The heat transferred through protective clothing under long wave radiation compared to a reference condition without radiant stress was determined in thermal manikin experiments. The influence of clothing insulation and reflectivity, and the interaction with wind and wet underclothing were considered. Garments with different outer materials and colours and additionally an aluminised reflective suit were combined with different number and types of dry and pre-wetted underwear layers.
View Article and Find Full Text PDFThe purpose of this study was to investigate the effect of moisture on the heat transfer through clothing in relation to the water vapour resistance, type of underwear, location of the moisture and climate. This forms part of the work performed for work package 2 of the European Union THERMPROTECT project. Thermal manikin results of dry and wet heat loss are presented from different laboratories for a range of 2-layer clothing with similar dry insulations but different water vapour permeabilities and absorptive properties.
View Article and Find Full Text PDFIn order to assess the non-evaporative components of the reduced thermal insulation of wet clothing, experiments were performed with a manikin and with human subjects in which two layers of underwear separated by an impermeable barrier were worn under an impermeable overgarment at 20 degrees C, 80% RH and 0.5 ms(-1) air velocity. By comparing manikin measurements with dry and wetted mid underwear layer, the increase in heat loss caused by a wet layer kept away from the skin was determined, which turned out to be small (5-6 W m(-2)), irrespective of the inner underwear layer being dry or wetted, and was only one third of the evaporative heat loss calculated from weight change, i.
View Article and Find Full Text PDFJ Appl Physiol (1985)
January 2008
Investigating claims that a clothed person's mass loss does not always represent their evaporative heat loss (EVAP), a thermal manikin study was performed measuring heat balance components in more detail than human studies would permit. Using clothing with different levels of vapor permeability and measuring heat losses from skin controlled at 34 degrees C in ambient temperatures of 10, 20, and 34 degrees C with constant vapor pressure (1 kPa), additional heat losses from wet skin compared with dry skin were analyzed. EVAP based on mass loss (E(mass)) measurement and direct measurement of the extra heat loss by the manikin due to wet skin (E(app)) were compared.
View Article and Find Full Text PDFCold protective clothing was studied in 2 European Union projects. The objectives were (a) to examine different insulation calculation methods as measured on a manikin (serial or parallel), for the prediction of cold stress (IREQ); (b) to consider the effects of cold protective clothing on metabolic rate; (c) to evaluate the movement and wind correction of clothing insulation values. Tests were carried out on 8 subjects.
View Article and Find Full Text PDF