The study aimed to assess the agreement between OptoTab SERIES, alternating Cover Test, Modified Thorington test, and Von Graefe method in measuring heterophoria and accommodative convergence over accommodation (AC/A) ratio. In an initial step, heterophoria was assessed at both distance and near in a cohort of 76 healthy young volunteers using the previously described tests. Subsequently, to determine the AC/A ratio, near-vision measurements were repeated with +1.
View Article and Find Full Text PDFThe present study aimed to assess the symptomatic status of Convergence Insufficiency (CI) in university students from 2018 to 2023 considering the educational environment pre- and post-COVID-19 pandemic confinements. A Convergence Insufficiency Symptom Survey (CISS) was conducted annually from 2018 to 2023, excluding 2020, in an initial group of 217 third-year Optics and Optometry degree university student participants. In the final group (178 participants), the statistical differences in CISS scores between years were analysed, both overall and by questionnaire subgroup, along with associations between CISS diagnostic categories before and after 2020.
View Article and Find Full Text PDFObjective: This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort.
Methods: Neophyte CL wearers (n = 44, 21.09 ± 5.
Clinical Relevance: Due to the long-time that wind musicians spend playing their instruments, it is important to investigate if intraocular pressure could be affected by this activity.
Background: To assess the intraocular pressure fluctuations and fluctuations affecting factors in professional wind musicians while playing different tones.
Methods: Thirty professional wind musicians (23.
Purpose To compare intraocular pressure (IOP) values at different time points, both in the total sample and according to iridocorneal angle aperture, to assess whether IOP fluctuations were constant throughout the day, and to examine correlations with other factors. Methods Over a single day, the IOP of 34 volunteers was measured at three-hour intervals from 9:00 a.m.
View Article and Find Full Text PDFObjectives: To compare the values of central corneal thickness, anterior chamber depth (ACD), lens thickness (LT), vitreous length (VL), axial length (AL), and corneal-compensated intraocular pressure performed with and without contact lenses (CL).
Methods: Forty volunteer participants (16 men and 24 women, 24.2±2.
Background: Due to the increasing use of contact lenses (CL) and the interest in ocular and body size relationships, this study aimed to compare measurements from two biometers (contact ultrasonic EchoScan US-800 and non-contact optical Lenstar LS900) with and without CL and to explore the relationship between ocular and body biometric parameters.
Design And Methods: This cross-sectional study measured ocular biometry using two biometers along with their body height and right foot length in 50 participants. Differences between biometry data from the two devices were compared and correlations between ocular and body biometric values were analyzed.
Purpose: Clinicians play a key role in prescribing contact lenses that best suited for fitting which materials had an impact on ocular surface parameters. The present study aimed to evaluate the impact on symptomatology, tear film dynamics and ocular surface integrity of a silicone-hydrogel (Somofilcon-A) and a hydrogel (Omafilcon-A) lens before and after wearing for one week in contact lens neophyte participants.
Methods: A Somofilcon-A and Omafilcon-A were randomly fitted to one or other the eye on an initial group of 28 participants.