Publications by authors named "Vijay Swarup"

Background: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF).

Objectives: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden.

Methods: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days).

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness and safety of three techniques to close remaining leaks after incomplete left atrial appendage (LAA) closure in 160 patients, focusing on persistent leaks that can lead to blood clots.
  • Results showed that all patients achieved successful closure immediately after treatment, with high rates of effectiveness maintained after one year, particularly with the atrial septal occluder and vascular plug methods.
  • The study concludes that these three closure techniques are safe and effective for addressing peridevice leaks, with minimal complications reported.
View Article and Find Full Text PDF

Rotating spiral waves are self-organized features in spatially extended excitable media and may play an important role in cardiac arrhythmias including atrial fibrillation (AF). In homogeneous media, spiral wave dynamics are perpetuated through spiral wave breakup, leading to the continuous birth and death of spiral waves, but have a finite probability of termination. In non-homogeneous media, however, heterogeneities can act as anchoring sources that result in sustained spiral wave activity.

View Article and Find Full Text PDF

Background: The Vein of Marshall Ethanol for Untreated Persistent AF (VENUS) trial demonstrated that adding vein of Marshall (VOM) ethanol infusion to catheter ablation (CA) improves ablation outcomes in persistent atrial fibrillation (AF). There was significant heterogeneity in the impact of VOM ethanol infusion on rhythm control.

Objective: The purpose of this study was to assess the association between outcomes and (1) achievement of bidirectional perimitral conduction block and (2) procedural volume.

View Article and Find Full Text PDF

Importance: Catheter ablation of persistent atrial fibrillation (AF) has limited success. Procedural strategies beyond pulmonary vein isolation have failed to consistently improve results. The vein of Marshall contains innervation and AF triggers that can be ablated by retrograde ethanol infusion.

View Article and Find Full Text PDF

Objectives: The present study describes the use of octreotide (OCT) in patients with atrial fibrillation (AF) receiving oral anticoagulation (OAC) who have gastrointestinal (GI) bleeding related to arteriovenous malformations (AVMs), as well as its effect on OAC tolerance and subsequent rebleeding.

Background: AVMs cause significant GI bleeding, especially in patients with AF who are receiving OAC for stroke prevention. OCT has been shown to minimize recurrent GI bleeds related to AVMs.

View Article and Find Full Text PDF

Background: In a randomized trial, baroreflex activation therapy (BAT) improved exercise capacity, quality of life and NT-proBNP in patients with heart failure with reduced ejection fraction (HFrEF). In view of different mechanisms underlying HFrEF, we performed a post-hoc subgroup analysis of efficacy and safety of BAT in patients with and without coronary artery disease (CAD).

Methods And Results: Patients with left ventricular ejection fraction <35% and NYHA Class III were randomized 1:1 to guideline-directed medical and device therapy alone or plus BAT.

View Article and Find Full Text PDF

Background: Esophageal thermal injury is a feared complication of radiofrequency ablation for atrial fibrillation (AF). Rise in luminal esophageal temperature (LET) limits the ability to deliver radiofrequency energy on the posterior wall of the left atrium.

Objective: The purpose of this study was to evaluate the feasibility, safety, and efficacy of a mechanical esophageal deviation (ED) tool during AF ablation.

View Article and Find Full Text PDF

Background: Silent cerebral lesions (SCLs) are a potential complication of left atrial radiofrequency ablation (RFA) procedures for paroxysmal atrial fibrillation (PAF). We aimed to compare the incidence of SCLs in patients treated with irrigated RFA multielectrode catheters (nMARQ Catheter group) and irrigated focal RFA catheters (NAVISTAR THERMOCOOL Catheter; TC group) after PAF ablation from subpopulation neurological assessment (SNA) cohorts of the REVOLUTION and reMARQable studies.

Methods: Data from SNA cohorts in the prospective, nonrandomized REVOLUTION study (March 2011-September 2013) and the prospective, randomized, controlled reMARQable study (October 2013-November 2015) were included.

View Article and Find Full Text PDF

Introduction: The role of atrial fibrillation (AF) substrates is unclear in patients with paroxysmal AF (PAF) that recurs after pulmonary vein isolation (PVI). We hypothesized that patients with recurrent post-ablation (redo) PAF despite PVI have electrical substrates marked by rotors and focal sources, and structural substrates that resemble persistent AF more than patients with (de novo) PAF at first ablation.

Methods: In 175 patients at 11 centers, we compared AF substrates in both atria using 64 pole-basket catheters and phase mapping, and indices of anatomical remodeling between patients with de novo or redo PAF and first ablation for persistent AF.

View Article and Find Full Text PDF

Background: Pocket hematoma is a recognized complication after placement of cardiac implantable electronic devices and is associated with increased device infection, length of hospitalization, and morbidity especially with uninterrupted antiplatelet agents and anticoagulants. We assessed the use of a post-surgical vest to decrease the incidence of pocket hematoma in patients undergoing device implantation with uninterrupted antiplatelet and anticoagulants.

Methods: In this observational study, a vest was used by 20 consecutive patients who were compared to 20 age-, gender-, procedure-matched patients who received standard care.

View Article and Find Full Text PDF

The purpose of this publication is to describe the intraoperative experience along with long-term safety and efficacy of the second-generation baroreflex activation therapy (BAT) system in patients with heart failure (HF) and reduced ejection fraction HF (HFrEF). In a randomized trial of New York Heart Association Class III HFrEF, 140 patients were assigned 1:1 to receive BAT plus medical therapy or medical therapy alone. Procedural information along with safety and efficacy data were collected and analyzed over 12 months.

