Aim: The aim of this study was to measure and compare the output factor (OF) of a CyberKnife Robotic Radiosurgery System with eight different small field detectors and validate with Technical Report Series (TRS) report 483.
Background: Accurate dosimetry of CyberKnife system is limited due to the challenges in small field dosimetry. OF is a vital dosimetric parameter used in the photon beam modeling and any error would affect the dose calculation accuracy.
Rep Pract Oncol Radiother
August 2018
Aim: The aim of this study was to investigate the sensitivity of the trajectory log file based quality assurance to detect potential errors such as MLC positioning and gantry positioning by comparing it with EPID measurement using the most commonly used criteria of 3%/3 mm.
Materials And Methods: An in-house program was used to modified plans using information from log files, which can then be used to recalculate a new dose distribution. The recalculated dose volume histograms (DVH) were compared with the originals to assess differences in target and critical organ dose.
Organ motions during inter-fraction and intra-fraction radiotherapy introduce errors in dose delivery, irradiating excess of normal tissue, and missing target volume. Lung and heart involuntary motions cause above inaccuracies and gated dose delivery try to overcome above effects. Present work attempts a novel method to verify dynamic dose delivery using a four-dimensional (4D) phantom.
View Article and Find Full Text PDFRep Pract Oncol Radiother
February 2016
Aim: The aim of this study is to evaluate performance of ArcCHECK diode array detector for the volumetric modulated arc therapy (VMAT) patient specific quality assurance (QA). VMAT patient specific QA results were correlated with ion chamber measurement. Dose response of the ArcCHECK detector was studied.
View Article and Find Full Text PDFIn advanced, intensity-modulated external radiotherapy facility, the multileaf collimator has a decisive role in the beam modulation by creating multiple segments or dynamically varying field shapes to deliver a uniform dose distribution to the target with maximum sparing of normal tissues. The position of each MLC leaf has become more critical for intensity-modulated delivery (step-and-shoot IMRT, dynamic IMRT, and VMAT) compared to 3D CRT, where it defines only field boundaries. We analyzed the impact of the MLC positional errors on the dose distribution for volumetric-modulated arc therapy, using a 3D dosimetry system.
View Article and Find Full Text PDFThe purpose of this study was to evaluate quantitatively the patient-specific 3D dosimetry tool COMPASS with 2D array MatriXX detector for stereotactic volumetric-modulated arc delivery. Twenty-five patients CT images and RT structures from different sites (brain, head & neck, thorax, abdomen, and spine) were taken from CyberKnife Multiplan planning system for this study. All these patients underwent radical stereotactic treatment in CyberKnife.
View Article and Find Full Text PDFAim: To study the influence of segment width on plan quality for volumetric modulated arc based stereotactic body radiotherapy.
Background: The redundancy of modulation for regularly shaped small volume tumors results in creation of many small segments and an increase of monitor units, with a consequent prolongation of treatment and uncertainty in treatment delivery.
Materials And Methods: Six cases each in lung, abdomen and liver were taken for the study.
J Contemp Brachytherapy
June 2013
Purpose: Malignant obstructive jaundice (MOJ) is relieved by stenting via endoscopic retrograde cholangiopancreatography (ERCP) or percutaneous transhepatic cholangiography and biliary drainage (PTCD). Stent occlusion rates of 30-45% have been reported in literature due to tumor ingrowth or overgrowth. We prospectively evaluated the feasibility and the role of intraluminal brachytherapy (ILBT) in preventing stent blockage in patients with MOJ after PTCD and stenting.
View Article and Find Full Text PDFHomogeneity Index (HI) is an objective tool to analyz the uniformity of dose distribution in the target volume. Various formulae have been described in literature for its calculation but there is paucity of data regarding the ideal formula and the factors affecting this index. This study was undertaken to analyze HI in our patients using various formulae and to find out the co-relation between HI and prescribed dose, target volume and target location.
View Article and Find Full Text PDF