The operational suitability of electromagnetic starters equipped with experimental contacts has been substantiated within their use in electrical installations of the agro-industrial sector, which may be affected by the environments containing aggressive components. Tests on commutation wear resistance and investigations on arc erosion of the series-produced contact parts of such starters as PML-1100O4, PML-2100O4 (versions A and B; contact material-CpH-90, CpM-0,2 + M1, KMK-A10m, respectively) and PML-1100O4 starter with the experimental copper-based contact parts (Cu + Nb + Zr + YO; Cu + Mo + MoO + C + Ni; Cu + Cr + TiB + Nb + C + Zr) have been conducted. The influence of energy parameters of a commutated circuit on the value of electro-erosion wear, the morphology of the working surfaces of contacts and contact resistance have been determined.