Despite the progresses performed in the field of radiotherapy, toxicity to the healthy tissues remains a major limiting factor. The aim of this work was to highlight blood biomarkers whose variations could predict the occurrence of late cutaneous side effects. Two groups of nine patients treated for Merkel Cell Carcinoma (MCC) were established according to the grade of late skin toxicity after adjuvant irradiation for MCC: grade 0, 1 or 2 and grade 3 or 4 of RTOG (Radiation Therapy Oncology Group)/EORTC (European Organization for Research and Treatment of Cancer).
View Article and Find Full Text PDFBackground: Stereotactic irradiation (SBRT) is a standard of care for inoperable stage I lung cancer and brain oligometastases from lung cancer but is controversial for extracranial oligometastases. We assessed outcomes of lung cancer patients with extracranial metastases in oligometastatic, oligorecurrent, oligopersistent and oligoprogressive settings ("oligometastatic spectrum") under strategies using SBRT +/- systemic treatments.
Methods: A retrospective multicentric study of consecutive lung cancer adult patients with 1-5 extracranial metastases treated with SBRT was conducted.
Purpose: Correct tandem implantation for cervix cancer intracavitary brachytherapy may be challenging. We investigated whether suboptimal implantation can be related to patient and disease characteristics and may result in subsequent underutilization of brachytherapy in cervical cancer.
Methods And Materials: Consecutive cervix cancer patients referred for intracavitary brachytherapy after external beam radiation therapy performed in several general hospitals from 2013 to 2017 were included.
Background: Until 50% of patients with renal cancer or melanoma, develop brain metastases during the course of their disease. Stereotactic radiotherapy has become a standard of care for patients with a limited number of brain metastases. Given the radioresistant nature of melanoma and renal cancer, optimization of the fractionation of stereotactic radiotherapy is needed.
View Article and Find Full Text PDFPurpose: The purpose of this study was to analyze the detector responses in non-equilibrium small photon fields.
Methods: Five detectors (PTW 31014 ionization chamber, PTW 60016, PTW 60017 and Sun Nuclear EDGE diodes and PTW 60003 diamond detector) and one passive dosimeter (Harshaw micro-LiF) as well as a 1000MU/min CyberKnife were modeled with the PENELOPE Monte Carlo code. Field factors, [Formula: see text] were calculated and perturbations due to volume averaging effect, active material effect and coating effect were quantified for the five detectors and passive dosimeter.