A universal power-law scaling z[over ¯]∝E^{0.4} in the correlation between the average ion charge state z[over ¯] and kinetic energy E in expanding laser-driven tin plasmas is identified. Universality here refers to an insensitivity to all experimental conditions: target geometry, expansion direction, laser wavelength, and power density.
View Article and Find Full Text PDFWe present simultaneous 1D imaging and broadband spectroscopy of a laser-produced plasma (LPP) source of extreme ultraviolet light, using a tapered zone plate that is matched to the dispersion of a transmission grating. We describe the design and fabrication of the zone plates in the 5-80 nm wavelength regime with designed spatial resolution of ∼10 µm and spectral resolution of ∼0.8 nm.
View Article and Find Full Text PDFA laser system generating high-energy pulses at 2-µm wavelength with pulse widths tunable from 10-24 ns is described. It comprises an optical parametric oscillator that generates mJ-level signal seed radiation and an optical parametric amplifier that boosts the output to 800 mJ of combined signal and idler when pumped with 2 J pulses of 1064-nm laser light. The system operated with KTP crystals and running at 10 Hz repetition rate is characterized in the spatial, temporal, and spectral domains.
View Article and Find Full Text PDFWe present the results of the calibration of a channeltron-based electrostatic analyzer operating in time-of-flight mode (ESA-ToF) using tin ions resulting from laser-produced plasma, over a wide range of charge states and energies. Specifically, the channeltron electron multiplier detection efficiency and the spectrometer resolution are calibrated, and count rate effects are characterized. With the obtained overall response function, the ESA-ToF is shown to accurately reproduce charge-integrated measurements separately and simultaneously obtained from a Faraday cup (FC), up to a constant factor the finding of which enables absolute cross-calibration of the ESA-ToF using the FC as an absolute benchmark.
View Article and Find Full Text PDFAn experimental study of laser-produced plasmas is performed by irradiating a planar tin target by laser pulses, of 4.8 ns duration, produced from a KTP-based 2-µm-wavelength master oscillator power amplifier. Comparative spectroscopic investigations are performed for plasmas driven by 1-µm- and 2-µm-wavelength pulsed lasers, over a wide range of laser intensities spanning 0.
View Article and Find Full Text PDFThe afterglow emission from Nd:YAG-laser-produced microdroplet-tin plasma is investigated, with a focus on analyzing Stark effect phenomena and the dynamical evolution of the plasma. Time- and space-resolved optical imaging spectroscopy is performed on 11 lines from Sn i-iv ions, in the 315-425-nm wavelength range. Stark shift-to-width ratios serve as the basis for unambiguous experimental tests of atomic physics theory predictions.
View Article and Find Full Text PDFExtreme ultraviolet (EUV) lithography is currently entering high-volume manufacturing to enable the continued miniaturization of semiconductor devices. The required EUV light, at 13.5 nm wavelength, is produced in a hot and dense laser-driven tin plasma.
View Article and Find Full Text PDFPreparing highly charged ions (HCIs) in a cold and strongly localized state is of particular interest for frequency metrology and tests of possible spatial and temporal variations of the fine structure constant. Our versatile preparation technique is based on the generic modular combination of a pulsed ion source with a cryogenic linear Paul trap. Both instruments are connected by a compact beamline with deceleration and precooling properties.
View Article and Find Full Text PDFWe measure optical spectra of Nd-like W, Re, Os, Ir, and Pt ions of particular interest for studies of a possibly varying fine-structure constant. Exploiting characteristic energy scalings we identify the strongest lines, confirm the predicted 5s-4f level crossing, and benchmark advanced calculations. We infer two possible values for optical M2/E3 and E1 transitions in Ir^{17+} that have the highest predicted sensitivity to a variation of the fine-structure constant among stable atomic systems.
View Article and Find Full Text PDFControl over the motional degrees of freedom of atoms, ions, and molecules in a field-free environment enables unrivalled measurement accuracies but has yet to be applied to highly charged ions (HCIs), which are of particular interest to future atomic clock designs and searches for physics beyond the Standard Model. Here, we report on the Coulomb crystallization of HCIs (specifically (40)Ar(13+)) produced in an electron beam ion trap and retrapped in a cryogenic linear radiofrequency trap by means of sympathetic motional cooling through Coulomb interaction with a directly laser-cooled ensemble of Be(+) ions. We also demonstrate cooling of a single Ar(13+) ion by a single Be(+) ion-the prerequisite for quantum logic spectroscopy with a potential 10(-19) accuracy level.
View Article and Find Full Text PDFThe preparation of cold molecules is of great importance in many contexts, such as fundamental physics investigations, high-resolution spectroscopy of complex molecules, cold chemistry and astrochemistry. One versatile and widely applied method to cool molecules is helium buffer-gas cooling in either a supersonic beam expansion or a cryogenic trap environment. Another more recent method applicable to trapped molecular ions relies on sympathetic translational cooling, through collisional interactions with co-trapped, laser-cooled atomic ions, into spatially ordered structures called Coulomb crystals, combined with laser-controlled internal-state preparation.
View Article and Find Full Text PDFWe present a method to measure the decay rate of the first excited vibrational state of polar molecular ions that are part of a Coulomb crystal in a cryogenic linear Paul trap. Specifically, we have monitored the decay of the |ν = 1, J = 1)(X) towards the |ν = 0, J = 0)(X) level in MgH+ by saturated laser excitation of the |ν = 0, J = 2)(X)-|ν = 1, J = 1)(X) transition followed by state selective resonance enhanced two-photon dissociation out of the |ν = 0, J=2)(X) level. The experimentally observed rate of 6.
View Article and Find Full Text PDFStorage and cooling of highly charged ions require ultra-high vacuum levels obtainable by means of cryogenic methods. We have developed a linear Paul trap operating at 4 K capable of very long ion storage times of about 30 h. A conservative upper bound of the H(2) partial pressure of about 10(-15) mbar (at 4 K) is obtained from this.
View Article and Find Full Text PDFA measurement of the final state distribution of the (8)B β decay, obtained by implanting a (8)B beam in a double-sided silicon strip detector, is reported here. The present spectrum is consistent with a recent independent precise measurement performed by our collaboration at the IGISOL facility, Jyväskylä [O. S.
View Article and Find Full Text PDF