Purpose: To validate the use of a split-bolus pancreas CTA protocol for local staging of pancreatic cancer and to evaluate its ability to detect and characterize liver lesions.
Methods: Consecutive patients with pancreatic cancer who underwent split-bolus pancreas CTA between 12/2015 and 12/2016 were included in this IRB-approved HIPAA-compliant retrospective study. Objective evaluation of the abdominal vessels, the pancreas, the liver, and lesions, if present, was performed with attenuation measurements and tumor conspicuity and contrast-to-noise ratio (CNR) calculations.
Objective: The purpose of this article is to evaluate the image quality and added value of split-bolus contrast agent injection combining late arterial and portal venous phases compared with single-bolus contrast agent injection late arterial phase CT enterography.
Materials And Methods: Consecutive patients who underwent CT enterography before and after implementation of a single-bolus CT enterography protocol were included. Attenuation and contrast-to-noise ratio (CNR) were assessed by ROI measurements of the bowel wall and arterial and venous structures.
Purpose: To investigate the feasibility and accuracy of a split-bolus contrast injection CTA (SB-CTA) compared to a single-bolus injection CTA (SI-CTA) protocol of post-EVAR patients.
Materials And Methods: In this IRB-approved study, patients who underwent SB-CTA and SI-CTA after EVAR were evaluated. Attenuation and contrast-to-noise ratio (CNR) of vessels and parenchymal organs were assessed.
Purpose: To assess single energy metal artifact reduction (SEMAR) and spectral energy metal artifact reduction (MARS) algorithms in reducing artifacts generated by different metal implants.
Materials And Method: Phantom was scanned with and without SEMAR (Aquilion One, Toshiba) and MARS (Discovery CT750 HD, GE), with various metal implants. Images were evaluated objectively by measuring standard deviation in regions of interests and subjectively by two independent reviewers grading on a scale of 0 (no artifact) to 4 (severe artifact).
Purpose: To evaluate the value of metal artifact reduction (MAR) post-processing and iodine MD images in fast kV-switching dual-energy computed tomography (DECT) in patients after endovascular aortic repair (EVAR).
Materials And Methods: Twenty-four consecutive EVAR patients (age 76 ± 9 years, 7/24 (29%) with coils, 9/24 (37.5%) with 10 endoleaks) who underwent DECT angiography were included in this HIPAA-compliant, IRB-approved retrospective study.
Purpose: The purpose of the study was to evaluate diagnostic yield and the added value of culture results on the clinical management of patients empirically treated with antibiotics prior to CT-guided drainage.
Methods: This retrospective, HIPAA-compliant, IRB-approved study reviewed records of 300 consecutive patients who underwent CT-guided aspiration or drainage for suspected infected fluid collection while on empiric antibiotics (11/2011 to 9/2013) at a single institution. Patient imaging and clinical characteristics were evaluated by an abdominal imaging fellow and culture results, and patient management were evaluated by an infectious diseases fellow.
Purpose: To investigate incidental pancreatic cysts (IPCs) size discrepancy in a cohort of patients receiving both computed tomography (CT) and magnetic resonance imaging (MRI) and its impact on clinical management based on the 2010 American College of Radiology (ACR) guidelines.
Methods: This was a HIPAA-compliant, retrospective, IRB-approved study. Informed consent was waived.
In our emergency department (ED), patients with flank pain often undergo non-enhanced computed tomography (NECT) to assess for nephroureteral (NU) stone. After immediate image review, decision is made regarding need for subsequent contrast-enhanced CT (CECT) to help assess for other causes of pain. This study aimed to review the experience of a single institution with this protocol and to assess the utility of CECT.
View Article and Find Full Text PDFObjective: To develop a simplified method to quantify liver fat using computed tomography (CT) fat % index (CTFPI) compared to liver spleen method (CTL/S, CTL-S).
Methods: Noncontrast CT of the liver was performed in 89 patients (overweight, obese, severely obese) to quantify fat, using the following: CTFPI=[(65-patient HU)/65]×100, normal live r=65 HU.
Results: There was a strong linear correlation between CTFPI and the standard method of assessing liver fat using CTL/S (r=-0.
Purpose: To assess tumor conspicuity and radiation dose with a new multidetector computed tomography (CT) protocol for pancreatic imaging that combines spectral CT and split-bolus injection.
Materials And Methods: This study was approved by the institutional review board and compliant with HIPAA. The requirement for informed consent was waived.
Purpose: To evaluate spectral computed tomography (CT) with metal artifacts reduction software (MARS) for reduction of metal artifacts associated with gold fiducial seeds.
Materials And Methods: Thirteen consecutive patients with 37 fiducial seeds implanted for radiation therapy of abdominal lesions were included in this HIPAA-compliant, institutional review board-approved prospective study. Six patients were women (46%) and seven were men (54%).
Objective: We compared phantom organ doses delivered to breast, lung, and pelvis by five protocols using current dose reduction methods for routine chest CT and pulmonary CT angiography.
Materials And Methods: We measured the radiation dose to an anthropomorphic phantom using 64-MDCT with metal oxide semiconductor field effect transistor (MOSFET) detectors in the breast (skin and parenchyma), the lungs, and the pelvis (upper and lower). We compared the following five protocols: protocol 1, 120 kVp, automatic dose modulation, 120-320 mA; protocol 2, 120 kVp, automatic dose modulation, 60-200 mA; protocol 3, 100 kVp and fixed dose of 200 mA; protocol 4, 120 kVp, automatic dose modulation, 200-394 mA; and protocol 5, 80 kVp and fixed dose of 120 mA.
