Publications by authors named "Vijay Vedula"

Background And Objective: Blood flow assessment is an emerging technique that allows for assessment of hemodynamics in the heart and blood vessels. Recent advances in cardiovascular imaging technologies have made it possible for this technique to be more accessible to clinicians and researchers. Blood flow assessment typically refers to two techniques: measurement-based flow visualization using echocardiography or four-dimensional flow magnetic resonance imaging (4D flow MRI), and computer-based flow simulation based on computational fluid dynamics modeling.

View Article and Find Full Text PDF

In numerical simulations of cardiac mechanics, coupling the heart to a model of the circulatory system is essential for capturing physiological cardiac behavior. A popular and efficient technique is to use an electrical circuit analogy, known as a lumped parameter network or zero-dimensional (0D) fluid model, to represent blood flow throughout the cardiovascular system. Due to the strong interaction between the heart and the blood circulation, developing accurate and efficient coupling methods remains an active area of research.

View Article and Find Full Text PDF
Article Synopsis
  • * Researchers analyzed data from 34 patients who underwent septal myectomy, comparing those with significant preoperative MR to those without, revealing worse heart failure symptoms in the former group.
  • * The findings indicate that chordal cutting during septal myectomy may reduce MR severity by improving the tenting area, suggesting it could be an effective treatment for patients with SAM and significant MR.
View Article and Find Full Text PDF

Venous thromboembolism (VTE) is a massive clinical challenge, annually affecting millions of patients globally. VTE is a particularly consequential pathology, as incidence is correlated with extremely common risk factors, and a large cohort of patients experience recurrent VTE after initial intervention. Altered hemodynamics, hypercoagulability, and damaged vascular tissue cause deep-vein thrombosis and pulmonary embolism, the two permutations of VTE.

View Article and Find Full Text PDF

Currently available heart valve prostheses have no growth potential, requiring children with heart valve diseases to endure multiple valve replacement surgeries with compounding risks. This study demonstrates the in vitro proof of concept of a biostable polymeric trileaflet valved conduit designed for surgical implantation and subsequent expansion via transcatheter balloon dilation to accommodate the growth of pediatric patients and delay or avoid repeated open-heart surgeries. The valved conduit is formed via dip molding using a polydimethylsiloxane-based polyurethane, a biocompatible material shown here to be capable of permanent stretching under mechanical loading.

View Article and Find Full Text PDF
Article Synopsis
  • This study investigates if left ventricular remodeling can occur after septal myectomy in patients with obstructive hypertrophic cardiomyopathy, utilizing gated cardiac CT scans for assessment.
  • A review of fifty patients revealed that post-surgery, there were significant decreases in mitral valve regurgitation, ventricular septal thickness, and left ventricular outflow tract pressure gradient, with zero in-hospital mortality.
  • Results indicated that septal myectomy not only reduced the septal band volume but also led to remodeling across the entire left ventricle, with wall thickness decreasing in most myocardial segments.
View Article and Find Full Text PDF

Wall shear stress (WSS) contributes to the mechanotransduction underlying microvascular development and regeneration. Using computational fluid dynamics, we elucidated the interplay between WSS and vascular remodelling in a zebrafish model of tail amputation and regeneration. The transgenic (; ) zebrafish line was used to track the three-dimensional fluorescently labelled vascular endothelium for post-image segmentation and reconstruction of the fluid domain.

View Article and Find Full Text PDF

Purpose: To use computational methods to explore geometric, mechanical, and fluidic biomarkers that could correlate with mouse lifespan in the Fbln4 mouse. Mouse lifespan was used as a surrogate for risk of a severe cardiovascular event in cases of ascending thoracic aortic aneurysm.

Methods: Image-based, mouse-specific fluid-structure-interaction models were developed for Fbln4 mice (n = 10) at ages two and six months.

View Article and Find Full Text PDF

Tissue degradation plays a crucial role in vascular diseases such as atherosclerosis and aneurysms. Computational modeling of vascular hemodynamics incorporating both arterial wall mechanics and tissue degradation has been a challenging task. In this study, we propose a novel finite element method-based approach to model the microscopic degradation of arterial walls and its interaction with blood flow.

View Article and Find Full Text PDF

Tissue degradation plays a crucial role in the formation and rupture of aneurysms. Using numerical computer simulations, we study the combined effects of blood flow and tissue degradation on intra-aneurysm hemodynamics. Our computational analysis reveals that the degradation-induced changes of the time-averaged wall shear stress (TAWSS) and oscillatory shear index (OSI) within the aneurysm dome are inversely correlated.

View Article and Find Full Text PDF

Background: Computed tomography-based evaluation of aortic stenosis (AS) by calcium scoring does not consider interleaflet differences in leaflet characteristics. Here, we sought to examine the functional implications of these differences.

Methods: We retrospectively reviewed the computed tomography angiograms of 200 male patients with degenerative calcific AS undergoing transcatheter aortic valve replacement and 20 male patients with normal aortic valves.

