A retrospective study of 24 neonates to evaluate the feasibility and efficacy of high frequency oscillatory ventilation (HFOV) and inhaled nitric oxide (iNO) for transferring critically ill neonates to tertiary neonatal intensive care, who were transported by road ambulance was done. Efficacy was measured by clinical improvement, patient safety was assessed by comparing cardiorespiratory indicators before and after transport, and adverse events during transport. Significant oxygenation improvement was observed in neonates transported with HFOV ± iNO compared to earlier ventilator settings.
View Article and Find Full Text PDFSimulation based training (SBT) plays a pivotal role in quality improvement and patient safety. Simulation is not only for training health care professionals but also an excellent tool for systems and facility changes which will potentially improve patient safety and ultimately outcomes. SBT is already established both as a training modality, and as a quality improvement tool in high income countries.
View Article and Find Full Text PDFCow's milk protein allergy (CMPA) is the most common food allergy in infants. A previously healthy neonate fed with infant formula presented diarrhoea, vomiting and respiratory distress with cyanosis. Investigations showed thrombocytosis and leucocytosis with lymphocyte predominance.
View Article and Find Full Text PDFThe disaster management cycle is an accepted model that encompasses preparation for and recovery from large-scale disasters. Over the past decade, India's Pediatric Simulation Training and Research Society has developed a national-scale simulation delivery platform, termed the Simulathon , with a period prevalence methodology that integrates with core aspects of this model. As an exemplar of the effectiveness of this approach, we describe the development, implementation, and outcomes of the 2020 Simulathon, conducted from April 20 to May 20 in response to the nascent COVID-19 pandemic disaster.
View Article and Find Full Text PDFAn 8-day-old neonate was presented with severe respiratory distress and diagnosed as primary pulmonary hypertension of the newborn on functional echocardiogram. Evaluation showed bounding pulse, enlarged umbilical cord, and bruit over the periumbilical region. Transthoracic echocardiography and CT angiogram showed a large fistulous communication between the umbilical vein and artery suggestive of congenital umbilical arteriovenous malformation leading to high-output cardiac failure and pulmonary artery hypertension.
View Article and Find Full Text PDF