Objectives: Real-time monitoring of cochlear function to predict the loss of residual hearing after cochlear implantation is now possible. Current approaches monitor the cochlear microphonic (CM) during implantation from the electrode at the tip of the implant. A drop in CM response of >30% is associated with poorer hearing outcomes.
View Article and Find Full Text PDFObjectives: To determine the Incremental Cost-Utility Ratio (ICUR) of cochlear implantation in the treatment of adult patients with single-sided deafness (SSD) and asymmetric hearing loss (AHL).
Methods: This prospective multicenter pragmatic study including a randomized controlled trial (RCT) enrolled 155 subjects with SSD or AHL. Subjects chose a treatment option between: abstention, Contralateral Routing Of the Signal hearing aids, Bone Conduction Device or Cochlear Implant (CI).
Objective: This study evaluated the diagnostic performances of a tablet-based hearing screening test by assisted-test and self-test modes.
Design/method: Measurements were performed with the SoTone tests in normal hearing and hearing-impaired adult participants using an Android tablet and calibrated Bluetooth headphones. The duration of assisted- and self-test modes were compared.
Introduction: Presbycusis is the physiological decrease in hearing due to advancing age and begins well before the sixth decade. These recommendations recall the principles of early diagnosis of presbycusis and the means of optimal rehabilitation as soon as the first symptoms appear.
Material And Methods: The recommendations are based on a systematic analysis of the literature carried out by a multidisciplinary group of ENT physicians, audiologists, geriatricians and hearing specialists from all over France.
Introduction: Presbycusis is the physiological decrease in hearing due to advancing age and begins well before the sixth decade. These recommendations recall the principles of early diagnosis of presbycusis and the means of optimal rehabilitation as soon as the first symptoms appear.
Material And Methods: The recommendations are based on a systematic analysis of the literature carried out by a multidisciplinary group of doctors and audioprosthetists from all over France.
IEEE Trans Biomed Eng
September 2023
Objective: In this paper, we focus on the carrying out and validation of minimally invasive three-dimensional (3D) ultrasound (US) imaging of the auditory system, which is based on a new miniaturized endoscopic 2D US transducer.
Methods: This unique probe consists of a 18 MHz 24 elements curved array transducer with a distal diameter of 4 mm so it can be inserted into the external auditory canal. Typical acquisition is achieved by rotating such a transducer around its own axis using a robotic platform.
Auditory neuropathy spectrum disorder (ANSD) refers to a range of hearing impairments characterized by an impaired transmission of sound from the cochlea to the brain. This defect can be due to a lesion or defect in the inner hair cell (IHC), IHC ribbon synapse (e.g.
View Article and Find Full Text PDFObjectives: Electrocochleography (ECochG) is emerging as a tool for monitoring cochlear function during cochlear implant (CI) surgery. ECochG may be recorded directly from electrodes on the implant array intraoperatively. For low-frequency stimulation, its amplitude tends to rise or may plateau as the electrode is inserted.
View Article and Find Full Text PDFPurpose: Balloon dilatation of the Eustachian tube (BDET) is an option for treating chronic obstructive Eustachian tube dysfunction (COETD). In this prospective multicentric study, the main objective was to evaluate the results of BDET in unilateral COETD refractory to medical treatment.
Methods: Adults with unilateral COETD whose Eustachian Tube Score (ETS) was less than 5 despite medical pressure therapy were included.
Cochlear implants are the most common and successful sensory neuroprosthetic devices. However, reimplantation can be required for medical reasons, device failure, or technological upgrading. Resolving the problem driving the intervention and offering stable or better audiological results are the main challenges.
View Article and Find Full Text PDFMiddle ear muscle (MEM) abnormalities have been proposed to be involved in the development of ear-related symptoms such as tinnitus, hyperacusis, ear fullness, dizziness and/or otalgia. This cluster of symptoms have been called the Tonic Tensor Tympani Syndrome (TTTS) because of the supposed involvement of the tensor tympani muscle (TTM). However, the putative link between MEM dysfunction and the symptoms has not been proven yet and the detailed mechanisms (the causal chain) of TTTS are still elusive.
View Article and Find Full Text PDFSound-level coding in the auditory nerve is achieved through the progressive recruitment of auditory nerve fibers (ANFs) that differ in threshold of activation and in the stimulus level at which the spike rate saturates. To investigate the functional state of the ANFs, the electrophysiological tests routinely used in clinics only capture the first action potentials firing in synchrony at the onset of the acoustic stimulation. Assessment of other properties (e.
View Article and Find Full Text PDFIn France 58% of persons with hearing loss still do not wear hearing aids. Pure-tone audiometry is the traditional gold standard in assessment and screening of hearing impairment, but it requires the use of calibrated devices and soundproof booth. The antiphasic digits-in-noise (DIN) test does not require calibrated material and can run on a standard headset or earbuds connected to a smartphone or a computer.