View Article and Find Full Text PDF

A cardiovascular stent design optimization method is proposed with application to a pediatric balloon-expandable prosthetic heart valve. The prosthetic valved conduit may be expanded to a larger permanent diameter via subsequent transcatheter balloon dilation procedures. While multiple expandable prosthetic heart valves are currently at different stages of development, this work is focused on one particular design in which a stent is situated inside of an expandable polymeric valved conduit.

View Article and Find Full Text PDF

Credible computational fluid dynamic (CFD) simulations of aortic dissection are challenging, because the defining parallel flow channels-the true and the false lumen-are separated from each other by a more or less mobile dissection membrane, which is made up of a delaminated portion of the elastic aortic wall. We present a comprehensive numerical framework for CFD simulations of aortic dissection, which captures the complex interplay between physiologic deformation, flow, pressures, and time-averaged wall shear stress (TAWSS) in a patient-specific model. Our numerical model includes (1) two-way fluid-structure interaction (FSI) to describe the dynamic deformation of the vessel wall and dissection flap; (2) prestress and (3) external tissue support of the structural domain to avoid unphysiologic dilation of the aortic wall and stretching of the dissection flap; (4) tethering of the aorta by intercostal and lumbar arteries to restrict translatory motion of the aorta; and a (5) independently defined elastic modulus for the dissection flap and the outer vessel wall to account for their different material properties.

View Article and Find Full Text PDF

Biomechanical forces and endothelial-to-mesenchymal transition (EndoMT) are known to mediate valvulogenesis. However, the relative contributions of myocardial contractile and hemodynamic shear forces remain poorly understood. We integrated 4-D light-sheet imaging of transgenic zebrafish models with moving-domain computational fluid dynamics to determine effects of changes in contractile forces and fluid wall shear stress (WSS) on ventriculobulbar (VB) valve development.

View Article and Find Full Text PDF

While virtual reality (VR) has potential in enhancing cardiovascular diagnosis and treatment, prerequisite labor-intensive image segmentation remains an obstacle for seamlessly simulating 4-dimensional (4-D, 3-D + time) imaging data in an immersive, physiological VR environment. We applied deformable image registration (DIR) in conjunction with 3-D reconstruction and VR implementation to recapitulate developmental cardiac contractile function from light-sheet fluorescence microscopy (LSFM). This method addressed inconsistencies that would arise from independent segmentations of time-dependent data, thereby enabling the creation of a VR environment that fluently simulates cardiac morphological changes.

View Article and Find Full Text PDF

Hemodynamic shear force has been implicated as modulating Notch signaling-mediated cardiac trabeculation. Whether the spatiotemporal variations in wall shear stress (WSS) coordinate the initiation of trabeculation to influence ventricular contractile function remains unknown. Using light-sheet fluorescent microscopy, we reconstructed the 4D moving domain and applied computational fluid dynamics to quantify 4D WSS along the trabecular ridges and in the groves.

View Article and Find Full Text PDF

Blood flow and mechanical forces in the ventricle are implicated in cardiac development and trabeculation. However, the mechanisms of mechanotransduction remain elusive. This is due in part to the challenges associated with accurately quantifying mechanical forces in the developing heart.

View Article and Find Full Text PDF

A methodology for the simulation of heart function that combines an MRI-based model of cardiac electromechanics (CE) with a Navier-Stokes-based hemodynamics model is presented. The CE model consists of two coupled components that simulate the electrical and the mechanical functions of the heart. Accurate representations of ventricular geometry and fiber orientations are constructed from the structural magnetic resonance and the diffusion tensor MR images, respectively.

View Article and Find Full Text PDF

In the present study, we investigate the hemodynamics inside left atrium (LA) and understand its impact on the development of ventricular flow patterns. We construct the heart model using dynamic-computed tomographic images and perform simulations using an immersed boundary method based flow solver. We show that the atrial hemodynamics is characterized by a circulatory flow generated by the left pulmonary veins (LPVs) and a direct stream from the right pulmonary veins (RPVs).

View Article and Find Full Text PDF

A computational study of the flow-structure interaction of a bileaflet mechanical heart valve in the mitral position is presented. Flow in a simple model of the left ventricle is simulated using an immersed boundary method, and the dynamics of the valve leaflets are solved in a fully-coupled manner with the flow. Simulations are conducted for two distinct valve orientations and multiple valve hinge locations, and the performance of the valve is compared in terms of metrics associated with leaflet motion, mitral regurgitation, and mechanical energy losses through the valve.

View Article and Find Full Text PDF

A multiphysics simulation approach is developed for predicting cardiac flows as well as for conducting virtual echocardiography (ECHO) and phonocardiography (PC) of those flows. Intraventricular blood flow in pathological heart conditions is simulated by solving the three-dimensional incompressible Navier-Stokes equations with an immersed boundary method, and using this computational hemodynamic data, echocardiographic and phonocardiographic signals are synthesized by separate simulations that model the physics of ultrasound wave scattering and flow-induced sound, respectively. For virtual ECHO, a Doppler ultrasound image is reproduced through Lagrangian particle tracking of blood cell particles and application of sound wave scattering theory.

View Article and Find Full Text PDF