Arterioscler Thromb Vasc Biol
December 2024
Background: Chronic mental stress accelerates atherosclerosis through complicated neuroimmune pathways, needing for advanced imaging techniques to delineate underlying cellular mechanisms. While histopathology, ex vivo imaging, and snapshots of in vivo images offer promising evidence, they lack the ability to capture real-time visualization of blood cell dynamics within pulsatile arteries in longitudinal studies.
Methods: An electrically tunable lens was implemented in intravital optical microscopy, synchronizing the focal plane with heartbeats to follow artery movements.
Two-photon microscopy (TPM) is an attractive biomedical imaging method due to its large penetration depth and optical sectioning capability. In particular, label-free autofluorescence imaging offers various advantages for imaging biological samples. However, relatively low intensity of autofluorescence leads to low signal-to-noise ratio (SNR), causing practical challenges for imaging biological samples.
View Article and Find Full Text PDF[This corrects the article on p. 5452 in vol. 12, PMID: 34692194.
View Article and Find Full Text PDFOptical microscopy has been widely used in biomedical research as it provides photophysical and photochemical information of the target in subcellular spatial resolution without requiring physical contact with the specimen. To obtain a deeper understanding of biological phenomena, several efforts have been expended to combine such optical imaging modalities into a single microscope system. However, the use of multiple light sources and detectors through separated beam paths renders previous systems extremely complicated or slow for in vivo imaging.
View Article and Find Full Text PDFMultimodal nonlinear microscopy has been widely applied in biology and medicine due to its relatively deep penetration into tissue and its label-free manner. However, current multimodal systems require the use of multiple sources and detectors, leading to bulky, complex, and expensive systems. In this Letter, we present a novel method of using a single light source and detector for nonlinear multimodal imaging of biological samples.
View Article and Find Full Text PDFA fluorescence lifetime imaging microscopy (FLIM) integrated with two-photon excitation technique was developed. A wavelength-tunable femtosecond pulsed laser with nominal pulse repetition rate of 76-MHz was used to acquire FLIM images with a high pixel rate of 3.91 MHz by processing the pulsed two-photon fluorescence signal.
View Article and Find Full Text PDF