Publications by authors named "Vandekerckhove Y"

Background: The implantable cardioverter-defibrillator (ICD) remains the cornerstone in the prevention of sudden cardiac death. Cost-effectiveness depends on survival after implantation. In Belgium there are unexplained major differences in 3-year mortality after ICD implantation.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the outcomes of implantable cardiac defibrillator (ICD) procedures in patients over 80 years old in Belgium, analyzing data from 704 patients implanted between 2010 and 2019.
  • Results indicated that 35% of these patients died during a mean follow-up of 3.1 years, with 11% dying within the first year.
  • Key factors influencing mortality included age, a history of cancer, type of prevention (primary vs. secondary), and the health of the heart (measured by left ventricular ejection fraction).
View Article and Find Full Text PDF

Background: The impact of sex on ICD implantation practice and survival remain a topic of controversy. To assess sex-specific differences in ICD implantation practice we compared clinical characteristics and survival in women and men.

Methods: From a nationwide registry, all new ICD implantations performed between 01/02/2010 and 31/01/2019 in Belgian patients were analyzed retrospectively.

View Article and Find Full Text PDF

Objectives: Directed graph-mapping (DGM) is a novel operator-independent automatic tool that can be applied to the identification of the atrial tachycardia (AT) mechanism. In the present study, for the first time, DGM was applied in complex AT cases, and diagnostic accuracy was evaluated.

Background: Catheter ablation of ATs still represents a challenge, as the identification of the correct mechanism can be difficult.

View Article and Find Full Text PDF

Aims: Catheter ablation of paroxysmal atrial fibrillation (AF) reduces AF recurrence, AF burden, and improves quality of life. Data on clinical and procedural predictors of arrhythmia recurrence are scarce and are flawed by the high rate of pulmonary vein reconnection evidenced during repeat procedures after pulmonary vein isolation (PVI). In this study, we identified clinical and procedural predictors for AF recurrence 1 year after CLOSE-guided PVI, as this strategy has been associated with an increased PVI durability.

View Article and Find Full Text PDF

Background: CLOSE-guided atrial fibrillation (AF) ablation is based on contiguous (intertag distance ≤6 mm), optimized (Ablation Index >550 anteriorly and >400 posteriorly) point-by-point radiofrequency lesions. The optimal radiofrequency power remains unknown.

Methods: The POWER-AF study is a prospective, randomized controlled monocentric study including patients with paroxysmal AF, planned for first CLOSE-guided pulmonary vein isolation using a contact force radiofrequency catheter (Thermocool SmartTouch, Biosense Webster, Inc, Irvine, CA).

View Article and Find Full Text PDF

Objective: Left atrial (LA) thrombus is routinely excluded by transoesophageal echocardiography (TOE) before cardioversion for non-valvular atrial fibrillation (AF). In the D-dimer blood concentrations to exclude LA thrombus in patients with AF study, two D-dimer cut-offs were compared to exclude LA thrombus prior to cardioversion. One was fixed to 500 ng/mL (DD500), based on clinical practice where such values are commonly accepted to exclude a thrombus.

View Article and Find Full Text PDF

Aims: The relation between atrial tachyarrhythmia (ATA) burden in paroxysmal atrial fibrillation (AF), atrial remodelling, and efficacy of catheter ablation (CA) is unknown. We investigated whether high vs. low-burden paroxysmal AF patients have distinct clinical characteristics or electro-mechanical properties of the left atrium (LA) and whether burden impacts outcome of CA.

View Article and Find Full Text PDF

During the coronavirus disease (COVID-19) pandemic, cardiologists have attempted to minimize risks to their patients by using telehealth to provide continuing care. Rapid implementation of video consultations in outpatient clinics for patients with heart disease can be challenging. We employed a design thinking tool called a customer journey to explore challenges and opportunities when using video communication software in the cardiology department of a regional hospital.

View Article and Find Full Text PDF

Recent MitraClip heart failure (HF) trials suggest that baseline left ventricular (LV) remodeling may be critical for patient selection. We, therefore, investigated whether baseline LV remodeling affects safety, efficacy, and clinical outcomes in HF patients with symptomatic secondary mitral regurgitation (MR) undergoing percutaneous mitral valve repair using MitraClip. LV remodeling was assessed by LV end-systolic dimension index (LVESDi) on transthoracic baseline echocardiography.

View Article and Find Full Text PDF

Aims: "CLOSE"-guided pulmonary vein isolation (PVI) is based on contiguous (≤6 mm) and optimized radiofrequency (RF) ablation lesions (ablation index [AI] ≥ 400 posteriorly and ≥ 550 anteriorly]. However, the optimal RF power to reach the desired AI is unknown. Therefore we evaluated the efficiency of an ablation strategy using higher power (40 W) during a first "CLOSE"-guided PVI.

