Introduction: This study aimed to evaluate the mechanical properties of Reciproc, Reciproc Blue, One RECI, and R-Motion, specifically focusing on their flexibility and buckling resistance; and to assess their torsional fatigue behavior under two different reciprocation angles (150°/30° or 70°/30°).
Methods: A total of 160 instruments (40 per brand) were tested. Flexion and buckling tests were conducted using a Universal testing machine (DL 200MF) was used.
Int J Equity Health
December 2024
Background: Most transgender people face different conditions of health vulnerability on a daily basis. In the Brazilian context, no research review has been found on such situations in the light of the theoretical conceptualization of multidimensional vulnerability. This research aimed to identify and analyze components of social and/or programmatic vulnerability that interfere with access to health care for trans people in Brazil.
View Article and Find Full Text PDFIntroduction: This study aimed to compare a new multicolored rotary system with four heat-treated rotary instruments using the multimethod approach.
Methods: Three-hundred instruments of RCS Rainbow, Rotate, RaCe EVO, OneCurve, and ProTaper Ultimate systems were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy, and mechanical performance (cyclic fatigue, torsional resistance, bending and buckling resistance, and cutting ability). Unprepared surfaces after canal preparation of maxillary molars were evaluated using micro-computed tomography.
Aim: To compare the effects of Cervical Access Cavity (CervAC) and Traditional Access Cavity (TradAC) on root canal preparation, root canal filling, and fracture resistance in mandibular incisors.
Methodology: Twenty recently extracted and intact mandibular incisors were initially scanned using a micro-CT device. The specimens were anatomically matched to create two groups (n = 10).
This study assessed the mechanical properties of the Only One File Blue and the Reciproc Blue instruments. A total of 80 new 25 mm reciprocating NiTi instruments (25/.08v) were evaluated for their mechanical performance (n = 40 per group).
View Article and Find Full Text PDFAim: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model.
Methodology: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.
Aim: To assess the influence of a flat-side design on the geometry, metallurgy, mechanical performance and shaping ability of a novel nickel-titanium rotary instrument.
Methodology: Sixty-five new 25-mm flat-side rotary instruments (size 25, taper 0.04) and their nonflat-side prototypes (n = 65) were assessed for major deformations and examined regarding macroscopic and microscopic design, determination of nickel and titanium elements ratio, measurement of phase transformation temperature and evaluation of mechanical performance parameters including time/cycles to fracture, maximum torque, angle of rotation, maximum bending and buckling strengths and cutting ability.
Aim: This study aimed to compare three rotary instruments produced by the EDM process with the heat-treated ProTaper Gold system regarding design, metallurgy, mechanical properties and shaping ability.
Methodology: HyFlex EDM (25/~), Neoniti (25/.06), EDMax (25/.
Objective: This study aimed to compare 3 reciprocating systems regarding design, metallurgy, mechanical properties, and shaping ability.
Materials And Methods: New Reciproc Blue R25, WaveOne Gold Primary, and REX 25 instruments (n=41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin, and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. Results were compared using one-way ANOVA post hoc Tukey and Kruskal-Wallis tests with a significant level set at 5%.
Introduction: The aim of this study was to compare E1-Irrisonic (Helse Ultrasonics, Ocoee, FL) and Irri Black (Helse Ultrasonics), a novel ultrasonic tip with diamondlike carbon treatment, regarding their design, metallurgy, microhardness, bending resistance, and time to fracture under the oscillatory fatigue test.
Methods: A total of 17 E1-Irrisonic and 17 Irri Black new ultrasonic tips were selected. The tip geometry and surface finishing were assessed using scanning electron microscopy.
Objective: The aim of this study was to compare the cyclic fatigue of heat-treated and non-treated instruments.
Materials And Methods: Twenty instruments with and without heat treatment from Bassi Logic were evaluated ( = 10). All instruments were subjected to dynamic cyclic fatigue through continuous rotations inside a stainless-steel tube (1.
The present study aimed to perform two different heat-treatments in an austenitic NiTi ProFile instrument and to compare the mechanical performance of original and heat-treated instruments. Heat treatment of ProFile (tip size 25 and 0.06 taper) instruments were carried out in a furnace in argon atmosphere using a heating rate of 10° C/min.
View Article and Find Full Text PDFThis study aimed to compare three endodontic rotary systems. The new Genius Proflex (25/0.04), Vortex Blue (25/0.
View Article and Find Full Text PDFThe management of colorectal cancer liver metastasis (CRLM) has become complex because of the increasing availability of medical, radiological, and surgical treatment options applied either alone or in combination. However, resection remains the only evidence-based curative therapy. These Brazilian Society of Surgical Oncology surgical standards are intended to guide clinicians in the decision-making process for modern surgical management of CRLM within a multidisciplinary team in an evidence-based framework, focusing on resectable disease.
