A triple isotope dilution GC-ICPMS method for the determination of tributyltin (TBT) was developed and validated to meet the European Water Framework Directive (WFD) requirements. The validation procedure involved the evaluation of trueness, precision (repeatability, intermediate precision), limit of detection (LOD) and limit of quantification (LOQ), stability, measurement uncertainty and traceability studies. The method is one of the most sensitive methods published to date with good accuracy, 103% average recovery in the range with %RSDs of 2.
View Article and Find Full Text PDFInclusion complex of naphthalene with methyl-beta-cyclodextrin in water has been formed. The aqueous solutions of the various amounts of Cove Mnsalts have been added to naphthalene-methyl-beta-cyclodextrin (NAP-Me-β-CD) inclusion complexes. Fluorescence properties of the naphthalene (NAP) compound have been utilized to observe the changes in fluorescence intensities.
View Article and Find Full Text PDFMar Pollut Bull
August 2013
In this study, we report results concerning the accumulation of heavy metals in seawater from Izmit Bay. The bay was divided into the three parts: the eastern, the central and the western basins. The goal of this study was to determine levels of heavy metals at various depths in the bay between April 2008 and May 2010.
View Article and Find Full Text PDFThe main objective of this study was to test water samples collected from 10 locations in the Dilovası area (a town in the Kocaeli region of Turkey) for heavy metal contamination and to classify the heavy metal (Cr, Mn, Co, Ni, Cu, Zn, As, Cd, Pb and Hg) contents in water samples using chemometric methods. The heavy metals in the water samples were identified using inductively coupled plasma-mass spectrometry (ICP-MS). To ascertain the relationship among the water samples and their possible sources, the correlation analysis, principal component analysis (PCA), and cluster analysis (CA) were used as classification techniques.
View Article and Find Full Text PDFJ Environ Sci Health A Tox Hazard Subst Environ Eng
July 2005
An accurate, fast, and simple method for determination of thallium in environmental water samples with Zeeman electrothermal atomic absorption spectrometry (ZETAAS) by previous flotation preconcentration is given. The possibility of using cobalt(III) hexamethylenedithiocarbamate as a colloidal precipitate collector for simultaneous flotation separation of Tl(I) and Tl(III) from water matrices was studied. All experimental parameters influencing a proper flotation of both thallium ions were ascertained.
View Article and Find Full Text PDF