View Article and Find Full Text PDF
Article Synopsis
  • The ESC congress in September 2019 in Paris introduced new guidelines for managing cardiovascular diseases, now available online.
  • These guidelines cover chronic coronary syndromes, acute pulmonary embolism, supraventricular tachycardia, and dyslipidemias, summarizing key recommendations and changes.
  • The document aims to raise awareness of the new guidelines and encourage healthcare professionals to apply them in everyday clinical settings.
View Article and Find Full Text PDF

Background: Few studies evaluated the impact of catheter ablation (CA) on atrial tachyarrhythmia (ATA) burden in paroxysmal atrial fibrillation (AF).

Objective: In the prospective, patient-controlled CLOSE to CURE study, we determined the longer-term impact of optimized CA on ATA burden by using an insertable cardiac monitor (ICM).

Methods: A total of 105 patients with paroxysmal AF were implanted with an ICM 65 (interquartile range [IQR] 61-78) days before CA.

View Article and Find Full Text PDF

Introduction: Recent studies have characterized drivers in persistent atrial fibrillation using automated algorithm detection with panoramic endocardial mapping by means of basket catheters. We aimed to identify repetitive atrial activation patterns (RAAPs) during ongoing atrial fibrillation (AF) based upon automated annotation of unipolar electrograms (EGMs) recorded with a high-density regional endocardial contact mapping catheter.

Methods: In 14 persistent AF patients, high-resolution EGMs were recorded for 30 seconds at sequential PentaRay (Biosense Inc) positions covering the entire biatrial surface.

View Article and Find Full Text PDF

Background: Identification of atrial tachycardia (AT) mechanism remains challenging.

Objective: We sought to investigate the added value of entrainment maneuvers (EM) when using new high-density activation mapping (HDAM) technologies for the identification of complex left ATs.

Methods: Thirty-six consecutive complex ATs occurring after ablation of persistent atrial fibrillation were prospectively analyzed.

View Article and Find Full Text PDF

This subanalysis of the Euro-CRT survey II specifically focus on Belgian practice for CRT implantation. It explores Belgian adherence with the guidelines but also benchmark CRT practice in Belgium against the other European countries. Overall, Belgian management of CRT implantation is performed with great agreement with guidelines.

View Article and Find Full Text PDF

Background: Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We aimed to formally assess the proof-of-concept and accuracy of self-detection of acute coronary artery occlusion by patients during daily life situations and during the very early stages of acute coronary artery occlusion.

View Article and Find Full Text PDF

Aims: We sought to evaluate the efficacy and the safety of a simple technique for stabilizing the ablation catheter during anterior pulmonary vein (PV) encirclement in patients ablated for paroxysmal atrial fibrillation. This consisted of bending the ablation catheter in the left atrium, creating a loop that was cautiously advanced together with the long sheath at the ostium and then within the left superior PV. The curve was then progressively released to reach a stable contact with the anterior part of the left PVs.

View Article and Find Full Text PDF

Aims: Overall, 40% of patients with atrial fibrillation are asymptomatic. The usefulness and cost-effectiveness of atrial fibrillation screening programmes are debated. We evaluated whether an atrial fibrillation screening programme with a handheld electrocardiogram (ECG) machine in a population-wide cohort has a high screening yield and is cost-effective.

View Article and Find Full Text PDF

Objectives: This study sought to determine the prevalence of patients with 4 isolated veins at repeat ablation after "CLOSE" -guided pulmonary vein isolation (PVI), a strategy based on delivery of contiguous and optimized radiofrequency lesions.

Background: The likelihood of finding 4 isolated veins at a repeat ablation for atrial fibrillation (AF) recurrence after a first PVI is low.

Methods: Patients undergoing repeat ablation for AF recurrence after first CLOSE-guided PVI were included.

View Article and Find Full Text PDF

Background: The incidence of endoscopically detected esophageal lesions after pulmonary vein isolation (PVI) is as high as 18%. Intraesophageal temperature rise (ITR) during ablation is a predictor of esophageal injury.

Objective: The purpose of this study was to describe an ablation strategy aiming to enclose the pulmonary veins with contiguous, stable, and optimized radiofrequency applications (referred to as CLOSE-PVI).

View Article and Find Full Text PDF

Background: There are anecdotal reports of sudden death despite a functional implantable cardioverter defibrillator (ICD). We sought to describe scenarios leading to fatal or near-fatal outcome due to inappropriately inhibited ICD therapy in devices programmed with single-chamber detection criteria.

Methods: Programmed settings, episode lists, and intracardiac electrograms from 24 patients with a life-threatening event (n = 12) or fatal outcome (n = 12) related to failed ventricular arrhythmia detection were used to clarify the underlying scenario.

View Article and Find Full Text PDF