercise capacity testing, and blood sampling.
View Article and Find Full Text PDFBackground: Freezing rate of second-generation cryoballoon (CB) is a biophysical parameter that could assist pulmonary vein isolation. The aim of this study is to assess freezing rate (time to reach -30°C ([TT-30C]) as an early predictor of acute pulmonary vein isolation using the CB.
Methods: Biophysical data from CB freeze applications within a multicenter, nation-wide CB ablation registry were gathered.
Background: Catheter ablation of accessory pathways (AP) with bidirectional conduction may be challenging due to issues related to anatomical course or location.
Objective: We describe an alternative electro-anatomical mapping technique which aims at depicting the entire anatomic course of the AP from the atrial toward the ventricular insertion in order to guide catheter ablation.
Methods: Twenty consecutive patients with confirmed bidirectional AP conduction and at least one previous ablation procedure or para-Hisian location were included.
Objectives: This study sought to analyze safety and outcomes of ventricular tachycardia (VT) substrate ablation during sinus rhythm (SR), without baseline VT induction.
Background: Safety and outcomes after scar-related VT ablation during SR are not well known. Hemodynamic instability and need for electrical cardioversion can compromise safety of VT ablation procedures.
Obstructive sleep apnea-hypopnea syndrome (OSA) compromises the efficacy of atrial fibrillation (AF) control strategies. Continuous positive airway pressure (CPAP) may ameliorate arrhythmia control especially in early AF stages (new-onset AF). We investigated a practical screening strategy to determine the likelihood of CPAP indication in new-onset AF patients.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
November 2020
Background: Myocardial fibrosis is key for atrial fibrillation maintenance. We aimed to test the efficacy of ablating cardiac magnetic resonance (CMR)-detected atrial fibrosis plus pulmonary vein isolation (PVI).
Methods: This was an open-label, parallel-group, randomized, controlled trial.
Background: The diagnostic yield of 24-hour ECG Holter monitoring (24H) is currently overcome by alternative ECG monitoring techniquesand it needs to be optimized. The recognition of inter-atrial block (IAB) has emerged as a reliable indicator of patients at risk of atrial fibrillation relapses, and its role enhancing the yield of 24H is yet to be determined. We hypothesized that a presumably low yield of 24H may be ameliorated by means of incorporating the assessment for IAB.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
November 2019
A 52-year-old man was admitted due to out-hospital cardiac arrest. Recurrent ventricular fibrillation (VF) occurred under therapeutic hypothermia thereafter. Previously inadverted full pre-excitation was documented exclusively and immediately prior to 4 out of the 5 VF relapses.
View Article and Find Full Text PDFIntroduction: Recurrences after atrial fibrillation (AF) ablation are still common. Among the reported clinical and imaging predictors of recurrences, diagnosis-to-ablation time (DAT) has been defined as a predictor of ablation outcome in single-center studies. We aimed to validate DAT in a multicenter real-life cohort.
View Article and Find Full Text PDFRev Esp Cardiol (Engl Ed)
December 2019
Introduction And Objectives: We describe the results for Spain of the Second European Cardiac Resynchronization Therapy Survey (CRT-Survey II) and compare them with those of the other participating countries.
Methods: We included patients undergoing CRT device implantation between October 2015 and December 2016 in 36 participating Spanish centers. We registered the patients' baseline characteristics, implant procedure data, and short-term follow-up information until hospital discharge.
Aims: Left atrial (LA) remodelling is a key determinant of atrial fibrillation (AF) ablation outcome. Optimal methods to assess this process are scarce. LA sphericity is a shape-based parameter shown to be independently associated to procedural success.
View Article and Find Full Text PDFObjectives: The aim of this study was to analyze whether scar characterization could improve the risk stratification for life-threatening ventricular arrhythmias and sudden cardiac death (SCD).
Background: Among patients with a cardiac resynchronization therapy (CRT) indication, appropriate defibrillator (CRT-D) therapy rates are low.
Methods: Primary prevention patients with a class I indication for CRT were prospectively enrolled and assigned to CRT-D or CRT pacemaker according to physician's criteria.