Publications by authors named "Vessela Krasteva"

Objective: This study involving automated external defibrillators (AEDs) in early treatment of refibrillation aims to evaluate the performance of a new shock advisory system (SAS) during chest compressions (CC) in out-of-hospital cardiac arrest (OHCA) patients.

Methods: This work focuses on AED SAS performance as a secondary outcome of DEFI 2022 clinical prospective study, which included first-analysis shockable OHCA patients. SAS employs the Analyze Whilst Compressing (AWC) algorithm to interact with both cardiopulmonary resuscitation (CPR) and shock advice by conditional operation of two-stage ECG analysis in presence or absence of chest compressions.

View Article and Find Full Text PDF

The aim of this study is to address the challenge of 12-lead ECG delineation by different encoder-decoder architectures of deep neural networks (DNNs). This study compares four concepts for encoder-decoders based on a fully convolutional architecture (CED-Net) and its modifications with a recurrent layer (CED-LSTM-Net), residual connections between symmetrical encoder and decoder feature maps (CED-U-Net), and sequential residual blocks (CED-Res-Net). All DNNs transform 12-lead representative beats to three diagnostic ECG intervals (P-wave, QRS-complex, QT-interval) used for the global delineation of the representative beat (P-onset, P-offset, QRS-onset, QRS-offset, T-offset).

View Article and Find Full Text PDF

Research of novel biosignal modalities with application to remote patient monitoring is a subject of state-of-the-art developments. This study is focused on sonified ECG modality, which can be transmitted as an acoustic wave and received by GSM (Global System for Mobile Communications) microphones. Thus, the wireless connection between the patient module and the cloud server can be provided over an audio channel, such as a standard telephone call or audio message.

View Article and Find Full Text PDF

Ambulatory 24-72 h Holter ECG monitoring is recommended for patients with suspected arrhythmias, which are often transitory and might remain unseen in resting standard 12-lead ECG. Holter manufacturers provide software diagnostic tools to assist clinicians in evaluating these large amounts of data. Nevertheless, the identification of short arrhythmia events and differentiation of the arrhythmia type might be a problem in limited Holter ECG leads.

View Article and Find Full Text PDF

This study aims to present a novel deep learning algorithm for a sliding shock advisory decision during cardiopulmonary resuscitation (CPR) and its performance evaluation as a function of the cumulative hands-off time. We retrospectively used 13,570 CPR episodes from out-of-hospital cardiac arrest (OHCA) interventions reviewed in a period of interest from 30 s before to 10 s after regular analysis of automated external defibrillators (AEDs). Three convolutional neural networks (CNNs) with raw ECG input (duration of 5, 10, and 15 s) were applied for the shock advisory decision during CPR in 26 sequential analyses shifted by 1 s.

View Article and Find Full Text PDF

This study investigates the use of atrioventricular (AV) synchronization as an important diagnostic criterion for atrial fibrillation and flutter (AF) using one to twelve ECG leads. Heart rate, lead-specific AV conduction time, and P-/f-wave amplitude were evaluated by three representative ECG metrics (mean value, standard deviation), namely RR-interval (RRi-mean, RRi-std), PQ-interval (PQi-mean, PQI-std), and PQ-amplitude (PQa-mean, PQa-std), in 71,545 standard 12-lead ECG records from the six largest PhysioNet CinC Challenge 2021 databases. Two rhythm classes were considered (AF, non-AF), randomly assigning records into training (70%), validation (20%), and test (10%) datasets.

View Article and Find Full Text PDF

Considering the significant burden to patients and healthcare systems globally related to atrial fibrillation (AF) complications, the early AF diagnosis is of crucial importance. In the view of prominent perspectives for fast and accurate point-of-care arrhythmia detection, our study optimizes an artificial neural network (NN) classifier and ranks the importance of enhanced 137 diagnostic ECG features computed from time and frequency ECG signal representations of short single-lead strips available in 2017 Physionet/CinC Challenge database. Based on hyperparameters' grid search of densely connected NN layers, we derive the optimal topology with three layers and 128, 32, 4 neurons per layer (DenseNet-3@128-32-4), which presents maximal F1-scores for classification of Normal rhythms (0.

View Article and Find Full Text PDF

A few randomized trials have compared impedance-compensated biphasic defibrillators in clinical use. We aim to compare pulsed biphasic (PB) and biphasic truncated exponential (BTE) waveforms in a non-inferiority cardioversion (CVS) study. This was a prospective monocentric randomized clinical trial.

