Publications by authors named "Vignaud A"

Ultra-high field MRI with parallel transmission (pTx) provides a powerful neuroimaging tool with potential application in paediatrics. The use of pTx, however, necessitates a dedicated local specific absorption rate (SAR) management strategy, able to predict and monitor the peak local SAR (pSAR). In this work, we address the pSARassessment for an in-house built 7 Tesla 16Tx32Rx pediatric head coil, using the concept of Virtual Observation Points (VOPs) for SAR estimation.

View Article and Find Full Text PDF

Intramuscular injection of botulinum neurotoxin type A (BoNT-A) is commonly used to improve or maintain the joint range of motion in young children with spasticity. However, the effectiveness of BoNT-A treatment is variable and movement limitations are recurrent. Here we show long-term effects of a single, bilateral abobotulinumtoxinA (aboBoNT-A) injection in the gastrocnemius medialis and soleus muscles of wild-type and spastic (B6.

View Article and Find Full Text PDF

Background: Iron accumulates in the brain during aging and is the focus of intensive research as an abnormal load, particularly in Deep Gray Matter (DGM), is related to neurodegeneration. Magnetic Resonance Imaging (MRI) metrics such as Quantitative Susceptibility Mapping (QSM) and apparent transverse relaxation rate can be used to follow up iron . While the influence of age and sex on iron levels has already been reported, a careful consideration of neuronal risk factors, as well as for an enhanced sensitivity, is needed to define the normal evolution.

View Article and Find Full Text PDF

The understanding of the human brain is one of the main scientific challenges of the twenty-first century. In the early 2000s, the French Atomic Energy Commission launched a program to conceive and build a human magnetic resonance imaging scanner operating at 11.7 T.

View Article and Find Full Text PDF

The quest for higher spatial and/or temporal resolution in functional MRI (fMRI) while preserving a sufficient temporal signal-to-noise ratio (tSNR) has generated a tremendous amount of methodological contributions in the last decade ranging from Cartesian vs. non-Cartesian readouts, 2D vs. 3D acquisition strategies, parallel imaging and/or compressed sensing (CS) accelerations and simultaneous multi-slice acquisitions to cite a few.

View Article and Find Full Text PDF

Much of human culture's advanced technology owes its existence to the ability to mentally manipulate quantities. Neuroscience has described the brain regions overall recruited by numerical tasks and the neuronal codes representing individual quantities during perceptual tasks. Nevertheless, it remains unknown how quantity representations are combined or transformed during mental computations and how specific quantities are coded in the brain when generated as the result of internal computations rather than evoked by a stimulus.

View Article and Find Full Text PDF

Objective: To assess the possible influence of third-order shim coils on the behavior of the gradient field and in gradient-magnet interactions at 7 T and above.

Materials And Methods: Gradient impulse response function measurements were performed at 5 sites spanning field strengths from 7 to 11.7 T, all of them sharing the same exact whole-body gradient coil design.

View Article and Find Full Text PDF

Purpose: Static and dynamic field imperfections are detrimental to functional MRI (fMRI) applications, especially at ultra-high magnetic fields (UHF). In this work, a field camera is used to assess the benefits of retrospectively correcting field perturbations on Blood Oxygen Level Dependent (BOLD) sensitivity in non-Cartesian three-dimensional (3D)-SPARKLING fMRI acquisitions.

Methods: fMRI data were acquired at 1 mm and for a 2.

View Article and Find Full Text PDF

Purpose: MP2RAGE parameter optimization is redefined to allow more time-efficient MR acquisitions, whereas the T -based synthetic imaging framework is used to obtain on-demand T -weighted contrasts. Our aim was to validate this concept on healthy volunteers and patients with multiple sclerosis, using plug-and-play parallel-transmission brain imaging at 7 T.

Methods: A "time-efficient" MP2RAGE sequence was designed with optimized parameters including TI and TR set as small as possible.

View Article and Find Full Text PDF

Purpose: Testing an RF coil prototype on subjects involves laborious verifications to ensure its safety. In particular, it requires preliminary electromagnetic simulations and their validations on phantoms to accurately predict the specific absorption rate (SAR). For coil design validation with a simpler safety procedure, the restricted SAR (rS) mode is proposed, enabling representative first experiments in vivo.

View Article and Find Full Text PDF

Purpose: We propose a comprehensive workflow to design and build fully customized dense receive arrays for MRI, providing prediction of SNR and g-factor. Combined with additive manufacturing, this method allows an efficient implementation for any arbitrary loop configuration. To demonstrate the methodology, an innovative two-layer, 32-channel receive array is proposed.

View Article and Find Full Text PDF

Purpose: Patient-induced inhomogeneities in the static magnetic field cause distortions and blurring (off-resonance artifacts) during acquisitions with long readouts such as in SWI. Conventional versatile correction methods based on extended Fourier models are too slow for clinical practice in computationally demanding cases such as 3D high-resolution non-Cartesian multi-coil acquisitions.

Theory: Most reconstruction methods can be accelerated when performing off-resonance correction by reducing the number of iterations, compressed coils, and correction components.

View Article and Find Full Text PDF

Purpose: Non-Cartesian MRI with long arbitrary readout directions are susceptible to off-resonance artifacts due to patient induced inhomogeneities. This results in degraded image quality with strong signal losses and blurring. Current solutions to address this issue involve correcting the off-resonance artifacts during image reconstruction or reducing inhomogeneities through improved shimming.

