Objective: To determine the long-term benefit of the Vibrant Soundbridge (VSB) middle ear implant in patients with severe mixed hearing loss and to compare it with other hearing devices.
Design: A retrospective analysis.
Setting: University-affiliated medical center.
Background: The 2 most frequently used endoscopic methods to treat Zenker's diverticulum are staple-assisted and CO(2) laser esophagodiverticulostomy.
Methods: The study centered around a retrospective evaluation of 107 patients with Zenker's diverticulum who were treated endoscopically by CO(2) laser (n = 72) or staple-assisted diverticulostomy (n = 35).
Results: Patients in the staple-assisted group had a shorter duration of postoperative hospitalization, attributed to earlier oral intake, than patients in the CO(2) laser group.
Objective: To optimize intraoperatively the coupling of the floating mass transducer (FMT) of the Vibrant Soundbridge middle ear implant to the round or oval cochlear window in patients with mixed hearing loss.
Study Design: Intraoperative measurement of objective hearing thresholds using auditory steady state responses (ASSRs).
Setting: Radboud University Nijmegen Medical Centre, tertiary referral hospital.
Ann Otol Rhinol Laryngol
October 2009
Objectives: We evaluated 5 patients who were changed over from a Baha Cordelle to a cochlear implant (CI). Moreover, the level of phoneme score was determined at which a Baha Cordelle user was better helped with a CI.
Methods: We offer descriptive case reports and a retrospective evaluation of speech recognition in Baha Cordelle users and CI users.
Hypothesis: The floating mass transducer (FMT) of the Vibrant Soundbridge (VSB) can be interposed in the middle ear in case of an absent incus.
Background: The VSB is a middle ear implant in which the FMT is attached to the long process of the incus to directly drive the ossicular chain. In this case report, there was gradual deterioration in speech perception after VSB fitting and deterioration in hearing thresholds.
Objectives/hypothesis: To define audiological application criteria for different implantable hearing aid devices.
Study Design: Retrospective study.
Methods: Comparisons were made between aided speech recognition scores obtained at conversational level (65 dB) in patients with the Vibrant Soundbridge (VSB) (n = 22), the Otologics middle ear transducer (MET) (n = 10), conventional hearing aids (behind-the-ears) (n = 47), and cochlear implants (CIs) (n = 123).