Publications by authors named "Veljko Grilj"

Background And Purpose: This study aimed to investigate the radiochemical oxygen depletion (ROD) in vivo by directly measuring oxygen levels in various mouse tissues during ultra-high dose rate (UHDR) irradiation at clinically relevant doses and dose rates.

Materials And Methods: Mice bearing subcutaneous human glioblastoma (U-87 MG) tumors were used for tumor and normal tissue (skin, muscle, brain) measurements. An oxygen-sensitive phosphorescent probe (Oxyphor PtG4) was injected into the tissues, and oxygen levels were monitored using a fiberoptic phosphorometer during UHDR irradiation with a 6 MeV electron linear accelerator (LINAC).

View Article and Find Full Text PDF

. The primary goal of this research is to demonstrate the feasibility of radiation-induced acoustic imaging (RAI) as a volumetric dosimetry tool for ultra-high dose rate FLASH electron radiotherapy (FLASH-RT) in real time. This technology aims to improve patient outcomes by accurate measurements ofdose delivery to target tumor volumes.

View Article and Find Full Text PDF

Purpose: We conducted a multi-institutional dosimetric audit between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3-dimensional (3D) printed mouse phantom.

Methods And Materials: A computed tomography (CT) scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene (∼1.

View Article and Find Full Text PDF

Purpose: Tumor hypoxia is a major cause of treatment resistance, especially to radiation therapy at conventional dose rate (CONV), and we wanted to assess whether hypoxia does alter tumor sensitivity to FLASH.

Methods And Materials: We engrafted several tumor types (glioblastoma [GBM], head and neck cancer, and lung adenocarcinoma) subcutaneously in mice to provide a reliable and rigorous way to modulate oxygen supply via vascular clamping or carbogen breathing. We irradiated tumors using a single 20-Gy fraction at either CONV or FLASH, measured oxygen tension, monitored tumor growth, and sampled tumors for bulk RNAseq and pimonidazole analysis.

View Article and Find Full Text PDF

Purpose: The capability of ultrahigh dose rate FLASH radiation therapy to generate the FLASH effect has opened the possibility to enhance the therapeutic index of radiation therapy. The contribution of the immune response has frequently been hypothesized to account for a certain fraction of the antitumor efficacy and tumor kill of FLASH but has yet to be rigorously evaluated.

Methods And Materials: To investigate the immune response as a potentially important mechanism of the antitumor effect of FLASH, various murine tumor models were grafted either subcutaneously or orthotopically into immunocompetent mice or in moderately and severely immunocompromised mice.

View Article and Find Full Text PDF

We conducted a multi-institutional audit of dosimetric variability between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3D-printed mouse phantom. A CT scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene ($~1.

View Article and Find Full Text PDF

Background: Beam scanning is a useful technique for the treatment of large tumors when the primary beam size is limited, which is the case with radiation beams used in FLASH radiotherapy.

Purpose: To optimize beam scanning as a dose delivery method for FLASH radiotherapy, it is necessary to first understand the effects of beam scanning on the FLASH effect. To do so, biological FLASH experiments need to be done using defined beam parameters with beam scanning and compared to the situation without beam scanning.

View Article and Find Full Text PDF

Long-term potentiation (LTP) was used to gauge the impact of conventional and FLASH dose rates on synaptic transmission. Data collected from the hippocampus and medial prefrontal cortex confirmed significant inhibition of LTP after 10 fractions of 3 Gy (30 Gy total) conventional radiotherapy. Remarkably, 10x3Gy FLASH radiotherapy and unirradiated controls were identical and exhibited normal LTP.

View Article and Find Full Text PDF

Ionizing radiation is known to be DNA damaging and mutagenic, however less is known about which mutational footprints result from exposures of human cells to different types of radiation. We were interested in the mutagenic effects of particle radiation exposures on genomes of various human cell types, in order to gauge the genotoxic risks of galactic cosmic radiation, and of certain types of tumor radiotherapy. To this end, we exposed cultured cell lines from the human blood, breast and lung to fractionated proton and alpha particle (helium nuclei) beams at doses sufficient to considerably affect cell viability.

View Article and Find Full Text PDF

Purpose: This paper presents the capabilities of the Geant4-DNA Monte Carlo toolkit to simulate water radiolysis with scavengers using the step-by-step (SBS) or the independent reaction times (IRT) methods. It features two examples of application areas: (1) computing the escape yield of HO following a Co γ-irradiation and (2) computing the oxygen depletion in water irradiated with 1 MeV electrons.

Methods: To ease the implementation of the chemical stage in Geant4-DNA, we developed a user interface that helps define the chemical reactions and set the concentration of scavengers.

View Article and Find Full Text PDF

Background: Ultrahigh dose-rate radiotherapy (FLASH-RT) affords improvements in the therapeutic index by minimizing normal tissue toxicities without compromising antitumor efficacy compared to conventional dose-rate radiotherapy (CONV-RT). To investigate the translational potential of FLASH-RT to a human pediatric medulloblastoma brain tumor, we used a radiosensitive juvenile mouse model to assess adverse long-term neurological outcomes.

Methods: Cohorts of 3-week-old male and female C57Bl/6 mice exposed to hypofractionated (2 × 10 Gy, FLASH-RT or CONV-RT) whole brain irradiation and unirradiated controls underwent behavioral testing to ascertain cognitive status four months posttreatment.

