Purpose: Brachytherapy (BT) with iodine-125 (I) seeds is effective in low- and intermediate-risk prostate carcinoma, with fewer side effects compared to other techniques, but relapses increase in long-term. In the present paper, 10-year biochemical relapse-free survival (BRFS) results are presented.
Material And Methods: Between 2007 and 2016, 706 patients were treated with real-time technique using Bard-ProLink™ system.
In OECD (Organization for Economic Co-operation and Development) countries, cancer is one of the main causes of death, lung cancer being one of the most aggressive. There are several techniques for the treatment of lung cancer, among which radiotherapy is one of the most effective and least invasive for the patient. However, it has associated difficulties due to the moving target tumor.
View Article and Find Full Text PDFIntroduction And Objectives: To evaluate the results of local control and complications in the treatment of vestibular schwannoma treated with radiation.
Methods: A retrospective study of 194 patients diagnosed with vestibular schwannoma, treated consecutively with radiation (either stereotactic radiosurgery or fractionated radiotherapy) from 1997 to 2012. We analyze the local control of tumors, as well as secondary complications to treatment with radiation.
Purpose: To compare the use of high-dose-rate (HDR) brachytherapy (BT) in patients with lip carcinoma with a former series previously treated with low-dose-rate (LDR) BT.
Methods And Materials: Ninety-nine patients treated with LDR-BT were compared with 104 patients treated with HDR-BT. Distribution by stage was 53.
Purpose: We present the results of a prospective ten-year follow-up study to prove the effectiveness of a single fraction of 192-Ir high-dose-rate (HDR) brachytherapy (BT) as a boost.
Patients And Methods: Between 1999 and 2000, 84 consecutive patients with invasive breast carcinoma, with over 4 mm free margins after conservative surgery, were treated. All cases were stages T1-2, except for one case, a stage T3, 81% pN0, 19% pN1-2.
Purpose: The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapted to High Dose Rate (HDR).
View Article and Find Full Text PDFPurpose: To obtain the absolute dose-rate distribution in liquid water for all six cup-shaped Leipzig applicators by means of an experimentally validated Monte Carlo (MC) code. These six applicators were used in high-dose-rate (HDR) afterloaders with the "classic" and v2 (192)Ir sources. The applicators have an inner diameter of 1, 2, and 3 cm, with the source traveling parallel or perpendicular to the contact surface.
View Article and Find Full Text PDFWe present 39 patients with lip carcinoma treated with HDR, (needles) with 5-5.5 Gy per 8-10 fractions b.i.
View Article and Find Full Text PDF