Objective: The purpose of this article is to evaluate the incidence of contrast-induced nephropathy (CIN) and the effects of associated risk factors in patients with multiple myeloma undergoing contrast-enhanced CT (CECT) with IV administration of nonionic iodinated contrast agent.
Materials And Methods: This retrospective review of medical records identified patients with a diagnosis of myeloma who underwent a CECT examination of the chest, abdomen, or pelvis between January 1, 2005, and December 1, 2008. Analysis for CIN, as defined by an increase in creatinine level after the CECT examination of 25% or more, or of 0.
Objective: The purpose of this article is to estimate the absorbed radiation dose in radiosensitive organs during coronary MDCT angiography using 320-MDCT and to determine the effects of tube voltage variation and heart rate (HR) control on absorbed radiation dose.
Materials And Methods: Semiconductor field effect transistor detectors were used to measure absorbed radiation doses for the thyroid, midbreast, breast, and midlung in an anthropomorphic phantom at 100, 120, and 135 kVp at two different HRs of 60 and 75 beats per minute (bpm) with a scan field of view of 320 mm, 400 mA, 320 × 0.5 mm detectors, and 160 mm collimator width (160 mm range).
Background And Aims: The Raptopoulos computed tomography (CT) grading system of pancreaticobiliary cancers was conceived to predict resectability based on tumour involvement of critical vasculature. The aim of the present study was to investigate the relationship between CT grade, resectability, margin status and survival after pancreatic resection.
Methods: Patients with presumed pancreaticobiliary malignancy and a pancreas protocol computed tomography angiogram (CTA) who underwent attempted curative resection from October 2001 and August 2008 were identified.
Conventional radiologic and endoscopic evaluations of the small bowel are often limited by the length, caliber, and motility of the small bowel loops. The development of new multidetector-row CT scanners, with faster scan times and isotropic spatial resolution, allows high-resolution multiphasic and multiplanar assessment of the bowel, bowel wall, and lumen. CT Enterography (CTE) is a variant of routine abdominal scanning, geared toward more sustained bowel filling with oral contrast material, and the use of multiplanar images, that can enhance gastrointestinal (GI) tract imaging.
View Article and Find Full Text PDFObjective: The objective of our study was to test a dose reduction protocol that uses combined vascular-excretory phase scanning achieved by split IV contrast injection and compare it with conventional multiphase MDCT angiography (MDCTA) in evaluating potential renal donors.
Materials And Methods: This study is a review of MDCTA examinations of 54 potential renal donors scanned on 16- and 64-MDCT. The IV bolus was split: 50 mL was administered 3 minutes before scanning and a second injection of 70-100 mL was administered at a rate of 4-6 mL/s, with CT angiography started by bolus tracking.
Purpose: The aim of this study was to quantify the effect of a reduced-dose pulmonary computed tomographic (CT) angiography protocol on radiation dose and image quality in pregnant patients as compared with a standard protocol.
Materials And Methods: Twenty-six pregnant women with suspected pulmonary embolism underwent reduced-dose CT angiography (200 mA and 100 kV, from the aortic arch to the diaphragm). The matched control group standard protocol was 400 mA, 120 kilovolt (peak), and the entire thorax.
Objective: This review focuses on the role of CT and MRI in the diagnosis, follow-up, and surgical planning of aortic aneurysms and acute aortic syndromes, including aortic dissection, intramural hematoma, and penetrating aortic ulcer. It also provides a systematic approach to the definition, causes, natural history, and imaging principles of these diseases.
Conclusion: An understanding of the pathophysiology, natural history, and imaging features is the key to successful diagnosis and appropriate management of patients with these aortic diseases.
Purpose: To assess the value of liver parenchyma enhancement tracking for liver multidetector computed tomography (CT) in patients with potential hypoattenuating liver metastases.
Materials And Methods: Institutional review board approved this Health Insurance Portability and Accountability Act-compliant study. We reviewed the chest-abdomen-pelvis CTs of 120 consecutive patients scanned on 16-/64-row multidetector CT after receiving 52 g I in 50 seconds.
Purpose: To evaluate the effects of total scanning time (TST), interscan delay (ISD), inclusion of image at peak vascular enhancement (IPVE), and selection of the input function vessel on the accuracy of tumor blood flow (BF) calculation with computed tomography (CT) in an animal model.
Materials And Methods: All animal protocols and experiments were approved by the institutional animal care and use committee prior to study initiation. After injection of 0.
Purpose: To evaluate routine use of CT Enterography (CTE) in patients presenting with non-traumatic acute abdominal pain with respect to patient tolerance, imaging of intestinal detail along with conventional abdominal evaluation.
Materials And Methods: Modified CTE was performed in 165 consecutive patients with acute abdominal pain: ingestion, as tolerated, of 900-1200 ml of 2% barium suspension + 5 ml of Gastrografin over 45 min; 150 ml of iv contrast given in two boluses (50 and 100 ml) 3 min apart (split bolus injection protocol). Axial, coronal and sagittal reformats were reviewed by two radiologists and graded on a 5-point scale (5 best) in regard to GI tract luminal opacification and distension and abdominal organ and vascular enhancement.
Objective: The objective of our study was to determine whether perfusion CT can be used to detect early changes in therapeutic response to antiangiogenic therapy in an animal tumor model.
Materials And Methods: Twenty-five rats implanted with R3230 mammary adenocarcinoma (diameter, 1.2-2.