View Article and Find Full Text PDFEur Ann Otorhinolaryngol Head Neck Dis
January 2022
Objectives: This document presents the fundamentals of speech audiometry in noise, general requirements for implementation and criteria for choice among the tests available in French according to the health-professional's needs.
Material And Methods: The recommendations are based on a systematic analysis of the literature carried out by a multidisciplinary group of doctors, audiologists and audioprosthetists from all over France. They are graded A, B, C or expert opinion according to decreasing level of scientific evidence.
Introduction: There remains no standard imaging method that allows computer-assisted surgery of the cochlea in real time. However, recent evidence suggests that high-frequency ultrasound (HFUS) could permit real-time visualization of cochlear architecture. Registration with an imaging modality that suffers neither attenuation nor conical deformation could reveal useful anatomical landmarks to surgeons.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
July 2021
Background And Purpose: Previous studies have demonstrated the usefulness of non-EPI DWI for detection of residual cholesteatoma. However, limited data are available to determine the suitable duration of imaging follow-up after a first MR imaging with normal findings has been obtained. The present study aimed to determine the optimal duration of non-EPI DWI follow-up for residual cholesteatoma.
View Article and Find Full Text PDFIntroduction: Cochlear implantation is a recent approach proposed to treat single-sided deafness (SSD) and asymmetric hearing loss (AHL). Several cohort studies showed its effectiveness on tinnitus and variable results on binaural hearing. The main objective of this study is to assess the outcomes of cochlear implantation and other treatment options in SSD/AHL on quality of life.
View Article and Find Full Text PDFAcquiring surgical experience in the operating room is increasingly difficult. Simulation of temporal bone drilling is therefore essential, and more and more widely used. The aim of this review is to clarify the limitations of classical surgical training, and to describe the different types of simulation available for temporal bone drilling.
View Article and Find Full Text PDFImportance: Recent studies have suggested that olfactory dysfunction and gustatory dysfunction are associated with coronavirus disease 2019 (COVID-19). However, olfaction has been evaluated solely on reported symptoms, after COVID-19 diagnosis, and in both mild and severe COVID-19 cases, but rarely has it been assessed in prospectively unselected populations.
Objective: To evaluate the diagnostic value of a semiobjective olfactory test developed to assess patient-reported chemosensory dysfunction prior to testing for the presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in patients attending a COVID-19 screening facility.
Correlations between inner ear morphology and auditory sensitivity in the same individual are extremely difficult to obtain for stranded cetaceans. Animals in captivity and rehabilitation offer the opportunity to combine several techniques to study the auditory system and cases of hearing impairment in a controlled environment. Morphologic and auditory findings from two beluga whales () in managed care are presented.
View Article and Find Full Text PDFObjectives: To describe the treatment choice in a cohort of subjects with single-sided deafness (SSD) and asymmetric hearing loss (AHL). To assess the reliability of the treatment trials.
Design: In this national, multicentre, prospective study, the choice of subjects was made after two consecutive trials of Contralateral Routing Of the Signal (CROS) hearing aids and a Bone Conduction Device (BCD) on a headband.
Cochlear implantation consists in electrically stimulating the auditory nerve by inserting an electrode array inside the cochlea, a bony structure of the inner ear. In the absence of any visual feedback, the insertion results in many cases of damages of the internal structures. This paper presents a feasibility study on intraoperative imaging and identification of cochlear structures with high-frequency ultrasound (HFUS).
View Article and Find Full Text PDFEur Ann Otorhinolaryngol Head Neck Dis
October 2021
Objectives: Access to diagnosis and treatments for auditory disorders and related pathologies has regressed in France during the COVID-19 pandemic, posing a risk to the patient's chance of recovery. This best practice recommendations guide aims to list the existing technological solutions for the remote examination of a patient with hearing complaint, and to outline their benefits and, where applicable, their limitations.
Methods: The recommendations were developed both from the clinical experience of the medical experts who drafted the guide, and from an extensive review of the literature dealing with clinical practice recommendations for tele-audiology.
J Assoc Res Otolaryngol
February 2020
Cochlear implant (CI) performance varies dramatically between subjects. Although the causes of this variability remain unclear, the electrode-neuron interface is thought to play an important role. Here we evaluate the contribution of two parameters of this interface on the perception of CI listeners: the electrode-to-modiolar wall distance (EMD), estimated from cone-beam computed tomography (CT) scans, and a measure of neural health.
View Article and Find Full Text PDFIntroduction: Current literature does not provide strong evidence that remote programming of hearing aids is effective, despite its increasing use by audiologists. We tested speech perception outcomes, real-ear insertion gain, and changes in self-perceived hearing impairment after face-to-face and remote programming of hearing aids in a randomized multicentre, single-blind crossover study.
Methods: Adult experienced hearing aid users were enrolled during routine follow-up visits to audiology clinics.