Publications by authors named "Viktor Hartung"

Aim was to evaluate the influence of different quantum iterative reconstruction (QIR) levels on the image quality of femoral photon-counting CT angiographies (PCD-CTA).Ultra-high resolution PCD-CTA were obtained from both extremities of five extracorporeally-perfused cadavers using constant tube voltage and maximum radiation dose (71.2 ± 11.

View Article and Find Full Text PDF

Conservative therapy is favored over revascularization for patients with peripheral arterial disease (PAD) and intermittent claudication (IC) owing to the better long-term results. The adjunctive use of intravascular ultrasound (IVUS) significantly improves endovascular therapy. However, data on IVUS and IC is scarce.

View Article and Find Full Text PDF

Background And Aims: The aim of this study was to investigate the imaging performance and quality differences of PCD-CT in standard resolution mode (SR) versus ultra-high resolution mode (UHR) in the lower extremity runoff of dose-matched CTAs in a human cadaveric model.

Methods: Extracorporeal perfusion of the upper leg was established in one fresh-frozen human cadaver via inguinal and popliteal accesses using a peristaltic pump. Seven peripheral stents were deployed in the SFA.

View Article and Find Full Text PDF

Recent studies suggest that arthropod diversity in German forests is declining. Currently, different national programs are being developed to monitor arthropod trends and to unravel the effects of forest management on biodiversity in forests. To establish effective long-term monitoring programs, a set of drivers of arthropod diversity and composition as well as suitable species groups have to be identified.

View Article and Find Full Text PDF

Rationale And Objectives: This study aims to compare the diagnostic confidence of photon-counting detector CT angiography (PCD-CTA) depending on the used vascular reformatting kernels with digital subtraction angiography (DSA) as diagnostic reference standard in peripheral arterial occlusive disease (PAOD).

Material And Methods: In 39 patients, 45 lower extremity PCD-CTA with subsequent DSA were analyzed. Advanced PAOD (Fontaine stage 4) was ascertained in 77.

View Article and Find Full Text PDF

Vibroacoustic signalling is one of the dominant strategies of animal communication, especially in small invertebrates. Among insects, the order Hemiptera displays a staggering diversity of vibroacoustic organs and is renowned for possessing biomechanically complex elastic recoil devices such as tymbals and snapping organs that enable robust vibrational communication. However, our understanding of the evolution of hemipteran elastic recoil devices is hindered by the absence of relevant data in the phylogenetically important group known as moss bugs (Coleorrhyncha), which produce substrate-borne vibrations through an unknown mechanism.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the usability of a recently developed extracorporeally-perfused cadaver model for training the angiographic management of acute arterial diseases and periprocedural complications that may occur during endovascular therapy of the lower extremity arterial runoff.

Materials And Methods: Continuous extracorporeal perfusion was established in three fresh-frozen body donors via inguinal and infragenicular access. Using digital subtraction angiography for guidance, both arterial embolization (e.

View Article and Find Full Text PDF

This retrospective study aims to provide an intra-individual comparison of aortic CT angiographies (CTAs) using first-generation photon-counting-detector CT (PCD-CT) and third-generation energy-integrating-detector CT (EID-CT). High-pitch CTAs were performed with both scanners and equal contrast-agent protocols. EID-CT employed automatic tube voltage selection (90/100 kVp) with reference tube current of 434/350 mAs, whereas multi-energy PCD-CT scans were generated with fixed tube voltage (120 kVp), image quality level of 64, and reconstructed as 55 keV monoenergetic images.

View Article and Find Full Text PDF

Background: With the emergence of photon-counting CT, ultrahigh-resolution (UHR) imaging can be performed without dose penalty. This study aims to directly compare the image quality of UHR and standard resolution (SR) scan mode in femoral artery angiographies.

Methods: After establishing continuous extracorporeal perfusion in four fresh-frozen cadaveric specimens, photon-counting CT angiographies were performed with a radiation dose of 5 mGy and tube voltage of 120 kV in both SR and UHR mode.

View Article and Find Full Text PDF

Background And Aims: This study aims to compare the performance of first-generation dual-source photon-counting detector computed tomography (PCD-CT) to third-generation dual-source energy-integrating detector (EID-CT) regarding stent imaging in the femoral arterial runoff.

Methods: Continuous extracorporeal perfusion was established in 1 human cadaver using an inguinal and infragenicular access and peristaltic pump. Seven peripheral stents were implanted into both superior femoral arteries by means of percutaneous angioplasty.

View Article and Find Full Text PDF

Objectives: The aim of this study was to investigate potential benefits of ultra-high resolution (UHR) over standard resolution scan mode in ultra-low dose photon-counting detector CT (PCD-CT) of the lung.

Materials And Methods: Six cadaveric specimens were examined with 5 dose settings using tin prefiltration, each in UHR (120 × 0.2 mm) and standard mode (144 × 0.

View Article and Find Full Text PDF

This study evaluated the influence of different vascular reconstruction kernels on the image quality of CT angiographies of the lower extremity runoff using a 1st-generation photon-counting-detector CT (PCD-CT) compared with dose-matched examinations on a 3rd-generation energy-integrating-detector CT (EID-CT). Inducing continuous extracorporeal perfusion in a human cadaveric model, we performed CT angiographies of eight upper leg arterial runoffs with radiation dose-equivalent 120 kVp acquisition protocols (CTDI 5 mGy). Reconstructions were executed with different vascular kernels, matching the individual modulation transfer functions between scanners.