View Article and Find Full Text PDF

High performance of the shock advisory analysis of the electrocardiogram (ECG) during cardiopulmonary resuscitation (CPR) in out-of-hospital cardiac arrest (OHCA) is important for better management of the resuscitation protocol. It should provide fewer interruptions of chest compressions (CC) for non-shockable organized rhythms (OR) and Asystole, or prompt CC stopping for early treatment of shockable ventricular fibrillation (VF). Major disturbing factors are strong CC artifacts corrupting raw ECG, which we aimed to analyze with optimized end-to-end convolutional neural network (CNN) without pre-filtering or additional sensors.

View Article and Find Full Text PDF

The synchronized firings of active motor units (MUs) increase the oscillations of muscle force, observed as physiological tremor. This study aimed to investigate the effects of synchronizing the firings within three types of MUs (slow-S, fast resistant to fatigue-FR, and fast fatigable-FF) on the muscle force production using a mathematical model of the rat medial gastrocnemius muscle. The model was designed based on the actual proportion and physiological properties of MUs and motoneurons innervating the muscle.

View Article and Find Full Text PDF

Objective: The aim of this study was to present new combination of algorithms for rhythm analysis during cardiopulmonary resuscitation (CPR) in automated external defibrillators (AED), called Analyze Whilst Compressing (AWC), designed for decreasing pre-shock pause and early stopping of chest compressions (CC) for treating refibrillation.

Methods: Two stages for AED rhythm analysis were presented, namely, "Standard Analysis Stage" (conventional shock-advisory analysis run over 5 s after CC interruption every two minutes) and "AWC Stage" (two-step sequential analysis process during CPR). AWC steps were run in presence of CC (Step1), and if shockable rhythm was detected then a reconfirmation step was run in absence of CC (Step2, analysis duration 5 s).

View Article and Find Full Text PDF

Deep neural networks (DNN) are state-of-the-art machine learning algorithms that can be learned to self-extract significant features of the electrocardiogram (ECG) and can generally provide high-output diagnostic accuracy if subjected to robust training and optimization on large datasets at high computational cost. So far, limited research and optimization of DNNs in shock advisory systems is found on large ECG arrhythmia databases from out-of-hospital cardiac arrests (OHCA). The objective of this study is to optimize the hyperparameters (HPs) of deep convolutional neural networks (CNN) for detection of shockable (Sh) and nonshockable (NSh) rhythms, and to validate the best HP settings for short and long analysis durations (2-10 s).

View Article and Find Full Text PDF

Background: Despite the widespread use of biphasic waveforms for cardioversion and defibrillation, the efficacy and safety of shocks has only been compared in a few studies.

Methods: This retrospective study aims at comparing the efficacy and safety of biphasic truncated exponential (BTE) pulsed energy (PE) waveform with a BTE low energy (LE) waveform for cardioversion of atrial fibrillation (AF) and atrial flutter (AFL). The treatment energies were following an escalating protocol for PE waveform (120-200-200J in AF and 30-120-200J in AFL) and LE waveform (100-200-200J in AF and 30-100-200J in AFL).

View Article and Find Full Text PDF

Electrode reversal errors in standard 12-lead electrocardiograms (ECG) can produce significant ECG changes and, in turn, misleading diagnoses. Their detection is important but mostly limited to the design of criteria using ECG databases with simulated reversals, without Wilson's central terminal (WCT) potential change. This is, to the best of our knowledge, the first study that presents an algebraic transformation for simulation of all possible ECG cable reversals, including those with displaced WCT, where most of the leads appear with distorted morphology.

View Article and Find Full Text PDF

Objective: This study participated in the 2017 PhysioNet/CinC Challenge dedicated to the classification of atrial fibrillation (AF), normal sinus rhythm (Normal), other arrhythmia (Other) and strong noise, using single-lead electrocardiogram (ECG) recordings with a duration  <60 s. The aim is to apply a linear threshold-based strategy for arrhythmia classification, ranking the most powerful time domain ECG features that could be easily reproduced on any platform.

Approach: An algorithm for time domain ECG analysis was designed to extract 44 features with focus on the following: noise detection; heart rate variability (HRV) analysis; beat morphology analysis and delineation of P-, QRS-, and T-waves in the robust average beat; detection of atrial activity by the presence of P-waves in the average beat and atrial fibrillatory waves (f-waves) during TQ intervals.

View Article and Find Full Text PDF

Objective: This study aims to validate the 12-lead electrocardiogram (ECG) as a biometric modality based on two straightforward binary QRS template matching characteristics. Different perspectives of the human verification problem are considered, regarding the optimal lead selection and stability over sample size, gender, age, heart rate (HR).

Methods: A clinical 12-lead resting ECG database, including a population of 460 subjects with two-session recordings (>1 year apart) is used.

