Medicina (Kaunas)
October 2024
The Coronal Plane Alignment of the Knee (CPAK) classification is a pragmatic distribution of nine phenotypes for coronal knee alignment that can be used on healthy and arthritic knees. Our study aimed to describe the CPAK distributions in a Spanish southeast osteoarthritic population and compare them to other populations' published alignment distributions. Full-leg standing X-rays of the lower limb from 528 cases originating from the so-called Vega Alta del Segura (southeast of the Iberian Peninsula) were retrospectively analysed.
View Article and Find Full Text PDFThe Cobb angle is critical in assessing adolescent idiopathic scoliosis (AIS) patients. This study aimed to evaluate the error in selecting the upper- and lower-end vertebrae on AIS digital X-rays by experienced and novice observers and its correlation with the error in measuring the Cobb angle and determining the length of the scoliotic curves. Using the TraumaMeter v.
View Article and Find Full Text PDFInstability is a common cause of (total knee arthroplasty) TKA failure, which can be prevented by achieving proper gap balance during surgery. There is no consensus on the ideal gap balance in TKA, and different alignment philosophies result in varying soft-tissue tightness. Traditional TKA aims for symmetric compartment balance, while kinematic alignment (KA) restores anatomy and accepts asymmetric flexion gaps.
View Article and Find Full Text PDFThe elbow is one of the most commonly dislocated joints. While conservative management is frequently performed for simple elbow dislocations, the importance of primary surgical treatment is still undetermined. However, promising results have been reached after surgical repair.
View Article and Find Full Text PDFRecent advances allow the use of Augmented Reality (AR) for many medical procedures. AR via optical navigators to aid various knee surgery techniques (e.g.
View Article and Find Full Text PDFThe aims of this study were to evaluate the outcomes of patients undergoing kinematic alignment (KA) robot-assisted (RA) total knee arthroplasty (TKA) with and without preoperative fixed flexion contracture (FFC) and address whether additional resection of the proximal tibia is required to address FFC. A retrospective review from 147 consecutive patients who received an RA-TKA with KA and a minimum one-year follow-up was performed. Preop and postop clinical and surgical data were collected.
View Article and Find Full Text PDFA shallow sulcus characterizes trochlear dysplasia (TD) of the femoral trochlea, which can lead to chronic pain or instability of the patellofemoral joint. Breech presentation at birth has been identified as a risk factor for developing this condition, which an ultrasound can identify early. Early treatment could be considered at this stage, given the potential for remodelling in these skeletally immature patients.
View Article and Find Full Text PDFComputer technologies play a crucial role in orthopaedic surgery and are essential in personalising different treatments. Recent advances allow the usage of augmented reality (AR) for many orthopaedic procedures, which include different types of knee surgery. AR assigns the interaction between virtual environments and the physical world, allowing both to intermingle (AR superimposes information on real objects in real-time) through an optical device and allows personalising different processes for each patient.
View Article and Find Full Text PDFExpert Rev Med Devices
June 2022
Introduction: Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) surgery was initially developed to increase accuracy. The potential PSI benefits have expanded in the last decade, and other advantages have been published. However, different authors are critical of PSI and argue that the advantages are not such and do not compensate for the extra cost.
View Article and Find Full Text PDFThe Cobb angle value is a critical parameter for evaluating adolescent idiopathic scoliosis (AIS) patients. This study aimed to evaluate a software’s validity and absolute reliability to determine the Cobb angle in AIS digital X-rays, with two different degrees of experienced observers. Four experts and four novice evaluators measured 35 scoliotic curves with the software on three separate occasions, one month apart.
View Article and Find Full Text PDFBackground: Axial vertebral rotation and Cobb's angle are essential parameters for analysing adolescent idiopathic scoliosis. This study's scope evaluates the validity and absolute reliability of application software based on a new mathematical equation to determine the axial vertebral rotation in digital X-rays according to Raimondi's method in evaluators with different degrees of experience.
Methods: Twelve independent evaluators with different experience levels measured 33 scoliotic curves in 21 X-rays with the software on three separate occasions, separated one month.
The posterior condylar offset (PCO) has been proposed as a determinant of a postoperative range of motion after total knee arthroplasty, although there is no consensus. This study aimed to demonstrate the error introduced by forcing the femoral rotation to overlap both condyles for the "true" lateral X-ray projection for the PCO measurement. We hypothesize that the angular discrepancy between the posterior femoral cortical reference plane and the posterior condylar axis plane due to rotation invalidates the acquisition of reliable measurements on X-rays.
