Publications by authors named "Valentina Moioli"

Objectives: Cellular analysis of body fluids (BFs) can assist clinicians for the diagnosis of many medical conditions. The aim of this work is the evaluation of the analytical performance of the UF-5000 body fluid mode (UF-BF) analyzer compared to the gold standard method (optical microscopy, OM) and to XN-1000 (XN-BF), another analyzer produced by the same manufacturer (Sysmex) and with a similar technology for BF analysis.

Methods: One hundred BF samples collected in KEDTA tubes were analyzed by UF-BF, XN-BF and OM.

View Article and Find Full Text PDF

Objective: Biochemical and cytological pericardial fluid (PF) analysis is essentially based on the knowledge of pleural fluid composition. The aim of the present study is to identify reference intervals (RIs) for PF according to state-of-art methodological standards.

Methods: We prospectively collected and analysed the PF and venous blood of consecutive subjects undergoing elective open-heart surgery from July 2017 to October 2018.

View Article and Find Full Text PDF

Background In a generalist laboratory, the integration of the data obtained from hematology analyzers (HAs) with those from multiparametric flow cytometry (FMC) could increase the specificity and sensitivity of first level screening to identify the pathological samples. The aim of this study was to perform a preliminary evaluation of a new simple hybrid method (HM). The method was obtained by integration between HAs reagents into FCM, with a basic monoclonal antibodies panel for the leukocytes differential count.

View Article and Find Full Text PDF

Aims: Limited information is available on number and type of cells present in the pericardial fluid (PF). Current evidence and has been garnered with inaccurate application of guidelines for analysis of body fluids. This study was aimed at investigating the performance of automate cytometric analysis of PF in adult subjects.

View Article and Find Full Text PDF

Introduction: Cellular analysis in body fluids (BFs) provides important diagnostic information in various pathological settings. This study was hence aimed at comparing automated cell count obtained with Mindray BC-6800 (BC-BF) vs Sysmex XN-series (XN-BF) and evaluating other quantitative and qualitative information provided by these analyzers in ascitic (AF), pleural (PF), synovial (SF), and cerebrospinal (CSF) fluids.

Methods: Three hundred and fifty-one samples (99 AFs, 45 PFs, 75 SFs, and 132 CSFs) were analyzed in parallel with BC-BF, XN-BF, and optical microscopy (OM).

View Article and Find Full Text PDF

Background: The cell population data (CPD) measured by Sysmex XN-9000 can be used for screening many hematological and non-hematological disorders. Since little information is available on harmonization of CPD among different instrumentation and clinical laboratories, this study aimed at assessing the current degree of CPD harmonization between separate Sysmex XN modules allocated to the same laboratory.

Methods: A total number of 78291 data were used for verification of within-run imprecision, analyzers harmonization, reference ranges and assessment of blood sample stability of CPD parameters, including results of daily quality control testing and those generated in samples collected from blood donors and healthy volunteers.

View Article and Find Full Text PDF