Publications by authors named "V Trehan"

Over the past decade, percutaneous left ventricular assist devices (pLVAD), such as the Impella microaxial flow pump (Abiomed), have been increasingly used to provide haemodynamic support during complex and high-risk revascularisation procedures to reduce the risk of intraprocedural haemodynamic compromise and to facilitate complete and optimal revascularisation. A global consensus on patient selection for the use of pLVADs, however, is currently lacking. Access to these devices is different across the world, thus, individual health care environments need to create and refine patient selection paradigms to optimise the use of these devices.

View Article and Find Full Text PDF

A 38-year-old female was found to have severe mitral stenosis, severe pulmonary arterial hypertension with moderate tricuspid regurgitation, dilated right atrium, persistent left superior vena cava, and hugely dilated coronary sinus. The scheduled balloon mitral valvotomy via trans-femoral approach was abandoned after the venogram revealed the presence of left-sided inferior vena cava with hemi-azygos continuation draining into coronary sinus via left-sided superior vena cava. Balloon mitral valvotomy was attempted from the right trans-jugular route, but we were unable to puncture the inter-atrial septum due to the hugely dilated coronary sinus and right atrium.

View Article and Find Full Text PDF

Despite having an incidence of 0.5 to 2%, stent thrombosis has an in-hospital mortality of 15% and myocardial infarction (MI) incidence of 67%. Even with the usage of thrombus aspiration devices and microvasculature vasodilators such as nitroprusside, verapamil, adenosine, and Gp2b/3a inhibitors, the angiographic result of percutaneous coronary intervention of coronary stent thrombosis remains frequently suboptimal due to distal embolization and subsequent slow flow.

View Article and Find Full Text PDF

Background: Riata implantable cardioverter-defibrillator (ICD) leads are prone to a unique type of mechanical lead failure causing conductor externalization (CE) which may be complicated by a delayed-onset electrical lead failure (ELF).

Case Summary: A 60-year-old male with symptomatic, severe ischaemic cardiomyopathy, and atrial fibrillation following a prior anterior wall myocardial infarction received a dual-chamber ICD with 7F-RiataST ventricular lead as a primary prevention strategy against sudden cardiac death in 2008. In 2017, a pulse generator replacement was performed for elective replacement indicator status.

View Article and Find Full Text PDF

Introduction Atrial fibrillation and mitral stenosis, especially in combination, increase the risk of left atrial thrombus formation and systemic embolization. However, whether severe mitral regurgitation (MR) improves systemic hypercoagulable state in these patients is unclear. remains unclear.

View Article and Find Full Text PDF