Publications by authors named "Vasilis Kilintzis"

The objective of the presented cross-sectional-evaluation-screening study is the clinical evaluation of high-risk(hr)HPVE7-protein detection as a triage method to colposcopy for hrHPV-positive women, using a newly developed sandwich-ELISA-assay. Between 2013-2015, 2424 women, 30-60 years old, were recruited at the Hippokratio Hospital, Thessaloniki/Greece and the Im Mare Klinikum, Kiel/Germany, and provided a cervical sample used for Liquid Based Cytology, HPV DNA genotyping, and E7 detection using five different E7-assays: "recomWell HPV16/18/45KJhigh", "recomWell HPV16/18/45KJlow", "recomWell HPV39/51/56/59", "recomWell HPV16/31/33/35/52/58" and "recomWell HPVHRscreen" (for 16,18,31,33,35,39,45,51,52,56,58,59 E7), corresponding to different combinations of hrHPVE7-proteins. Among 1473 women with eligible samples, those positive for cytology (ASCUS+ 7.

View Article and Find Full Text PDF

Purpose: The purpose of the presented PIPAVIR (persistent infections with human papillomaviruses; http://www.pipavir.com ) subanalysis is to assess the performance of high-risk (hr) HPV-DNA genotyping as a method of primary cervical cancer screening and triage of HPV positive women to colposcopy compared to liquid-based cytology (LBC) in an urban female population.

View Article and Find Full Text PDF

We propose WELCOME, an innovative integrated care platform using wearable sensors and smart cloud computing for Chronic Obstructive Pulmonary Disease (COPD) patients with co-morbidities. WELCOME aims to bring about a change in the reactive nature of the management of chronic diseases and its comorbidities, in particular through the development of a patient centred and proactive approach to COPD management. The aim of WELCOME is to support healthcare services to give early detection of complications (potentially reducing hospitalisations) and the prevention and mitigation of comorbidities (Heart Failure, Diabetes, Anxiety and Depression).

View Article and Find Full Text PDF

Purpose: To evaluate the inter-examiner reproducibility of Ocular Response Analyzer (ORA) parameters in healthy subjects using the waveform score (WS) for quality control of acquisition.

Patients And Methods: Fifteen healthy subjects had their intraocular pressure (IOP) measured with ORA by 2 masked examiners. An acquisition protocol that aimed at obtaining 4 reliable measurements in each eye with WS≥6 and with as few repeated measurements as possible was employed, whereas a maximum of 8 measurements per eye was allowed.

View Article and Find Full Text PDF