Capturing extreme surface velocities with >50 km/s dynamic range, which arise in shock physics such as inertial confinement fusion (ICF), is beyond the reach of conventional photon Doppler velocimetry (PDV) systems due to the need for extremely large electrical bandwidth under such conditions. The recent ignition in ICF calls for new velocimetry that can measure velocities exceeding 100 km/s. Time lens PDV (TL-PDV) is a solution where the high frequency beat signal from a conventional PDV system is periodically temporally magnified in the optical domain using a time lens.
View Article and Find Full Text PDFMicroneedle arrays are minimally invasive devices that have been extensively investigated for the transdermal/intradermal delivery of drugs/bioactives. Here, we demonstrate the release of bioactive molecules (estradiol, melatonin and meropenem) from poly(2-hydroxyethyl methacrylate), pHEMA, hydrogel-based microneedle patches in vitro. The pHEMA hydrogel microneedles had mechanical properties that were sufficiently robust to penetrate soft tissues (exemplified here by phantom tissues).
View Article and Find Full Text PDFBackground: In wind instrument performance, there is a constant contact between the player and the instrument, during which microorganisms in the mouth flora of the player are transferred into the instrument. The inner surface of the brass instruments provides the perfect environment for microorganisms to grow. As a result, players repeatedly interact with these micro-organisms during playing.
View Article and Find Full Text PDFThe release of metformin, a drug used in the treatment of cancer and diabetes, from poly(2-hydroxyethyl methacrylate), pHEMA, hydrogel-based microneedle patches is demonstrated in vitro. Tuning the composition of the pHEMA hydrogels enables preparation of robust microneedle patches with mechanical properties such that they would penetrate skin (insertion force of a single microneedle to be ≈40 N). Swelling experiments conducted at 20, 35, and 60 °C show temperature-dependent degrees of swelling and diffusion kinetics.
View Article and Find Full Text PDFReal-time and on-site food spoilage monitoring is still a challenging issue to prevent food poisoning. At the onset of food spoilage, microbial and enzymatic activities lead to the formation of volatile amines. Monitoring of these amines with conventional methods requires sophisticated, costly, labor-intensive, and time consuming analysis.
View Article and Find Full Text PDF