View Article and Find Full Text PDF

Background: There have been an increasing number of atrial fibrillation (AF) patients with Watchman left atrial appendage occlusion (LAAO) device, requiring catheter ablation (CA) for maintenance of normal sinus rhythm. In this study, we describe our experience with the feasibility and safety of CA in patients with a preexisting Watchman LAAO device.

Methods: This was a retrospective multicenter AF registry of 60 patients with Watchman LAAO device who underwent CA for AF.

View Article and Find Full Text PDF

Background: In the stroke prevention trials of left atrial appendage closure with the Watchman device (Boston Scientific), a postimplantation antithrombotic regimen of 6 weeks of warfarin was used.

Objective: Given the clinical complexity of warfarin use, the purpose of this study was to study the relative feasibility and safety of using non-warfarin oral anticoagulants (NOACs) instead of warfarin during the peri- and initial postimplantation periods after Watchman implantation.

Methods: This was a retrospective multicenter study of consecutive patients undergoing Watchman implantation and receiving peri- and postprocedural NOACs or warfarin.

View Article and Find Full Text PDF

Aims: Focal Impulse and Rotor Modulation (FIRM) uses 64-electrode basket catheters to identify atrial fibrillation (AF)-sustaining sites for ablation, with promising results in many studies. Accordingly, new basket designs are being tested by several groups. We set out to determine the procedural safety of adding basket mapping and map-guided ablation to conventional pulmonary vein isolation (PVI).

View Article and Find Full Text PDF

Background: A dry epicardial access (EA) is increasingly used for advanced cardiovascular procedures. Conventionally used large bore needles (Tuohy or Pajunk needle; LBN) have been associated with low but definite incidence of major complications with EA. Use of micropuncture needle (MPN) may decrease the risk of complications.

View Article and Find Full Text PDF

Aims: Increased sympathetic and decreased parasympathetic activity contribute to heart failure (HF) symptoms and disease progression. Carotid baroreceptor stimulation (baroreflex activation therapy, BAT) results in centrally mediated reduction of sympathetic and increase in parasympathetic activity. Because patients treated with cardiac resynchronization therapy (CRT) may have less sympathetic/parasympathetic imbalance, we hypothesized that there would be differences in the response to BAT in patients with CRT vs.

View Article and Find Full Text PDF

Objectives: The objective of this clinical trial was to assess the safety and efficacy of carotid BAT in advanced HF.

Background: Increased sympathetic and decreased parasympathetic activity contribute to heart failure (HF) symptoms and disease progression. Baroreflex activation therapy (BAT) results in centrally mediated reduction of sympathetic outflow and increased parasympathetic activity.

View Article and Find Full Text PDF

Background: Watchman and Lariat left atrial appendage (LAA) occlusion devices are associated with LAA leaks postdeployment.

Objective: The purpose of this study was to compare the incidence, characteristics, and clinical significance of these leaks.

Methods: We performed a multicenter prospective observational study of all patients who underwent LAA closure.

View Article and Find Full Text PDF

Despite significant advances in our understanding of atrial fibrillation (AF) mechanisms in the last 15 years, ablation outcomes remain suboptimal. A potential reason is that many ablation techniques focus on anatomic, rather than patient-specific functional targets for ablation. Panoramic contact mapping, incorporating phase analysis, repolarization and conduction dynamics, and oscillations in AF rate, overcomes many prior difficulties with mapping AF.

View Article and Find Full Text PDF

Importance: While effective in preventing stroke in patients with atrial fibrillation (AF), warfarin is limited by a narrow therapeutic profile, a need for lifelong coagulation monitoring, and multiple drug and diet interactions.

Objective: To determine whether a local strategy of mechanical left atrial appendage (LAA) closure was noninferior to warfarin.

Design, Setting, And Participants: PROTECT AF was a multicenter, randomized (2:1), unblinded, Bayesian-designed study conducted at 59 hospitals of 707 patients with nonvalvular AF and at least 1 additional stroke risk factor (CHADS2 score ≥1).

View Article and Find Full Text PDF

Introduction: Several groups report electrical rotors or focal sources that sustain atrial fibrillation (AF) after it has been triggered. However, it is difficult to separate stable from unstable activity in prior studies that examined only seconds of AF. We applied phase-based focal impulse and rotor mapping (FIRM) to study the dynamics of rotors/sources in human AF over prolonged periods of time.

View Article and Find Full Text PDF

Introduction: The success of pulmonary vein isolation (PVI) for atrial fibrillation (AF) may be improved if stable AF sources identified by Focal Impulse and Rotor Mapping (FIRM) are also eliminated. The long-term results of this approach are unclear outside the centers where FIRM was developed; thus, we assessed outcomes of FIRM-guided AF ablation in the first cases at 10 experienced centers.

Methods: We prospectively enrolled n = 78 consecutive patients (61 ± 10 years) undergoing FIRM guided ablation for persistent (n = 48), longstanding persistent (n = 7), or paroxysmal (n = 23) AF.

View Article and Find Full Text PDF

Background: Data on relative safety, efficacy, and role of different percutaneous left ventricular assist devices for hemodynamic support during the ventricular tachycardia (VT) ablation procedure are limited.

Methods And Results: We performed a multicenter, observational study from a prospective registry including all consecutive patients (N=66) undergoing VT ablation with a percutaneous left ventricular assist devices in 6 centers in the United States. Patients with intra-aortic balloon pump (IABP group; N=22) were compared with patients with either an Impella or a TandemHeart device (non-IABP group; N=44).

View Article and Find Full Text PDF