View Article and Find Full Text PDFThe current study aimed to compare the F1 endodontic instruments from five different heat-treated rotary systems regarding their design, metallurgical properties, and mechanical performance. Five F1 root canal shaping instruments (ProTaper Gold [PTG], Premium Taper Gold, Go-Taper Flex, EdgeTaper Platinum, and Super Files Blue)-plus, a conventional ProTaper Universal (PTU)-which were evaluated regarding their design, nickel/titanium ratio, phase transformation temperatures, microhardness, cyclic fatigue, and torsional and bending strengths. Mood's median test was used for the statistical comparison with a significance set at 5%.
View Article and Find Full Text PDFA root-end filling material is required to fill the root-end cavity without gaps or voids, to prevent root canal reinfection and to provide periapical healing. Thus, this study evaluated the volume of marginal gaps and voids of three root-end filling materials using microcomputed tomography (micro-CT). Thirty maxillary incisors were prepared and filled with gutta-percha and endodontic sealer.
View Article and Find Full Text PDFBackground: We have previously described CxxCpep, a peptide with anti-platelet properties that inhibits peri/epicellular protein disulphide isomerase (pecPDI) by forming a mixed disulfide bond with Cys400 within the pecPDI active site.
Objectives: Here we sought to determine if pecPDI targeted by CxxCpep is relevant to redox mechanisms downstream of the collagen receptor GPVI in platelets.
Methods And Results: Restriction of effects of CxxCpep to the platelet surface was confirmed by LC-MS/MS following cell fractionation.
The aim of the present study was to evaluate the cyclic fatigue, torsional resistance and surface roughness of Reciproc R25 instruments in four different situations, namely as new instruments and as instruments tested after clinical preparation of one, two or three maxillary molars with four root canals. The total time required to perform each root canal preparation was recorded. Cyclic fatigue resistance was determined by the time to fracture using a customized testing device (n = 10 per group).
View Article and Find Full Text PDFObjective: To evaluate cyclic fatigue and torsional resistance of Reciproc Blue R25 (VDW, Munich, Germany), WaveOne Gold Primary (Dentsply Maillefer, Ballaigues, Switzerland), ProDesign R (Easy Equipamentos Odontológicos, Belo Horizonte, Brazil), and X1 Blue File (MK Life, Porto Alegre, Brazil) nickel titanium (NiTi) martensite reciprocating instruments.
Methods: In each group, ten instruments were tested for cyclic fatigue resistance using a stainless-steel artificial canal (curvature angle of 80° and radius of 3 mm) and ten instruments for torsional failure according to ISO 3630-1 standard. The surface of the fractured instruments was examined under scanning electron microscopy (SEM) at ×250 magnification.
Introduction: The aim of the present study was to compare the cyclic fatigue resistance of Reciproc R25 (R25) and Reciproc Blue R25 (R25B) instruments, after simulated clinical use in traditional (TradAC) and ultraconservative (UltraAC) endodontic access cavities.
Methods: Forty mandibular molars were randomly assigned into the following groups, according to the type of access and instrument to be used: TradAC and R25, TradAC and R25B, UltraAC and R25, and UltraAC and R25B. Teeth were accessed accordingly, and the root canals were prepared using "RECIPROC ALL" kinematics.
Introduction: This study aimed to compare the mechanical and metallurgical properties and shaping ability of different rotary systems using a multimethod approach.
Methods: New NeoNiti A1 (Neolix SAS, Châtres-La-Forêt, France), HyFlex EDM One File (Coltène/Whaledent, Altstätten, Switzerland), ProTaper Gold F2 (Dentsply Maillefer, Ballaigues, Switzerland), and ProTaper Universal F2 (Dentsply Maillefer) rotary instruments were tested regarding cyclic fatigue, torsional resistance, design, and morphologic characteristics using scanning electron microscopy, metal alloy characterization using differential scanning calorimetry, and energy-dispersive X-ray spectroscopy. Additionally, their shaping ability on the preparation of 48 canals of maxillary molars was evaluated using micro-computed tomographic technology.
Background: This study evaluated the cytotoxicity, antibacterial and physicochemical properties of a new epoxy resin-based endodontic sealer containing calcium-hydroxide Sealer Plus. AH Plus was used as a reference for comparison.
Material And Methods: Cytotoxicity evaluation was performed according to ISO-10993-5 specifications using MTT assay to check the 3T3 cells viability at 1- to 4-week periods.
J Contemp Dent Pract
December 2019
Aim: The aim of this study was to evaluate the force-release behavior of closed coil nickel-titanium springs of three different commercial brands available on the market, as well those from different batches, tested over multiple distances, according to the number of deactivations.
Materials And Methods: For this analysis, closed coil nickel-titanium springs of the following numbers and brands: eight, 3 mm GAC® springs; eight, 3 mm springs from TP Orthodontics® and eight, 5 mm springs from MORELLI® were standardized at 200 gf force. Two batches of all three brands were tested and compared.
Municipal biowaste is a major environmental issue. Life-cycle assessment is a valuable tool to assess recycling options, and anaerobic digestion and composting have performed adequately. However, reviews indicate several discrepancies between studies.
View Article and Find Full Text PDF