Alternative bearings allow for the increased utilization of large femoral heads in total hip arthroplasty. This study demonstrated the effect of increasing femoral head size on the force required for dislocation during intraoperative assessment. Using a standard posterior approach, 10 cadaver hips underwent total hip arthroplasty; components were implanted in a standard fashion.
View Article and Find Full Text PDFBackground: Cigarette smoke exposure during prenatal and early postnatal periods increases the incidence of a variety of abnormal behaviors later in life. The purpose of this study was to identify the possible critical period of susceptibility to cigarette smoke exposure and evaluate the possibe effects of cigarette smoke during early life on brain-derived neurotrophic factor/neurotrophic tyrosine kinase receptor B signaling in the brain.
Methods: Three different age of imprinting control region mice were exposed to cigarette smoke or filtered air for 10 consecutive days beginning on either gestational day 7 by maternal exposure, or postnatal days 2 or 21 by direct inhalation.
Am J Orthop (Belle Mead NJ)
February 2015
Loss of fixation of the Synthes 13-hole femoral Less-Invasive Stabilization System (LISS) plate has been noted. The biomechanical stability of this plate may be affected by improper proximal placement. We conducted a study to determine if there is any difference in fixation failure, deformation, or stiffness based on proximal placement.
View Article and Find Full Text PDFObjectives: Reducing unnecessary radiation exposure from medical imaging is paramount. This study assessed whether a laser aiming guide for C-arm fluoroscopy reduced the number of exposures needed to obtain an acceptable image, thereby reducing total fluoroscopy time for hip, knee, and ankle fluoroscopy.
Methods: An obese cadaver was placed supine on a radiolucent surgical table.
The purpose of this study was to determine the minimum number of throws needed for knot security for square knots using 5 common suture materials and 3 common sizes by in vitro single load to failure biomechanical testing. The hypothesis was that each suture combination studied would share a common minimum of at least 5 throws to guarantee security. Five suture materials (FiberWire [Arthrex, Inc, Naples, Florida], Monosof, Surgipro, Maxon, and Polysorb [Covidien, Mansfield, Massachusetts]) with varying suture sizes (#5, #2, 0, 2-0, and 4-0) were tied in vitro, varying the number of square knot throws (3, 4, 5, and 6).
View Article and Find Full Text PDF