Objective: To evaluate whether the ZyMōt™ Multi 850 μl sperm separation device (SSD) effectively recovers motile spermatozoa from cryopreserved ejaculates and compare its effect on key embryology outcomes including fertilization, cleavage stage, and total and top-quality blastocyst formation rates to the traditional Density Gradient Centrifugation (DGC) method.
Methods: In this prospective, single-center, controlled study, we used fresh sibling donor oocytes and non-donor cryopreserved ejaculates. In total, 150 couples participated in this study.