Severe vascular complications associated with pacemaker implantation are rare. Typically, they are overt, and require immediate resolution. We present 2 patients with insidious presentation of arteriovenous fistulae due to pacemaker implantation that were recognized early post-implantation.
View Article and Find Full Text PDFCardiac tachyarrhythmias are a major cause of morbidity and mortality. Treatments for these tachyarrhythmias include antiarrhythmic drugs, catheter ablation, surgical ablation, cardiac implantable electronic devices, and cardiac transplantation. Each of these treatment approaches is effective in some patients but there is considerable room for improvement, particularly with respect to the most common of the tachydysrhythmias, atrial fibrillation, and the most dangerous of the tachydysrhythmias, ventricular tachycardia (VT) or ventricular fibrillation.
View Article and Find Full Text PDFA 58-year-old man with previous mitral/aortic mechanical-valve replacement, aortic root repair, and coronary disease developed severe left-ventricular dysfunction following AV-node ablation/single-chamber pacemaker implantation for management of atrial fibrillation. He then underwent an upgrade to cardiac resynchronization therapy with a defibrillator. To manage his heart failure better, angiotensin-receptor blocker therapy was changed to sacubitril/valsartan, after which symptomatic palpitations with T-wave oversensing occurred.
View Article and Find Full Text PDFBackground: Effective communication between the consultants and physicians form an integral foundation of effective and expert patient care. A broad review of the literature has not been undertaken to determine the components of a consultant's letter of most value to the referring physician. We aimed to identify the components of a consultant's letter preferred by referring physicians.
View Article and Find Full Text PDFLeft atrial appendage occlusion devices are an alternative to oral anticoagulation in patients with nonvalvular atrial fibrillation who are at risk of ischemic stroke. Thromboprophylaxis after implantation is recommended, but the optimal regimen is unknown. We report a clinicopathologic case in which thrombus adherent to an incompletely endothelialized WATCHMAN device (Boston Scientific, Marlborough, MA) resulted in multiple thromboembolic events, contributing to a fatal outcome.
View Article and Find Full Text PDFSudden death accounts for 300,000-400,000 deaths annually in the United States. Most sudden deaths are cardiac, and most sudden cardiac deaths are related to arrhythmias secondary to structural heart disease or primary electrical abnormalities of the heart. The most common structural disease leading to sudden death is ischemic heart disease.
View Article and Find Full Text PDF