Purpose: to quantify the soft tissue dimensional changes after single-gap implant placement, during healing abutment and crown delivery phase for butt-joint and conical implant-abutment connection type.
Methods: forty patients were enrolled in the study and received randomly allocated implants with butt-joint and conical implant-abutment connection type. A standard healing abutment was placed after 6 months for two weeks.
The study investigated the impact of aging on surface roughness, color stability, and biocompatibility of hybrid resin-ceramic materials. A total of 225 specimens were produced from three three-dimensional (3D)-printed (HarzLabs Dental Sand Pro (HL), BEGO VarseoSmile Crown plus (BV), Voco V-Print c&b temp (VV)) and one milled material (Voco Grandio Blocs (VG)). Specimens were grouped into untreated, polished, and glazed surfaces.
View Article and Find Full Text PDFZh Nevrol Psikhiatr Im S S Korsakova
November 2024
Objective: To assess the frequency of geriatric syndromes (GS) and their relationship with vitamin B deficiency in elderly patients.
Material And Methods: The study included 222 people aged 60 years and older, 78.8% were women admitted to the geriatric ward as planned.
The purpose of this study was to evaluate the vertical bone loss after using different techniques: sloped implants or standard implants with guided bone regeneration. Patients with tooth gap and horizontal bone deficiency were randomly allocated to the test group (implants with sloped platform-SLP) and control group (standard design implants with guided bone regeneration-GBR). The primary outcome was bone loss (6 months after finishing the prosthetic treatment).
View Article and Find Full Text PDFThe aim of this study is to investigate the influence of printing material, build angle, and artificial aging on the accuracy of SLA- and DLP-printed occlusal devices in comparison to each other and to subtractively manufactured devices. A total of 192 occlusal devices were manufactured by one SLA-printing and two DLP-printing methods in 5 different build angles as well as milling. The specimens were scanned and superimposed to their initial CAD data and each other to obtain trueness and precision data values.
View Article and Find Full Text PDFObjectives: To investigate the impact of a centrifugation method on the surface characteristics, flexural properties, and cytotoxicity of an additively manufactured denture base polymer.
Methods: The tested specimens were prepared by digital light processing (DLP). A centrifugation method (CENT) was used to remove the residual uncured resin.
Objectives: The present study aims to examine the influence of the build angle on the accuracy (trueness and precision) of 3D printed crowns, table-tops and veneers with a hybrid resin-ceramic material.
Methods: One crown, on table-top and one veneer were printed in five different build angles (0°, 30°, 45°, 60°, 90°) (n = 50) with the digital light processing (DLP) system (Varseo XS, Bego) using hybrid resin (Varseo Smile Crown A3, Bego). All printed restorations were scanned using the laboratory scanner (D2000, 3Shape) and matched onto the initial reference design in metrology software (Geomagic Control X, 3D Systems).
Objectives: To investigate the influence of material and printing orientation on wear resistance and flexural properties of one low force SLA- and two DLP-printed splint materials and to compare these 3D-printed splints to a subtractively manufactured splint material.
Methods: Two DLP-printed (V-Print splint, LuxaPrint Ortho Plus) and one low force SLA-printed (Dental LT Clear) material, where specimens were printed in three printing orientations (0°, 45°, 90°), were investigated. In addition, one milled splint material (Zirlux Splint Transparent) was examined.
This longitudinal study aimed to evaluate facial growth and soft tissue changes in infants with complete unilateral cleft lip, alveolus, and palate (CUCLAP) at ages 3, 9, and 12 months. Using 3D images of 22 CUCLAP infants, average faces and distance maps for the entire face and specific regions were created. Color-coded maps highlighted more significant soft tissue changes from 3 to 9 months than from 9 to 12 months.
View Article and Find Full Text PDFAim: The adjustment and transfer of a stable occlusion can be a major challenge in prosthetic rehabilitations. The aim of the present study was to assess a noninvasive treatment option for complex prosthetic rehabilitations and occlusal analyses using 3D-printed restorations clinically.
Materials And Methods: Eleven patients received a partial or complete rehabilitation with the aid of 3D-printed restorations (n = 171).
Objective: The gold standard for a soft tissue augmentation around implants is a subepithelial connective tissue graft (CTG), but the xenogeneic collagen matrices (XCM) started to be used as an alternative. This systematic review aimed to assess the effectiveness XCM in comparison to CTG for the increasing the thickness of the soft tissue around implants.
Data: All studies included at least two parallel groups comparing the use of CTG and XCM with a minimum follow-up of 3 months.
To date, no scientific data is available regarding the development and radiographic assessment of approximal caries development after the insertion of 3D-printed, non-invasive veneers of different restoration thicknesses. For the present study, non-invasive veneers were fabricated from two different materials for printing and milling (Vita Enamic and VarseoSmile Crown plus). Three different restoration thicknesses (0.