View Article and Find Full Text PDFThere have been remarkable advances in knee replacement surgery over the last few decades. One of the concerns continues to be the accuracy in achieving the desired alignment. Patient-specific instrumentation (PSI) was developed to increase component placement accuracy, but the available evidence is not conclusive.
View Article and Find Full Text PDFPurpose: Several studies have been carried out, and there is no classification for proximal humeral fractures (PHF) exempted from variability in interpretation and with questioned reliability. In the present study, we investigated the 'absolute diagnostic reliability' of the most currently used classifications for PHFs on a single anterior-posterior X-ray shoulder image.
Methods: Six orthopaedic surgeons, with varying levels of experience in shoulder pathology, evaluated radiographs from 30 proximal humeral fractures, according to the 'absolute reliability' criteria.
Individualized pre-operative assessment of the patterns of the lower extremity anatomy and deformities in patients undergoing total knee arthroplasty seems essential for a successful surgery. In the present study, we investigated the relationship among the coronal alignment and the rotational profile of the lower extremities in the Caucasian population with end-stage knee osteoarthritis. We conducted a prospective study of 385 knees that underwent a pre-operative three-dimensional computed tomography-based model.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
September 2021
Purpose: The aim of the study was to translate and validate the English version of the 'Knee Society Knee Scoring System' developed in 2011 (2011 KSS) into Spanish. This new KSS version considers patient satisfaction and expectations before and after knee arthroplasty. Moreover, the questionnaire allows a better characterization of a younger and more diverse population.
View Article and Find Full Text PDFPatient-specific instrumentation (PSI) has been introduced to simplify and make total knee arthroplasty (TKA) surgery more precise, effective, and efficient. We performed this study to determine whether the postoperative coronal alignment is related to preoperative deformity when computed tomography (CT)-based PSI is used for TKA surgery, and how the PSI approach compares with deformity correction obtained with conventional instrumentation. We analyzed pre- and post-operative full length standing hip-knee-ankle (HKA) X-rays of the lower limb in both groups using a convention > 180 degrees for valgus alignment and < 180 degrees for varus alignment.
View Article and Find Full Text PDFIntroduction: Accuracy in the placement of components in revision total knee arthroplasty (R-TKA) surgery is sometimes challenging. The applicability of patient‑specific instruments (PSI) in knee surgery has progressively expanded to types of surgery other than primary arthroplasty. Could this assistive technology be used to facilitate accurate R-TKA surgery? The aim of the current manuscript is to describe this new application of PSI for revision of TKA-to-TKA and to provide a step-by-step technical guideline for use.
View Article and Find Full Text PDFExpert Rev Pharmacoecon Outcomes Res
April 2021
Background: We aimed to analyze the impact of two different types of surgical instrumentation (conventional manual instrumentation (CI) and patient-specific instrumentation (PSI)) on length of stay (LOS) and objectify differences in cost. We hypothesized that there are no differences in the LOS and cost due to the instrumentation system used.
Research Design And Methods: LOS was registered using inpatient admission data provided by the Institutional Management Control Department.
Background: The aim of the study was to determine any discrepancies among preoperative full-leg standing radiographs (LLR) and supine non-weight-bearing computed tomography (CT)-scan-based three-dimensional (3D) models in the assessment of the lower limb alignment prior to total knee arthroplasty (TKA) and answer the question of whether the LLR study can be obviated in preoperative planning when TKA is performed with patient-specific instrumentation (PSI).
Methods: LLR and CT-scan-based 3D models of 227 knees (183 patients) were measured. LLR data was then compared to 3D alignment data used to design the PSI for TKA surgery.
The ability to predict accurate sizing of the implant components for total knee arthroplasty surgery can have several benefits in the operating room, in terms of simplifying the workflow and reducing the number of required instrument trays. Planning on a three-dimensional (3D) virtual model can be used to predict size. The aim of this study was to quantify the accuracy of the surgeon-validated plan prediction on a computed tomography (CT)-based system.
View Article and Find Full Text PDFIntroduction: Total knee arthroplasty (TKA) is one of the most commonly performed orthopedic procedures. During the past decade, patient-specific instrumentation (PSI) has been commercially introduced in order to simplify and make TKA surgery more effective, precise and efficient than conventional mechanical instrumentation (CI) and computer-assisted surgery (CAS). Nevertheless, there are critical arguments against PSI for routine use.
View Article and Find Full Text PDFIntroduction: The aim of the present study was to compare a silicone ring tourniquet (SRT) and a classic pneumatic cuff tourniquet (PT) in patients undergoing total knee replacement. We have compared the impact on the glycolytic activity caused by the ischaemia applied to the limb during the surgery.
Material And Methods: 140 patients that underwent total knee arthroplasty (TKA) were randomised in two groups.