View Article and Find Full Text PDF

Purpose: To optimize the homogeneity of the presaturation module in a Chemical Exchange Saturation Transfer (CEST) acquisition at 7 T using parallel transmission (pTx).

Theory And Methods: An optimized pTx-CEST presaturation scheme based on precomputed universal pulses was designed. The optimization was performed by minimizing the L2-norm between the effective and a given target while imposing energy constraints under virtual observation points (VOPs) supervision.

View Article and Find Full Text PDF

Increased static field inhomogeneities are a burden for human brain MRI at Ultra-High-Field. In particular they cause enhanced Echo-Planar image distortions and signal losses due to magnetic susceptibility gradients at air-tissue interfaces in the subject's head. In the past decade, Multi-Coil Arrays (MCA) have been proposed to shim the field in the brain better than the 2nd or 3rd order Spherical Harmonic (SH) coils usually offered by MRI manufacturers.

View Article and Find Full Text PDF

Purpose: The SNR at the center of a spherical phantom of known electrical properties was measured in quasi-identical experimental conditions as a function of magnetic field strength between 3 T and 11.7 T.

Methods: The SNR was measured at the center of a spherical water saline phantom with a gradient-recalled echo sequence.

View Article and Find Full Text PDF

Purpose: Patient-induced inhomogeneities in the magnetic field cause distortions and blurring during acquisitions with long readouts such as in susceptibility-weighted imaging (SWI). Most correction methods require collecting an additional field map to remove these artifacts.

Theory: The static field map can be approximated with an acceptable error directly from a single echo acquisition in SWI.

View Article and Find Full Text PDF

Purpose: The use of dielectric pads to redistribute the radiofrequency fields is currently a popular solution for 7 T MRI practical applications, especially in brain imaging. In this work, we tackle several downsides of the previous generation of dielectric pads. This new silicon carbide recipe makes them MR invisible and greatly extends the performance lifespan.

View Article and Find Full Text PDF

The Spreading Projection Algorithm for Rapid K-space sampLING, or SPARKLING, is an optimization-driven method that has been recently introduced for accelerated 2D MRI using compressed sensing. It has then been extended to address 3D imaging using either stacks of 2D sampling patterns or a local 3D strategy that optimizes a single sampling trajectory at a time. 2D SPARKLING actually performs variable density sampling (VDS) along a prescribed target density while maximizing sampling efficiency and meeting the gradient-based hardware constraints.

View Article and Find Full Text PDF

Spasticity is the most common neurological disorder associated with increased muscle contraction causing impaired movement and gait. The aim of this study was to characterize the physical performance, skeletal muscle function, and phenotype of mice with a hereditary spastic mutation (B6.Cg-Glrb/J).

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the unclear mechanisms behind neuronal changes in Alzheimer's disease, highlighting metabolic energy deficits and sodium imbalance as important factors.
  • Using advanced 7 Tesla MR imaging, researchers measured increased sodium concentration in the brains of Alzheimer's patients, distinguishing them from healthy controls and linking it to cognitive decline and tau protein levels.
  • The findings suggest that sodium concentration could be a valuable, non-invasive marker for monitoring Alzheimer's progression and that targeting cellular metabolism might help slow cognitive decline in future treatments.
View Article and Find Full Text PDF

For functional MRI with a multi-channel receiver RF coil, images are often reconstructed channel by channel, resulting into multiple images per time frame. The final image to analyze usually is the result of the covariance Sum-of-Squares (covSoS) combination across these channels. Although this reconstruction is quasi-optimal in SNR, it is not necessarily the case in terms of temporal SNR (tSNR) of the time series, which is yet a more relevant metric for fMRI data quality.

View Article and Find Full Text PDF

Purpose: An MR thermometry (MRT) method with motion and field fluctuation compensation is proposed to measure non-invasively sub-degree brain temperature variations occurring through radiofrequency (RF) power deposition during MR exams.

Methods: MRT at 7T with a multi-slice echo planar imaging (EPI) sequence and concurrent field monitoring was first tested in vitro to assess accuracy in the presence of external field perturbations, an optical probe being used for ground truth. In vivo, this strategy was complemented by a motion compensation scheme based on a dictionary pre-scan, as reported in some previous work, and was adapted to the human brain.

View Article and Find Full Text PDF

Clinically used botulinum neurotoxins (BoNTs) are natural products of Clostridium botulinum. A novel, recombinant BoNT type A1 (rBoNT/A1; IPN10260) has been synthesized using the native amino acid sequence expressed in Escherichia coli and has previously been characterized in vitro and ex vivo. Here, we aimed to characterize rBoNT/A1 in vivo and evaluate its effects on skeletal muscle.

View Article and Find Full Text PDF
Article Synopsis
  • The study explores a new design for a birdcage coil for 7 Tesla brain imaging, featuring an open top for enhanced patient comfort and interaction during scans.
  • The coil utilizes a nonperiodic, optimized structure and is tested using simulations and experimental methods to ensure efficiency and homogeneity.
  • Results indicate this new coil design maintains performance levels similar to traditional coils while improving patient experience during functional MRI studies.
View Article and Find Full Text PDF