View Article and Find Full Text PDFPurpose: To investigate the effects of printing-layer thickness and build angle on the surface characteristics and microbial adhesion of denture base polymers manufactured by digital light processing (DLP).
Methods: Specimens were additively manufactured using DLP. The specimens were printed with different printing-layer thicknesses (25, 50, and 100 μm) and build angles (0°, 45°, and 90°).
Objectives: To investigate the effect of a protective coating on the surface characteristics, flexural properties, cytotoxicity, and microbial adhesion of vat-photopolymerization additive-manufacturing denture base polymers.
Methods: The specimens were additively manufactured using digital light processing (DLP). Specimen surfaces were coated with the same printed resin, and mechanical polishing was used for comparison.
Background: ceramic veneers, crowns, and other types of restorations are often made using either the press heating technique or the subtractive method. The advent of lithography-based ceramic manufacturing (LCM) allows for the manufacturing of such restorations in an additive way.
Methods: this concept paper describes the first clinical experience in the application of LCM lithium disilicate restorations in vivo for the manufacturing of classic veneers for a patient with severe tooth wear.
Statement Of Problem: How much skin surface details of facial prostheses can be transferred throughout the digital production chain has not been quantified.
Purpose: The purpose of this in vitro study was to quantify the amount of skin surface details transferred from the prosthesis virtual design through the prototype printing with various additive manufacturing (AM) methods to the definitive silicone prosthesis with an indirect mold-making approach.
Material And Methods: Twelve test blocks with embossed wrinkles of 0.
Background: A combination of facial and intraoral scans produces a fully digitalized virtual patient. This concept allows for a 3D smile design and individualized virtual articulator application, which makes the rehabilitation outcome more predictable in terms of esthetics and function.
Case Presentation: In the present clinical case, the patient was 'digitalized' with the use of facial and intraoral scans.
Int J Environ Res Public Health
December 2021
A multilayer mouth guard is known to have the best protective performance. However, its manufacturing in a digital workflow may be challenging with regards to virtual design and materialization. The present case demonstrates a pathway to fabricate a multilayer individualized mouth guard in a fully digital workflow, which starts with intraoral scanning.
View Article and Find Full Text PDFObjectives: This in vitro study compares the scanning accuracy of various stationary and portable as well as extra- and intraoral devices for capturing oncological defects.
Methods: A 3D-printed model of a nasal, orbital, and auricular defect, as well as one of an intact auricle, were digitalized (n = 7 per device) with a stationary optical scanner (Pritiface), a portable extraoral optical scanner (Artec Space Spider), two intraoral scanners (Trios 4 and Primescan), and a smartphone (iPhone 11 Pro). For the reference data, the defect models were digitalized using a laboratory scanner (D2000).
Objectives: To investigate the influence of additive manufacturing method and build angle on surface characteristics and Candida albicans (C. albicans) adhesion to 3D printed denture base polymers.
Methods: Specimens of 3D printing denture base polymers were prepared by two printers, namely, stereolithography (SLA, Form 3B) and digital light processing technology (DLP, Solflex 350 plus).
Purpose: To assess the bonding between conventional and additively manufactured silicone elastomers and cylindrical retention titanium magnets for anchorage of facial prostheses.
Methods: The customized titanium retention magnets were embedded in conventional and additively produced silicone blocks without primer application (n = 20) and with two commercially available primers G611 (n = 20) and A304 (n = 20) applied onto the magnet surface. The pull out test was performed in the universal testing machine using 45° and 90° angulation and the pull out strength was measured for each group.
The fabrication of a non-metal clasp removable partial denture (RPD) using polymethylmethacrylate in a fully digital workflow has been reported. According to some studies, the polyamide material may be alternatively used for this purpose. The authors are unaware of any reports concerning the additive manufacturing of polyamide.
View Article and Find Full Text PDFDifferent approaches for digital workflows have already been presented for their use in palatal plates for newborns and infants. However, there is no evidence on the accuracy of CAD/CAM manufactured orthodontic appliances for this kind of application. This study evaluates trueness and precision provided by different CAM technologies and materials for these appliances.
View Article and Find Full Text PDFWhen applying a digital workflow, custom artificial resin teeth have to be integrated into a milled complete denture base, using polymethylmethacrylate (PMMA) applied with a powder-liquid technique. Debonding of denture teeth from dentures is reported to be a frequent complication. No evidence is provided as to which method of surface treatment may enhance the bonding strength.
View Article and Find Full Text PDFThe topical literature lacks any comparison between stereolithography (SLA) and direct light processing (DLP) printing methods with regard to the accuracy of complete denture base fabrication, thereby utilizing materials certified for this purpose. In order to investigate this aspect, 15 denture bases were printed with SLA and DLP methods using three build angles: 0°, 45° and 90°. The dentures were digitalized using a laboratory scanner (D2000, 3Shape) and analyzed in analyzing software (Geomagic Control X, 3D systems).
View Article and Find Full Text PDF