The femoral artery (FA) is the largest vessel in the hindlimb circulation and its proper tone regulation ensures adequate blood supply to muscle tissue. We investigated whether an alanine mutation of the targeting subunit of myosin-light-chain-phosphatase (MLCP), MYPT1, at threonine 696 (MYPT1-T696A/+), decisive for enzyme acivity, affects the responsiveness of young and old FAs (y-FAs and o-FAs) to activation of nitric-oxide/soluble-guanylate-cyclase/protein-kinase-G cascade (NO/sGC/PKG). Contractile responses of the vessels were measured by wire myography.
View Article and Find Full Text PDFThe hormone renin is produced in the kidney by the juxtaglomerular cells. It is the rate-limiting factor in the circulating renin-angiotensin-aldosterone system (RAAS), which contributes to electrolyte, water, and blood pressure homeostasis. In the kidneys, the distal tubule and the collecting duct are the key target segments for RAAS.
View Article and Find Full Text PDFA major shortcoming in the treatment of mesangial cell-associated diseases such as IgA nephropathy, diabetic nephropathy, or lupus nephritis, which frequently progress to end-stage renal disease, is poor drug availability in the glomerular mesangium. Drug delivery active targeting of nanoparticles, using ligands attached to the particle surface for target cell recognition to increase the biodistribution to the mesangium, is a promising strategy to overcome this hurdle. However, although several glomerular tissue targeting approaches have been described, so far no study has demonstrated the particles' ability to deliver sufficient drug amounts combined with an appropriate nanoparticle target retention time to trigger relevant biological effects in the mesangium.
View Article and Find Full Text PDFIn the Triple to Double Coincidence Ratio method in Liquid Scintillation Counting, the detection efficiency is calculated from the value of a free parameter describing the intrinsic light yield of the counting system. This model is generally based on a Poisson distribution of the number of photoelectrons detected and the detection efficiency is obtained from the complement of the non-detection efficiency. In the classical free parameter model, the mean of the Poisson distribution, m, is a constant but some variability of this mean could be expected from optical effects due to internal reflections inside the LS source or from non-homogeneity of the detection efficiency of the photomultiplier tubes.
View Article and Find Full Text PDF