Publications by authors named "Versteeg E"

Background: Canada has the fourth highest per capita rate of opioid prescriptions in the world, contributing to the country's opioid crisis. Due to both their pain-relieving and euphoric properties, opioids can be highly addictive, leading to potential overdose and death. Deprescription is an endorsed and organized method of discontinuing a drug but very little is known about the barriers that Canadian physicians face when attempting to deprescribe opioids, particularly those who practice in rural areas (which have some of the highest rates of opioid users).

View Article and Find Full Text PDF
Article Synopsis
  • A new 3D MR-STAT protocol was developed to address issues with cerebrospinal fluid (CSF) pulsation artifacts in brain imaging, which commonly affect image quality.
  • The researchers optimized the sequence to reduce noise and CSF signal, validating its effectiveness using both phantoms and healthy volunteers, resulting in improved quantitative maps without CSF-related distortions.
  • The final protocol demonstrates high-quality imaging with minimal variability across subjects, allowing for rapid and accurate whole-brain relaxometry scans in just 5.5 minutes.
View Article and Find Full Text PDF

Purpose: To demonstrate the feasibility of using a nonlinear gradient field for spatial encoding at the ultrasonic switching frequency of 20 kHz and present a framework to reconstruct data acquired in this way.

Methods: Nonlinear encoding at 20 kHz was realized by using a single-axis silent gradient insert for imaging in the periphery, that, is the nonlinear region, of the gradient field. The gradient insert induces a rapidly oscillating gradient field in the phase-encode direction, which enables nonlinear encoding when combined with a Cartesian readout from the linear whole-body gradients.

View Article and Find Full Text PDF

Purpose: To demonstrate the feasibility and robustness of the Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) framework for fast, high SNR relaxometry at 7T.

Methods: To deploy MR-STAT on 7T-systems, we designed optimized flip-angles using the BLAKJac-framework that incorporates the SAR-constraints. Transmit RF-inhomogeneities were mitigated by including a measured -map in the reconstruction.

View Article and Find Full Text PDF

Purpose: We present a novel silent echo-planar spectroscopic imaging (EPSI) readout, which uses an ultrasonic gradient insert to accelerate MRSI while producing a high spectral bandwidth (20 kHz) and a low sound level.

Methods: The ultrasonic gradient insert consisted of a single-axis (z-direction) plug-and-play gradient coil, powered by an audio amplifier, and produced 40 mT/m at 20 kHz. The silent EPSI readout was implemented in a phase-encoded MRSI acquisition.

View Article and Find Full Text PDF

Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) is a multiparametric quantitative MR framework, which allows for simultaneously acquiring quantitative tissue parameters such as T1, T2, and proton density from one single short scan. A typical two-dimensional (2D) MR-STAT acquisition uses a gradient-spoiled, gradient-echo sequence with a slowly varying RF flip-angle train and Cartesian readouts, and the quantitative tissue maps are reconstructed by an iterative, model-based optimization algorithm. In this work, we design a three-dimensional (3D) MR-STAT framework based on previous 2D work, in order to achieve better image signal-to-noise ratio, higher though-plane resolution, and better tissue characterization.

View Article and Find Full Text PDF

Background: Non-AT-III mediated heparin-resistance during CPB occurs by complex-forming with heparin-binding proteins. Currently, there are no specific recommendations for non-AT-III mediated heparin-resistance.

Case Presentation: We present a fatal case of a 70-yr-old male-patient undergoing cardiac-surgery in which refractory heparin-resistance was observed.

View Article and Find Full Text PDF

The process of wound healing is a tightly controlled cascade of events, where severe skin wounds are resolved via scar tissue. This fibrotic response may be diminished by applying anti-fibrotic factors to the wound, thereby stimulating regeneration over scarring. The development of tunable biomaterials that enable spatiotemporal control over the release of anti-fibrotics would greatly benefit wound healing.

View Article and Find Full Text PDF

Objectives: Acoustic noise in magnetic resonance imaging (MRI) negatively impacts patients. We assessed a silent gradient coil switched at 20 kHz combined with a T-weighted magnetisation prepared rapid gradient-echo (MPRAGE) sequence at 7 T.

Methods: Five healthy subjects (21-29 years; three females) without previous 7-T MRI experience underwent both a quiet MPRAGE (Q-MPRAGE) and conventional MPRAGE (C-MPRAGE) sequence twice.

View Article and Find Full Text PDF

In our aging society, the number of patients suffering from poorly healing bone defects increases. Bone morphogenetic proteins (BMPs) are used in the clinic to promote bone regeneration. However, poor control of BMP delivery and thus activity necessitates high doses, resulting in adverse effects and increased costs.

View Article and Find Full Text PDF

Iatrogenic preterm premature rupture of fetal membranes (iPPROM) after fetal surgery remains a strong trigger for premature birth. As fetal membrane defects do not heal spontaneously and amniotic fluid leakage and chorioamniotic membrane separation may occur, we developed a biocompatible, fetoscopically-applicable collagen plug with shape memory to prevent leakage. This plug expands directly upon employment and seals fetal membranes, hence preventing amniotic fluid leakage and potentially iPPROM.

View Article and Find Full Text PDF

Purpose: To characterize the acceleration capabilities of a silent head insert gradient axis that operates at the inaudible frequency of 20 kHz and a maximum gradient amplitude of 40 mT/m without inducing peripheral nerve stimulation.

Methods: The silent gradient axis' acquisitions feature an oscillating gradient in the phase-encoding direction that is played out on top of a cartesian readout, similarly as done in Wave-CAIPI. The additional spatial encoding fills k-space in readout lanes allowing for the acquisition of fewer phase-encoding steps without increasing aliasing artifacts.