View Article and Find Full Text PDF

Background And Purpose: We describe a multicenter cross validation of ultra-high dose rate (UHDR) (>= 40 Gy/s) irradiation in order to bring a dosimetric consensus in absorbed dose to water. UHDR refers to dose rates over 100-1000 times those of conventional clinical beams. UHDR irradiations have been a topic of intense investigation as they have been reported to induce the FLASH effect in which normal tissues exhibit reduced toxicity relative to conventional dose rates.

View Article and Find Full Text PDF

The physico-chemical and biological response to conventional and UHDR electron and proton beams was investigated, along with conventional photons. The temporal structure and nature of the beam affected both, with electron beam at ≥1400 Gy/s and proton beam at 0.1 and 1260 Gy/s found to be isoefficient at sparing zebrafish embryos.

View Article and Find Full Text PDF

Purpose: The FLASH effect is characterized by normal tissue sparing without compromising tumor control. Although demonstrated in various preclinical models, safe translation of FLASH-radiotherapy stands to benefit from larger vertebrate animal models. Based on prior results, we designed a randomized phase III trial to investigate the FLASH effect in cat patients with spontaneous tumors.

View Article and Find Full Text PDF

Higher dose rates, a trend for radiotherapy machines, can be beneficial in shortening treatment times for radiosurgery and mitigating the effects of motion. Recently, even higher doses (e.g.

View Article and Find Full Text PDF

Purpose: The Oriatron eRT6 is a linear accelerator (linac) used in FLASH preclinical studies able to reach dose rates ranging from conventional (CONV) up to ultrahigh (UHDR). This work describes the implementation of commercially available beam current transformers (BCTs) as online monitoring tools compatible with CONV and UHDR irradiations for preclinical FLASH studies.

Methods: Two BCTs were used to measure the output of the Oriatron eRT6 linac.

View Article and Find Full Text PDF

Purpose: To implement and validate a beam current transformer as a passive monitoring device on a pulsed electron beam medical linear accelerator (LINAC) for ultra-high dose rate (UHDR) irradiations in the operational range of at least 3 Gy to improve dosimetric procedures currently in use for FLASH radiotherapy (FLASH-RT) studies.

Methods: Two beam current transformers (BCTs) were placed at the exit of a medical LINAC capable of UHDR irradiations. The BCTs were validated as monitoring devices by verifying beam parameters consistency between nominal values and measured values, determining the relationship between the charge measured and the absorbed dose, and checking the short- and long-term stability of the charge-absorbed dose ratio.

View Article and Find Full Text PDF

Purpose: To present the acceptance and the commissioning, to define the reference dose, and to prepare the reference data for a quality assessment (QA) program of an ultra-high dose rate (UHDR) electron device in order to validate it for preclinical animal FLASH radiotherapy (FLASH RT) experiments and for FLASH RT clinical human protocols.

Methods: The Mobetron device was evaluated with electron beams of 9 MeV in conventional (CONV) mode and of 6 and 9 MeV in UHDR mode (nominal energy). The acceptance was performed according to the acceptance protocol of the company.

View Article and Find Full Text PDF

Mass casualty exposure scenarios from an improvised nuclear device are expected to be far more complex than simple photons. Based on the proximity to the explosion and potential shielding, a mixed field of neutrons and photons comprised of up to approximately 30% neutrons of the total dose is anticipated. This presents significant challenges for biodosimetry and for short-term and long-term medical treatment of exposed populations.

View Article and Find Full Text PDF

The consideration of how a given technique affects results of experimental measurements is a must to achieve correct data interpretation. This might be challenging when it comes to measurements on biological systems, where it is unrealistic to have full control (e.g.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effects of mixed neutron and photon radiation on gene expression in human blood, particularly in the context of a potential improvised nuclear device (IND) explosion.
  • It analyzes various combinations of neutron-photon exposures to determine how increasing neutron percentages influence gene responses, revealing that more neutrons lead to higher gene expression levels.
  • Key findings include significant changes in TP53 signaling and immune response pathways, highlighting the distinct biological impacts of neutron exposure compared to pure photon radiation.
View Article and Find Full Text PDF

Heightened threats for nuclear terrorism using improvised nuclear devices (IND) necessitate the development of biodosimetry assays that could rapidly assess thousands of individuals. However, the radiation exposures from an IND may be complex due to mixed fields of neutrons and photons (γ-rays), shielding from buildings, and proximity to the epicenter among others. In this study we utilized lipidomics to analyze serum samples from mice exposed to various percentages of neutrons and X-rays to a total dose of 3 Gy.

View Article and Find Full Text PDF

Background: Radiotherapy outcomes are limited by toxicity in the healthy tissues surrounding the irradiated tumor. Recent pre-clinical studies have shown that irradiations with electrons or photons delivered at so called FLASH dose rates (i.e.

View Article and Find Full Text PDF

An approach based on track-structure calculations has been developed to take account of artefacts occurring during γ-H2AX foci detection in 2D images of samples analyzed through immunocytochemistry. The need of this works stems from the observed saturation in foci yields measured after X-ray doses higher than few grays, hindering an unambiguous quantification of DNA damage and of radiation effectiveness. The proposed modelling approach allows to simulate the observer's point of view for foci scoring, mimicking the selection of a slice Δz of the cell nucleus due to the microscope depth of field, and applying a clustering algorithm to group together damages within a resolution parameter r.

View Article and Find Full Text PDF