Radiat Prot Dosimetry
December 2019
The paper describes a method of pulse height spectrum measurement in a wide energy range. The LVR‑15 research reactor building was chosen to demonstrate this method. Pulse height spectra were measured on the third floor of the reactor building.
View Article and Find Full Text PDFThe neutron flux distribution behind a reactor pressure vessel (RPV) is an important parameter that is monitored to determine neutron fluence in the RPV. Together with mechanical testing of surveillance specimens, these are the most important parts of in-service inspection programs that are essential for a realistic and reliable assessment of the RPV residual lifetime. The fast neutron fluence values are determined by a calculation.
View Article and Find Full Text PDFThe reliability of Fricke gel dosimeters in form of layers for measurements aimed at the characterization of epithermal neutron beams has been studied. By means of dosimeters of different isotopic composition (standard, containing (10)B or prepared with heavy water) placed against the collimator exit, the spatial distribution of gamma and fast neutron doses and of thermal neutron fluence are attained. In order to investigate the accuracy of the results obtained with in-air measurements, suitable MC simulations have been developed and experimental measurements have been performed utilizing Fricke gel dosimeters, thermoluminescence detectors and activation foils.
View Article and Find Full Text PDFGamma dose and thermal neutron fluence in a phantom exposed to an epithermal neutron beam for boron neutron capture therapy (BNCT) can be measured by means of a single thermoluminescence dosemeter (TLD-700). The method exploits the shape of the glow curve (GC) and requires the gamma-calibration GC (to obtain gamma dose) and the thermal-neutron-calibration GC (to obtain neutron fluence). The method is applicable for BNCT dosimetry in case of epithermal neutron beams from a reactor because, in most irradiation configurations, thermal neutrons give a not negligible contribution to the TLD-700 GC.
View Article and Find Full Text PDFSuitable dosimeter methods have been proposed and tested, to measure the different dose contributions in small phantoms exposed to epithermal/thermal neutron beams designed for BNCT. One method is based on Fricke-gel dosimeter in small tubes of 2.8mm of external diameter, that allow determining profiles of gamma dose and of boron dose.
View Article and Find Full Text PDF