Objectives: To determine the ferritin inter-assay differences between three "Conformité Européenne" (CE) marked tests, the impact on reference intervals (RI), and the proportion of individuals with iron deficiency (ID), we used plasma and serum from healthy blood donors (HBD) recruited in three different Switzerland regions.
Design And Methods: Heparinized plasma and serum from HBD were obtained from three different transfusion centers in Switzerland (Fribourg, Geneva, and Neuchatel). One hundred forty samples were recruited per center and per matrix, with a gender ratio of 50%, for a total of 420 HBD samples available per matrix.
Toxicological screening is the analysis of biological samples to detect and identify unknown compounds. The high selectivity and sensitivity of liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) technology provide an attractive alternative to the current methods (LC-UV, GC/MS, etc.).
View Article and Find Full Text PDFAbstract Toxicological screening is the analysis of a biological specimen to detect and identify compounds in patients admitted to the hospital with acute intoxication of unknown origin. The screening of a wide range of toxicologically relevant compounds in biological samples is a serious challenge for clinical laboratories. The high selectivity and sensitivity of liquid chromatography coupled to mass spectrometry or tandem mass spectrometry technology provides an attractive alternative to the current methods.
View Article and Find Full Text PDFAn exhaustive classification of matrix effects occurring when a sample preparation is performed prior to liquid-chromatography coupled to mass spectrometry (LC-MS) analyses was proposed. A total of eight different situations were identified allowing the recognition of the matrix effect typology via the calculation of four recovery values. A set of 198 compounds was used to evaluate matrix effects after solid phase extraction (SPE) from plasma or urine samples prior to LC-ESI-MS analysis.
View Article and Find Full Text PDFThe diversity of experimental workflows involving LC-MS/MS and the extended range of mass spectrometers tend to produce extremely variable spectra. Variability reduces the accuracy of compound identification produced by commonly available software for a spectral library search. We introduce here a new algorithm that successfully matches MS/MS spectra generated by a range of instruments, acquired under different conditions.