Publications by authors named "Varsha Siju"

Nascent observations about the influence of kinetic instabilities on electron cyclotron emission (ECE) from runaway electrons (REs) have been detected and explored at the Aditya-Upgrade (Aditya-U) tokamak. The developed broadband ECE radiometer system offers wideband measurements by integrating several radio frequency units with a fixed intermediate frequency receiver with multiple channels, which is a novel approach to meet the needs of the localized measurements at various toroidal fields and extend the system dynamic range. The low density (n ≤ 1 × 10 m) plasma discharges at Aditya-U are consistently accompanied by a 20%-40% increase in the ECE radiometer signal amplitude within 100 µs and sporadic step-like modulations.

View Article and Find Full Text PDF

This paper reports the design, development and characterization of a broadband, polarization insensitive metasurface absorber in planar, cylindrically bent and 90° dihedral surface geometry. Four metallic patches loaded with eight lumped resistors are used, which has been optimized numerically using CST MICROWAVE STUDIO, as a unit cell of developed metasurface absorber, to achieve 20 dB reflection reduction for 51.21% fractional bandwidth (13.

View Article and Find Full Text PDF

This paper describes the characterisation of a negative feedback type of automatic gain control (AGC) circuit that will be an integral part of the heterodyne radiometer system operating at a frequency range of 75-86 GHz at SST-1 tokamak. The developed AGC circuit is a combination of variable gain amplifier and log amplifier which provides both gain and attenuation typically up to 15 dB and 45 dB, respectively, at a fixed set point voltage and it has been explored for the first time in tokamak radiometry application. The other important characteristics are that it exhibits a very fast response time of 390 ns to understand the fast dynamics of electron cyclotron emission and can operate at very wide input RF power dynamic range of around 60 dB that ensures signal level within the dynamic range of the detection system.

View Article and Find Full Text PDF

An 8-channel E-band heterodyne radiometer system (74-86 GHz) is designed, characterized, and calibrated to measure the radial electron temperature profile by measuring Electron Cyclotron Emission spectrum at SST-1 Tokamak. The developed radiometer has a noise equivalent temperature of 1 eV and sensitivity of 5 × 10(9) V/W. In order to precisely measure the absolute value of electron temperature, a calibration measurement of the radiometer system is performed using hot-cold Dicke switch method, which confirms the system linearity.

View Article and Find Full Text PDF