Purpose: In case of a mass-casualty radiological event, there would be a need for networking to overcome surge limitations and to quickly obtain homogeneous results (reported aberration frequencies or estimated doses) among biodosimetry laboratories. These results must be consistent within such network. Inter-laboratory comparisons (ILCs) are widely accepted to achieve this homogeneity.
View Article and Find Full Text PDFMutat Res Genet Toxicol Environ Mutagen
March 2021
Five occupational workers in an industrial sterilization unit at Stamboliyski in Bulgaria were accidentally exposed to a very high specific activity of Cobalt-60 source on June 14, 2011. Initial cytogenetic analysis performed on days 2 and 7 after radiation exposure revealed the whole body absorbed radiation doses of 5.32 Gy for patient 1, 3.
View Article and Find Full Text PDFPurpose: Dose assessment intercomparisons within the RENEB network were performed for triage biodosimetry analyzing G-lymphocyte PCC for harmonization, standardization and optimization of the PCC assay.
Materials And Methods: Comparative analysis among different partners for dose assessment included shipment of PCC-slides and captured images to construct dose-response curves for up to 6 Gy γ-rays. Accident simulation exercises were performed to assess the suitability of the PCC assay by detecting speed of analysis and minimum number of cells required for categorization of potentially exposed individuals.
Purpose: Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network.
Materials And Methods: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants.
Purpose: In the frame of the QA program of RENEB, an inter-laboratory comparison (ILC) of calibration sources used in biological dosimetry was achieved to investigate the influence of calibration practices and protocols on the results of the dose estimation performance as a first step to harmonization and standardization of dosimetry and irradiation practices in the European biological dosimetry network.
Materials And Methods: Delivered doses by irradiation facilities used by RENEB partners were determined with EPR/alanine dosimetry system. Dosimeters were irradiated in the same conditions as blood samples.
Purpose: A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios.
Results: The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices.
Purpose: In the framework of the 'Realizing the European Network of Biodosimetry' (RENEB) project, two intercomparison exercises were conducted to assess the suitability of an optimized version of the cytokinesis-block micronucleus assay, and to evaluate the capacity of a large laboratory network performing biodosimetry for radiation emergency triages. Twelve European institutions participated in the first exercise, and four non-RENEB labs were added in the second one.
Materials And Methods: Irradiated blood samples were shipped to participating labs, whose task was to culture these samples and provide a blind dose estimate.
Int J Radiat Biol
January 2017
Purpose: The RENEB accident exercise was carried out in order to train the RENEB participants in coordinating and managing potentially large data sets that would be generated in case of a major radiological event.
Materials And Methods: Each participant was offered the possibility to activate the network by sending an alerting email about a simulated radiation emergency. The same participant had to collect, compile and report capacity, triage categorization and exposure scenario results obtained from all other participants.
Purpose: To identify and assess, among the participants in the RENEB (Realizing the European Network of Biodosimetry) project, the emergency preparedness, response capabilities and resources that can be deployed in the event of a radiological or nuclear accident/incident affecting a large number of individuals. These capabilities include available biodosimetry techniques, infrastructure, human resources (existing trained staff), financial and organizational resources (including the role of national contact points and their articulation with other stakeholders in emergency response) as well as robust quality control/assurance systems.
Materials And Methods: A survey was prepared and sent to the RENEB partners in order to acquire information about the existing, operational techniques and infrastructure in the laboratories of the different RENEB countries and to assess the capacity of response in the event of radiological or nuclear accident involving mass casualties.
Purpose: To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners.
Materials And Methods: Two sets of 50 high resolution images were uploaded onto the RENEB website. One set included metaphases after a moderate exposure (1.
Purpose: RENEB, 'Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,' is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation.
View Article and Find Full Text PDFMultiple sclerosis is a clinically heterogeneous autoimmune disease leading to severe neurological disability. Although during the last years many disease-modifying agents as treatment options for multiple sclerosis have been made available, their mechanisms of action are still not fully determined. In the present study radiosensitivity in lymphocytes of patients with relapsing-remitting multiple sclerosis, secondary progressive multiple sclerosis and healthy controls was investigated.
