Publications by authors named "Victor Geanta"

The structure, composition and corrosion properties of thin films synthesized using the Pulsed Laser Deposition (PLD) technique starting from a three high entropy alloy (HEA) AlCoCrFeNix produced by vacuum arc remelting (VAR) method were investigated. The depositions were performed at room temperature on Si and mirror-like polished Ti substrates either under residual vacuum (low 10 mbar, films denoted HEA2, HEA6, and HEA10, which were grown from targets with Ni concentration molar ratio, x, equal to 0.4, 1.

View Article and Find Full Text PDF

Titanium and its based alloys are frequently selected for designing biomedical implants and it is thus necessary to study as detailed as possible their corrosion behavior in biological solutions, such as those in the human body environment. In this paper, with the use of molecular orbital calculation, we designed and developed alloys in the Ti-19Mo-xW system (x = 7, 8, 9, and 10 wt%) and investigated the influence of different contents of tungsten on the behavior of Ti-19Mo-xW alloy samples following corrosion in simulated body fluid (SBF). The values of Bo¯ (bond order) and Md¯ (the metal-orbital energy level) were calculated for each alloy and correlations were established between Bo¯ and the content of tungsten.

View Article and Find Full Text PDF

The aim of the paper is to study the Zr addition effect on the mechanical properties and corrosion behavior of a high-entropy alloy from the CoCrFeMoNi system. This alloy was designed to be used for components in the geothermal industry that are exposed to high temperature and corrosion. Two alloys, one Zr-free (named Sample 1) and another one doped with 0.

View Article and Find Full Text PDF

Special materials are required in many applications to fulfill specific medical or industrial necessities. Biodegradable metallic materials present many attractive properties, especially mechanical ones correlated with good biocompatibility with vivant bodies. A biodegradable iron-based material was realized through electric arc-melting and induction furnace homogenization.

View Article and Find Full Text PDF
Article Synopsis
  • * Several new titanium alloys (including TiMoZrTa and TiMoZrTaSi) were created and tested for their microstructure and biological compatibility, showing positive interactions with bone tissues.
  • * After 60 days in rabbits, the implants demonstrated good osseointegration, as indicated by the presence of mesenchymal stem cells differentiating into bone-forming cells, and in vitro tests confirmed the alloys' cytocompatibility.
View Article and Find Full Text PDF

Considering the future trends of biomaterials, current studies are focused on the corrosion resistance and the mechanical properties of new materials that need to be considered in the process of strengthening alloys with additive non-toxic elements. Many kinds of titanium alloys with different biocompatible elements (Mo, Si, Zr, etc.,) have been recently developed for their similar properties with human bone.

View Article and Find Full Text PDF

Several newly obtained titanium alloys were characterized in order to evaluate the biocompatibility and their possible application as implants. For improvement of the performances of the TiMo alloys compared to other alloys, silicon was added, targeting good mechanical and technological properties, avoiding the toxic effects for human body. Titanium is very used in medical applications, due to their extremely low toxicity and good chemical stability in different body fluids.

View Article and Find Full Text PDF

Lightweight complex concentrated alloys (LWCCA), composed of elements with low density, have become a great area of interest due to the high demand in a large number of applications. Previous research on LWCCAs was focused on high entropy multicomponent alloy systems that provide low density and high capability of solid solution formation. Present research introduces two alloy systems (Al-Cu-Si-Zn-Mg and Al-Mn-Zn-Mg-Si) that contain readily available and inexpensive starting materials and have potential for solid solution formation structures.

View Article and Find Full Text PDF

The development of novel Ti-based amorphous or β-phase nanostructured metallic materials could have significant benefits for implant applications, due to potentially improved corrosion properties, and mechanical characteristics (lower Young's modulus, better wear performance, improved fracture toughness) in comparison to the standardized + titanium alloys. Moreover, the devitrification phenomenon, occurring during heating, could contribute to lower input power during additive manufacturing technologies. Ti-based alloy ribbons were obtained by melt-spinning, considering the ultra-fast cooling rates this method can provide.

View Article and Find Full Text PDF

The paper presents the microstructure and corrosion behavior of an AlTiNiCuAgSn new equiatomic multicomponent alloy. The alloy was obtained using the vacuum arc remelting (VAR) technique in MRF-ABJ900 equipment. The microstructural analysis was performed by optical and scanning electron microscopy (SEM microscope, SEM-EDS) and the phase transformations were highlighted by dilatometric analysis and differential thermal analysis (DTA).

View Article and Find Full Text PDF

The β-Ti alloys have attracted the attention of researchers due to their excellent properties and their remarkable biocompatibility. The present study evaluated the mechanical behavior analysis (hardness, compressive strength, and modulus of elasticity) of the Ti-15Mo-W system. For experimental research, we chose the TiMo15 biocompatible alloy as a starting material.

View Article and Find Full Text PDF