Repeated therapeutic plasma exchange (TPE) procedures using centrifugation techniques became a standard therapy in some diseases. As the new device Spectra Optia (SPO; Terumo BCT) was available, we studied its performances in repeated procedures in 20 patients in three apheresis units. First we analysed the performance results obtained by SPO.
View Article and Find Full Text PDFBackground: Studies comparing cell components of blood and graft sources are very scarce. We present here a thorough study examining the cellular content of various sources of blood and cell therapy products.
Study Design And Methods: We have prospectively compared by fluorescence-activated cell sorting analyses the cellular composition of three blood sources on the one hand--peripheral blood (PB; n = 10) versus granulocyte-colony-stimulating factor (G-CSF)-mobilized PB (GCSF-PB, n = 10) versus cord blood (CB, n = 10)--and of three graft sources on the other hand--unmanipulated bone marrow (uBM, n = 5) versus leukapheresis product (LP, n = 10) versus thawed CB graft (n = 7).
Background: Cord Blood (CB) are increasingly used as an alternative stem cells source in adults for allogeneic Stem Cell Transplantation (allo-SCT). The risk of human herpesvirus (HHV-6) reactivation is significantly higher after CB transplant vs unrelated peripheral blood stem cells (PBSC) allo-SCT. Higher HHV-6 cell receptor CD46 expression on progenitor cells in CB may explain this difference.
View Article and Find Full Text PDF