View Article and Find Full Text PDF

Human identification (ID) is a biometric task, comparing single input sample to many stored templates to identify an individual in a reference database. This paper aims to present the perspectives of personalized heartbeat pattern for reliable ECG-based identification. The investigations are using a database with 460 pairs of 12-lead resting electrocardiograms (ECG) with 10-s durations recorded at time-instants T1 and T2 > T1 + 1 year.

View Article and Find Full Text PDF

Background: Electrocardiogram (ECG)-based biometrics relies on the most stable and unique beat patterns, i.e. those with maximal intra-subject and minimal inter-subject waveform differences seen from different leads.

View Article and Find Full Text PDF

Background: Electrocardiogram (ECG) biometrics is an advanced technology, not yet covered by guidelines on criteria, features and leads for maximal authentication accuracy.

Objective: This study aims to define the minimal set of morphological metrics in 12-lead ECG by optimization towards high reliability and security, and validation in a person verification model across a large population.

Methods: A standard 12-lead resting ECG database from 574 non-cardiac patients with two remote recordings (>1year apart) was used.

View Article and Find Full Text PDF

Background And Objective: A crucial factor for proper electrocardiogram (ECG) interpretation is the correct electrode placement in standard 12-lead ECG and extended 16-lead ECG for accurate diagnosis of acute myocardial infarctions. In the context of optimal patient care, we present and evaluate a new method for automated detection of reversals in peripheral and precordial (standard, right and posterior) leads, based on simple rules with inter-lead correlation dependencies.

Methods: The algorithm for analysis of cable reversals relies on scoring of inter-lead correlations estimated over 4s snapshots with time-coherent data from multiple ECG leads.

View Article and Find Full Text PDF

False intensive care unit (ICU) alarms induce stress in both patients and clinical staff and decrease the quality of care, thus significantly increasing both the hospital recovery time and rehospitalization rates. In the PhysioNet/CinC Challenge 2015 for reducing false arrhythmia alarms in ICU bedside monitor data, this paper validates the application of a real-time arrhythmia detection library (ADLib, Schiller AG) for the robust detection of five types of life-threatening arrhythmia alarms. The strength of the application is to give immediate feedback on the arrhythmia event within a scan interval of 3 s-7.

View Article and Find Full Text PDF

This study presents a 2-stage heartbeat classifier of supraventricular (SVB) and ventricular (VB) beats. Stage 1 makes computationally-efficient classification of SVB-beats, using simple correlation threshold criterion for finding close match with a predominant normal (reference) beat template. The non-matched beats are next subjected to measurement of 20 basic features, tracking the beat and reference template morphology and RR-variability for subsequent refined classification in SVB or VB-class by Stage 2.

View Article and Find Full Text PDF

This paper presents a system for detection of the most common noise types seen on the electrocardiogram (ECG) in order to evaluate whether an episode from 12-lead ECG is reliable for diagnosis. It implements criteria for estimation of the noise corruption level in specific frequency bands, aiming to identify the main sources of ECG quality disruption, such as missing signal or limited dynamics of the QRS components above 4 Hz; presence of high amplitude and steep artifacts seen above 1 Hz; baseline drift estimated at frequencies below 1 Hz; power-line interference in a band ±2 Hz around its central frequency; high-frequency and electromyographic noises above 20 Hz. All noise tests are designed to process the ECG series in the time domain, including 13 adjustable thresholds for amplitude and slope criteria which are evaluated in adjustable time intervals, as well as number of leads.

View Article and Find Full Text PDF

Aims: Shortening hands-off intervals can improve benefits from defibrillation. This study presents the performance of a shock advisory system (SAS), which aims to decrease the pre-shock pauses by triggering fast rhythm analysis at minimal delay after end of chest compressions (CC).

Methods: The SAS is evaluated on a database of 1301 samples from 311 out-of-hospital cardiac arrests (OHCA) from automated external defibrillators (AEDs).

View Article and Find Full Text PDF

This study aims to contribute to the scarce data available about the abilities of untrained lay persons to perform hands-only cardio-pulmonary resuscitation (CPR) on a manikin and the improvement of their skills during training with an autonomous CPR feedback device. The study focuses on the following questions: (i) Is there a need for such a CPR training device? (ii) How adequate are the embedded visual feedback and audio guidance for training of lay persons who learn and correct themselves in real time without instructor guidance? (iii) What is the achieved effect of only 3 min of training? This is a prospective study in which 63 lay persons (volunteers) received a debriefing to basic life support and then performed two consecutive 3 min trials of hands-only CPR on a manikin. The pre-training skills of the lay persons were tested in trial 1.

View Article and Find Full Text PDF