View Article and Find Full Text PDF

Teleost fishes occupy a range of ecosystem, and habitat types subject to large seasonal fluctuations. Temperate fishes, in particular, survive large seasonal shifts in temperature, light availability, and access to certain habitats. Mobile species such as lake trout () can behaviorally respond to seasonal variation by shifting their habitat deeper and further offshore in response to warmer surface water temperatures during the summer.

View Article and Find Full Text PDF

Purpose: A novel silent imaging method is proposed that combines a gradient insert oscillating at the inaudible frequency 20 kHz with slew rate-limited gradient waveforms to form a silent gradient axis that enable quiet and fast imaging.

Methods: The gradient insert consisted of a plug-and-play (45 kg) single axis z-gradient, which operated as an additional fourth gradient axis. This insert was made resonant using capacitors and combined with an audio amplifier to allow for operation at 20 kHz.

View Article and Find Full Text PDF

Background And Purpose: The restricted bore diameter of current simultaneous positron emission tomography/magnetic resonance imaging (PET/MRI) systems can be an impediment to achieving similar patient positioning during PET/MRI planning and radiotherapy. Our goal was to evaluate the B transmit (B ) uniformity, B efficiency, and specific absorption rate (SAR) of a novel radiofrequency (RF) body coil design, in which RF shielded PET detectors were integrated with the specific aim of enabling a wide-bore PET/MRI system.

Materials And Methods: We designed and constructed a wide-bore PET/MRI RF body coil to be integrated with a clinical MRI system.

View Article and Find Full Text PDF

The goal of this study was to introduce and evaluate the performance of a lightweight, high-performance, single-axis (z-axis) gradient insert design primarily intended for high-resolution functional magnetic resonance imaging, and aimed at providing both ease of use and a boost in spatiotemporal resolution. The optimal winding positions of the coil were obtained using a genetic algorithm with a cost function that balanced gradient performance (minimum 0.30 mT/m/A) and field linearity (≥16 cm linear region).

View Article and Find Full Text PDF

Background And Purpose: Cerebral MR imaging in infants is usually performed with a field strength of up to 3T. In adults, a growing number of studies have shown added diagnostic value of 7T MR imaging. 7T MR imaging might be of additional value in infants with unexplained seizures, for example.

View Article and Find Full Text PDF

Heparan sulfate (HS) is a linear polysaccharide with high structural diversity. Different HS epitopes have been detected and localized using single chain variable fragment (scFv) antibodies from a 'single pot' phage display library containing a randomized complementarity determining region of the heavy chain (CDR3). In this study, we created a new library containing anti-HS scFvs that all harbor a dp-38 heavy chain segment where the CDR3 region was engineered to contain the XBBXBX heparin binding consensus site (X = any amino acid, B = R, K or H).

View Article and Find Full Text PDF

Glycosaminoglycans (GAGs) are known to play pivotal roles in physiological processes and pathological conditions. To study interactions of GAGs with proteins, immobilization of GAGs is often required. Current methodologies for immobilization involve modification of GAGs and/or surfaces, which can be time-consuming and may involve specialized equipment.

View Article and Find Full Text PDF

Glycosaminoglycans are important for cell signaling and therefore for proper embryonic development and adult homeostasis. Expressions of genes involved in proteoglycan/glycosaminoglycan (GAG) metabolism and of genes coding for growth factors known to bind GAGs were analyzed during skin development by microarray analysis and real time quantitative PCR. GAG related genes were organized in six categories based on their role in GAG homeostasis, (1) production of precursor molecules, (2) production of core proteins, (3) synthesis of the linkage region, (4) polymerization, (5) modification, and (6) degradation of the GAG chain.

View Article and Find Full Text PDF

Technologies to sequence nucleic acids/proteins are widely available, but straightforward methodologies to sequence complex polysaccharides are lacking. We here put forward a strategy to sequence glycosaminoglycans, long linear polysaccharides involved in many biochemical processes. The method is based on the covalent immobilization and (immuno)chemical characterization of only those size-separated saccharides that harbor the original reducing end of the full-length chain.

View Article and Find Full Text PDF

Introduction: Tissue engineering may become an alternative to current bladder augmentation techniques. Large scaffolds are needed for clinically significant augmentation, but can result in fibrosis and graft shrinkage. The purpose of this study was to investigate the use of multiple scaffolds instead of one large scaffold, to enhance bladder tissue regeneration and bladder capacity.

View Article and Find Full Text PDF

Identifying collagen produced de novo by cells in a background of purified collagenous biomaterials poses a major problem in for example the evaluation of tissue-engineered constructs and cell biological studies to tumor dissemination. We have developed a universal strategy to detect and localize newly deposited collagen based on its inherent association with dermatan sulfate. The method is applicable irrespective of host species and collagen source.

View Article and Find Full Text PDF

Unlabelled: In skeletal muscle, the stem cell niche is important for controlling the quiescent, proliferation and differentiation states of satellite cells, which are key for skeletal muscle regeneration after wounding. It has been shown that type I collagen, often used as 3D-scaffolds for regenerative medicine purposes, impairs myoblast differentiation. This is most likely due to the absence of specific extracellular matrix proteins providing attachment sites for myoblasts and/or myotubes.

View Article and Find Full Text PDF

Dermatan sulfate (DS), also known as chondroitin sulfate (CS)-B, is a member of the linear polysaccharides called glycosaminoglycans (GAGs). The expression of CS/DS and DS proteoglycans is increased in several fibrotic renal diseases, including interstitial fibrosis, diabetic nephropathy, mesangial sclerosis and nephrosclerosis. Little, however, is known about structural alterations in DS in renal diseases.

View Article and Find Full Text PDF