Annu Int Conf IEEE Eng Med Biol Soc
July 2015
The robustness of a model-based control protocol as a less intensive TGC protocol using insulin Glargine for provision of basal insulin is simulated in this study. To quantify the performance and robustness of the protocol to errors, namely physiological variability and sensor errors, an in-silico Monte Carlo analysis is performed. Actual patient data from Christchurch Hospital, New Zealand were used as virtual trial patients.
View Article and Find Full Text PDF