Objective: To compare the predictive accuracy of prostate-specific antigen (PSA) density vs PSA across different PSA ranges and by prior biopsy status in a prospective cohort undergoing prostate biopsy.
Materials And Methods: Men from a prospective trial underwent an extended template biopsy to evaluate for prostate cancer at 26 sites throughout the United States. The area under the receiver operating curve assessed the predictive accuracy of PSA density vs PSA across 3 PSA ranges (<4 ng/mL, 4-10 ng/mL, >10 ng/mL).
Background: Silicone injection can cause numerous posttreatment complications-including debilitating pain, cellulitis, abscesses, overlying skin compromise, and siliconomas distorting overlying tissues-that can be difficult to manage.
Objectives: The authors evaluate liposuction as a treatment for patients experiencing complications from silicone injections to the gluteal region, to both preserve aesthetic appearance and minimize further risk of complication from these procedures.
Methods: Eight patients (7 women and 1 man) who presented consecutively to us between 2010 and 2013 with complications from silicone injections to their gluteal region were enrolled in this study.