View Article and Find Full Text PDFThe aim of this study was to evaluate the genotoxic effects of ionizing radiation in vivo in exposed Bulgarian nuclear power plant workers by using classical cytogenetic and molecular cytogenetic analyses of peripheral lymphocytes. Chromosome analysis using fluorescence in situ hybrydization (FISH) and Giemsa techniques was undertaken on 63 workers and 45 administrative staff controls from the Bulgarian Nuclear Power Plant. Using the Giemsa method, the frequencies of cells studied with chromosome aberrations, dicentrics plus rings and chromosome fragments in the radiation workers were significantly higher compared with the control group (P = 0.
View Article and Find Full Text PDFThe human buccal micronucleus cytome assay (BMCyt) is one of the most widely used techniques to measure genetic damage in human population studies. Reducing protocol variability, assessing the role of confounders, and estimating a range of reference values are research priorities that will be addressed by the HUMN(XL) collaborative study. The HUMN(XL) project evaluates the impact of host factors, occupation, life-style, disease status, and protocol features on the occurrence of MN in exfoliated buccal cells.
View Article and Find Full Text PDFBackground: Pelvic organs morbidity after irradiation of cancer patients remains a major problem although new technologies have been developed and implemented. A relatively simple and suitable method for routine clinical practice is needed for preliminary assessment of normal tissue intrinsic radiosensitivity. The micronucleus test (MNT) determines the frequency of the radiation induced micronuclei (MN) in peripheral blood lymphocytes, which could serve as an indicator of intrinsic cell radiosensitivity.
View Article and Find Full Text PDFThis paper details the construction of a 137Cs gamma calibration curve that has been established for dicentric assay and the testing and validation of the curve through biological dosimetry in three situations of suspected workplace overexposure that arose accidentally or through negligence or lack of appropriate safety measures. The three situations were: (1) suspected 137Cs contamination in a factory air supply; (2) suspected exposure to an industrial 192Ir source; and (3) accidental exposure of construction workers to radiation from a 60Co radiotherapy source in a hospital medical physics department. From a total of 24 potentially-exposed subjects, only one worker was found to have a statistically significant dose (0.
View Article and Find Full Text PDFCytokinesis-blocked micronucleus assay (MNT) was applied in the peripheral blood lymphocytes of patients undergoing radioiodine-131 ((131)I) therapy for differentiated thyroid carcinoma (DTC) after thyroidectomy to assess the genotoxic risk of this therapy. The amount of administered (131)I activity varied from 3,330 to 4,030 MBq. Blood samples were taken immediately before (131)I administration and one month later, along with routine blood tests.
View Article and Find Full Text PDFNuclear power plant workers are exposed to ionizing radiation at relatively low doses and for prolonged periods of time. To investigate the extent of genetic damage in these workers, a group of 133 nuclear power plant workers and 39 healthy controls were compared using the cytokinesis-block micronucleus assay. The frequency of micronuclei was significantly increased in peripheral lymphocytes of nuclear power plant workers (20.
View Article and Find Full Text PDFOne of the objectives of the HUman MicroNucleus (HUMN) project is to identify the methodological variables that have an important impact on micronucleus (MN) or micronucleated (MNed) cell frequencies measured in human lymphocytes using the cytokinesis-block micronucleus assay. In a previous study we had shown that the scoring criteria used were likely to be an important variable. To determine the extent of residual variation when laboratories scored cells from the same cultures using the same set of standard scoring criteria, an inter-laboratory slide-scoring exercise was performed among 34 laboratories from 21 countries with a total of 51 slide scorers involved.
View Article and Find Full Text PDFThe aim of the present study was to evaluate the genotoxic effects of hexavalent chromium (Cr(VI)) in vivo in exposed Bulgarian chromium platers by using classical cytogenetic and molecular cytogenetic analyses of peripheral lymphocytes and exfoliated buccal cells. No significant difference was observed between the exposed workers and the controls with regard to the frequency of cells with chromosome aberrations (CAs) using conventional Giemsa staining and in the frequency of sister chromatid exchanges (SCEs). However, there was a significant increase in the number of cells with micronuclei (MN) in peripheral lymphocytes from chromium exposed workers as compared to the controls.
View Article and Find Full Text PDF