View Article and Find Full Text PDF

This study was designed to investigate the image quality of ultra-high-resolution ankle arthrography employing a photon-counting detector CT. Bilateral arthrograms were acquired in four cadaveric specimens with full-dose (10 mGy) and low-dose (3 mGy) scan protocols. Three convolution kernels with different spatial frequencies were utilized for image reconstruction (ρ; Br98: 39.

View Article and Find Full Text PDF

Purpose: To assess radiation exposure and diagnostic performance of bilateral inferior petrosal sinus sampling for the distinction of pituitary and ectopic adrenocorticotropin-dependent Cushing's syndrome.

Materials And Methods: Procedural data of bilateral inferior petrosal sinus procedures were retrospectively evaluated. The analysis included the patients' clinical and demographic data, procedural radiation exposure, and complication rates, sampling results, clinical course of the patients, and calculation of diagnostic performance data.

View Article and Find Full Text PDF

Objectives: We developed a novel human cadaveric perfusion model with continuous extracorporeal femoral perfusion suitable for performing intra-individual comparison studies, training of interventional procedures and preclinical testing of endovascular devices. Objective of this study was to introduce the techniques and evaluate the feasibility for realistic computed tomography angiography (CTA), digital subtraction angiography (DSA) including vascular interventions, and intravascular ultrasound (IVUS).

Methods: The establishment of the extracorporeal perfusion was attempted using one formalin-fixed and five fresh-frozen human cadavers.

View Article and Find Full Text PDF

Objectives: Detailed visualization of the arterial runoff is mandatory for the assessment of peripheral arterial occlusive disease. This study aims to compare the performance of a first-generation photon-counting detector computed tomography (PCD-CT) to a third-generation energy-integrating detector CT (EID-CT).

Materials And Methods: Computed tomography angiographies of 8 upper leg arterial runoffs were performed on human cadaveric models with continuous extracorporeal perfusion.

View Article and Find Full Text PDF

Cone-beam computed tomography (CBCT) has been shown to be a powerful tool for 3D imaging of the appendicular skeleton, allowing for detailed visualization of bone microarchitecture. This study was designed to compare artifacts in the presence of osteosynthetic implants between CBCT and multidetector computed tomography (MDCT) in cadaveric wrist scans. A total of 32 scan protocols with varying tube potential and current were employed: both conventional CBCT and MDCT studies were included with tube voltage ranging from 60 to 140 kVp as well as additional MDCT protocols with dedicated spectral shaping via tin prefiltration.

View Article and Find Full Text PDF

The phylogeny of true bugs (Hemiptera: Heteroptera), one of the most diverse insect groups in terms of morphology and ecology, has been the focus of attention for decades with respect to several deep nodes between the suborders of Hemiptera and the infraorders of Heteroptera. Here, we assembled a phylogenomic data set of 53 taxa and 3102 orthologous genes to investigate the phylogeny of Hemiptera-Heteroptera, and both concatenation and coalescent methods were used. A binode-control approach for data filtering was introduced to reduce the incongruence between different genes, which can improve the performance of phylogenetic reconstruction.

View Article and Find Full Text PDF

Peloridiidae are a family of small hemipterans who live and feed on bryophytes of temperate forests in some regions of the Southern Hemisphere. They are often submerged in water and would require adaptations for respiration to tolerate periods of inundation. Here we report water-repelling cuticular structures on the tergites of thorax and abdomen and on the ventral surface of tegmina in Peloridiidae.

View Article and Find Full Text PDF

Telomeric repeats are general and significant structures of eukaryotic chromosomes. However, nothing is known about the molecular structure of telomeres in the enigmatic hemipteran suborder Coleorrhyncha (moss bugs) commonly considered as the sister group to the suborder Heteroptera (true bugs). The true bugs are known to differ from the rest of the Hemiptera in that they display an inverted sequence of sex chromosome divisions in male meiosis, the so-called sex chromosome post-reduction.

View Article and Find Full Text PDF

Background: Amyotrophic lateral sclerosis (ALS) is a fatal, progressive neurodegenerative disorder, characterised by widespread white matter damage. There is growing evidence that disturbances in iron metabolism contribute to white matter alterations.

Materials & Methods: We analysed the data of susceptibility-weighted imaging (SWI) of white matter in a cohort of 27 patients with ALS and 30 healthy age-matched controls.

View Article and Find Full Text PDF

Amyotrophic lateral sclerosis (ALS) is characterized by progressive loss of upper and lower motor neurons. Advanced MRI techniques such as diffusion tensor imaging have shown great potential in capturing a common white matter pathology. However the sensitivity is variable and diffusion tensor imaging is not yet applicable to the routine clinical environment.

View Article and Find Full Text PDF

Moss bugs (Coleorrhyncha: Peloridiidae) are members of the order Hemiptera, and like many hemipterans, they have symbiotic associations with intracellular bacteria to fulfill nutritional requirements resulting from their unbalanced diet. The primary endosymbiont of the moss bugs, Candidatus Evansia muelleri, is phylogenetically related to Candidatus Carsonella ruddii and Candidatus Portiera aleyrodidarum, primary endosymbionts of psyllids and whiteflies, respectively. In this work, we report the genome of Candidatus Evansia muelleri Xc1 from Xenophyes cascus, which is the only obligate endosymbiont present in the association.

View Article and Find Full Text PDF

External and internal head structures of Coleorrhyncha, a key-taxon within the Hemiptera, are described in detail and documented using modern techniques. The main focus is on Hackeriella veitchi, but two additional representatives of the Gondwanan relict group were also examined, and also head structures of Enicocephalidae, a member of a potentially basal heteropteran lineage. Features were compared to those documented in literature for the Sternorrhyncha, Auchenorrhyncha, and Heteroptera.

View Article and Find Full Text PDF