Background: Sickle cell disease (SCD) is a group of hemoglobinopathies with a common point mutation causing the production of sickle cell hemoglobin (HbS). In high-throughput newborn screening (NBS) for SCD, a two-step procedure is suitable, in which qPCR first pre-selects relevant samples that are differentiated by a second method.
Methods: Three NBS centers using qPCR-based primary screening for SCD performed a laboratory comparison.
Sickle Cell Disease (SCD) is an increasing global health problem and presents significant challenges to European health care systems. Newborn screening (NBS) for SCD enables early initiation of preventive measures and has contributed to a reduction in childhood mortality from SCD. Policies and methodologies for NBS vary in different countries, and this might have consequences for the quality of care and clinical outcomes for SCD across Europe.
View Article and Find Full Text PDFObjective: 17-Hydroxyprogesterone (17-OHP) screening for classical congenital adrenal hyperplasia (CAH) is part of many newborn screening programs worldwide. Cut-off values are relatively high, and screening sensitivity does not reach 100%. Recently, the glucocorticoid receptor (GR) N363S-variant has been linked to relatively low degree of virilization and comparatively lower 17-OHP serum concentrations in clinically diagnosed female CAH patients.
View Article and Find Full Text PDFBackground: Blood samples for neonatal screening for inborn errors of metabolism are collected and shipped on standardized filter paper cards. Occasionally these samples are contaminated with EDTA, which is often used for anticoagulation. EDTA may interfere with newborn screening tests based on lanthanide fluorescence and thus lead to false-negative or false-positive results.
View Article and Find Full Text PDFBackground: False-positive and false-negative results occur in current newborn-screening programs for hepatorenal tyrosinemia, which measure tyrosine concentrations in blood spots, sometimes in combination with other metabolites, including succinylacetone. We present our experience with a newly described method for succinylacetone quantification in routine newborn screening.
Methods: Succinylacetone was extracted from blood spots that had already been extracted with absolute methanol for acylcarnitine and amino acid analysis.
In this study we have sequenced peptides eluted from a truncated recombinant HLA-A*6602 molecule, and compared their features with data reported for peptides presented in the A*6601 molecule. A striking change in the amino-acid binding preferences was observed at peptide position P1, which interacts with pocket A of the HLA peptide-binding region. For A*6601, aspartic acid and glutamic acid, both of which possess polar acidic side-chains, have been described as auxiliary anchors.